background image

5 Operation

Operation manual

12

ATXM20~3 ATXM5 ATXM20~35R5V1B

Daikin room air conditioner

3P485919-12S – 2020.06

To delete all reservations

Use this function if you want to delete all reservations for all days of
the week in one go. This procedure CANNOT be used in the setting
mode.

1

Hold 

 for about 5 seconds while in the default display.

Result: 

All reservations will be deleted.

5.11

Wireless LAN connection

The customer is responsible for providing:

▪ Smartphone or tablet with minimum supported version of Android

or iOS, specified on 

http://www.onlinecontroller.daikineurope.com

▪ Internet line and communication device, such as a modem, router,

etc.

▪ Wireless LAN access point

▪ Installed free Daikin Residential Controller application

5.11.1

Precautions when using the wireless LAN

Do NOT use near:

Medical  equipment.

  E.g.  persons  using  cardiac  pacemakers  or

defibrillators. 

This 

product 

may 

cause 

electromagnetic

interference.

Auto-control  equipment.

  E.g.  automatic  doors  or  fire  alarm

equipment.  This  product  may  cause  faulty  behaviour  of  the
equipment.

Microwave oven.

 It may affect wireless LAN communications.

5.11.2

To install the Daikin Residential Controller
application

1

Open:

▪ Google Play for appliances using Android.
▪ App Store for appliances using iOS.

2

Search for Daikin Residential Controller.

3

Follow the directions on the screen to install.

5.11.3

To set the wireless connection

There  are  two  options  to  connect  the  wireless  adapter  with  your
smart device.

Connect the wireless LAN to your smart device directly.

Connect the wireless LAN to your home network. 

The wireless

LAN  will  communicate  with  your  smart  device  in  your  home
network using a modem, router or a similar device.

For more information and FAQ refer to:

http://www.onlinecontroller.daikineurope.com/

.

1

Stop operation before setting the wireless connection.

2

Use the user interface to select the wireless LAN setting menu.

Note: 

  Always  aim  the  user  interface  at  the  signal  receiver  on  the

unit when operating the user interface.

Menu

Description

Connection status check

WPS connection setting

AP mode/RUN mode (SSID + KEY) connection
setting

Reset to factory default

Wireless LAN OFF

To confirm the wireless LAN connection status

1

On  home  screen  menu,  press  and  hold 

  for  at  least

5 seconds while the unit is not operating.

Result: 

The  SP  (wireless  connection  setting  menu)  appears. 

is blinking.

(5 sec.) 

2

Press 

 to confirm the selection.

Result: 

 is blinking.

3

Check the operation and timer LEDs on the indoor unit display.

ON/

OFF

a

b

a

Operation LED

b

Timer LED

If operation
LED…

…and timer LED… …then wireless LAN is…

blinks

blinks

not connected

is off

blinks in 0.5 second
interval

running and ready to connect
to the home network via WPS
button on the router.

is off

blinks in 1 second
interval

▪ connected  to  the  home

network via SSID + KEY.

or

▪ connected  to  the  home

network via WPS button on
the router.

4

Press 

 to exit the menu.

Result: 

The display will return to the default screen.

To connect the wireless LAN to your home
network

The wireless adapter can be connected to your home network using
the:

WPS

 button on the router (if present),

SSID

 and 

KEY

 number located on the unit.

To connect using the WPS button

1

On  home  screen  menu,  hold 

  for  at  least  5  seconds  while

the unit is not operating.

Result: 

The SP menu   appears.   is blinking.

2

Change  to  the  SP  menu 

  by  pressing 

  once  or 

repeatedly.

(5 sec.) 

3

Press 

 to confirm the selection.

Summary of Contents for Siesta ATX-R

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner ATXM20R2V1B ATXM20R5V1B ATXM25R2V1B ATXM25R5V1B ATXM35R2V1B ATXM35R5V1B ATXM50R2V1B...

Page 2: ...less LAN connection 12 5 11 1 Precautions when using the wireless LAN 12 5 11 2 To install the Daikin Residential Controller application 12 5 11 3 To set the wireless connection 12 6 Energy saving and...

Page 3: ...rted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible chemical symbols are P...

Page 4: ...erant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside the system is odourl...

Page 5: ...door unit display ON OFF a b c d e a Signal receiver for user interface b Operation lamp c Timer lamp d Intelligent eye lamp e ON OFF button ON OFF button If the user interface is missing you can use...

Page 6: ...Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position 5 Operation 5 1 Operation range Use the system in the following temperature and humidi...

Page 7: ...32 C 10 30 C 18 30 C Note When using drying or fan only mode you cannot adjust the temperature 4 Press to stop operation Result disappears from the LCD The operation lamp goes off 5 3 Airflow rate 1...

Page 8: ...so may lead to malfunction Do NOT place large objects near the Intelligent eye sensor INFORMATION Powerful or Night set operation CANNOT be used at the same time with Intelligent eye operation The las...

Page 9: ...MATION The high speed electrons are generated and go away inside the unit to ensure safe operation The Streamer discharge may generate a fizzing sound If the airflow becomes weak the Streamer discharg...

Page 10: ...30 25 C 27 C 25 C 22 00 1 2 3 4 ON OFF ON OFF Saturday No timer setting Sunday Make up to 4 settings 8 00 10 00 19 00 21 00 27 C 27 C 25 C ON OFF OFF ON 1 2 3 4 ON ON ON ON setting Enables scheduling...

Page 11: ...Press to complete the setting Result is displayed on the LCD Note To change the reservation setting after copying refer to 5 10 1 To set Weekly timer operation 410 5 10 3 To confirm reservations You...

Page 12: ...l communicate with your smart device in your home network using a modem router or a similar device For more information and FAQ refer to http www onlinecontroller daikineurope com 1 Stop operation bef...

Page 13: ...ing 2 Change to the SP menu by pressing twice or repeatedly 2 5 sec 3 Hold for at least 2 seconds to confirm the selection Result is blinking The operation and timer LEDs are blinking at the same time...

Page 14: ...GWP value of the refrigerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING The refrigerant inside the unit is mildly flammable but normally does NOT le...

Page 15: ...a soft cloth If it is difficult to remove stains use water or a neutral detergent 7 4 To remove the front panel 1 Hold the front panel by the panel tabs on both sides and open it 2 Remove the front p...

Page 16: ...Silver allergen removal air purifying filter 1 set KAF057A41 7 8 To re install the front panel 1 Attach the front panel Align the shafts with the slots and push them all the way in 2 Close the front p...

Page 17: ...ioner 3P485919 12S 2020 06 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislat...

Page 18: ......

Page 19: ......

Page 20: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P485919 12S 2020 06 Copyright 2...

Reviews: