background image

5 Operation

Operation manual

9

ATXM20~3 ATXM5 ATXM20~35R5V1B
Daikin room air conditioner
3P485919-12S – 2020.06

INFORMATION

▪ Powerful and Econo operation CANNOT be used at the

same time. The last selected function takes priority.

▪ Econo  operation  reduces  power  consumption  of  the

outdoor  unit  by  limiting  the  rotation  speed  of  the
compressor.  If  power  consumption  is  already  low,
Econo  operation  will  NOT  further  reduce  power
consumption.

5.7.2

Outdoor unit quiet operation

Use  Outdoor  unit  quiet  operation  when  you  want  to  decrease  the
noise level of the outdoor unit. 

Example: 

At night.

INFORMATION

▪ Powerful and Outdoor unit quiet operation CANNOT be

used at the same time. The last selected function takes
priority.

▪ This  function  is  only  available  in  Automatic,  Cooling,

and Heating operation.

▪ Outdoor unit quiet operation limits the rotation speed of

the compressor. If the rotation speed of compressor is
already  low,  Outdoor  unit  quiet  operation  will  NOT
further reduce the compressor rotation speed.

5.7.3

To start/stop Econo and Outdoor unit
quiet operation

1

Press 

 one or more times.

Result: 

The setting will change as follows.

Display

Operation

Econo

Outdoor unit quiet

+

Econo and Outdoor unit quiet

Both deactivated

2

To  stop  operation,  press 

  until  both  symbols  disappear

from the LCD.

Note: 

Econo  operation  can  be  only  set  when  the  unit  is  running.

Pressing 

 cancels the setting and 

 disappears from the LCD.

Note: 

  remains  on  the  LCD,  even  if  you  turn  off  the  unit  using

the user interface or indoor unit ON/OFF switch.

5.8

Flash Streamer (air cleaning)
operation

Streamer  generates  a  high-speed  electron  stream  with  a  high
oxidizing  power,  reducing  bad  odours.  Together  with  the  titanium
apatite  deodorising  filter,  silver  allergen  removal  air  purifying  filter
and the air filters, this function cleans the air in the room.

INFORMATION

▪ The  high-speed  electrons  are  generated  and  go  away

inside the unit to ensure safe operation.

▪ The Streamer discharge may generate a fizzing sound.

▪ If  the  airflow  becomes  weak,  the  Streamer  discharge

may stop temporarily to prevent ozone smell.

5.8.1

To start/stop Flash Streamer (air cleaning)
operation

Prerequisite: 

Make sure the unit is operating (

 is displayed on

the user interface LCD).

1

Press 

.

Result: 

 is displayed on the LCD and the air in the room is

cleaned when the unit is operating.

2

To stop operation, press 

.

Result: 

 disappears from the LCD and operation stops.

5.9

OFF/ON timer operation

Timer  functions  are  useful  for  automatically  switching  the  air
conditioner off/on at night or in the morning. You can also use OFF
timer and ON timer in combination.

INFORMATION

Program the timer again in case of:

▪ A breaker has turned the unit off.

▪ A power failure.

▪ After replacing batteries in the user interface.

INFORMATION

The  clock  MUST  be  set  correctly  before  using  any  timer
functions. Refer to 

"4.3 To set the clock" 

[

4

 6].

5.9.1

To start/stop OFF timer operation

1

Press 

 to start.

Result: 

 is displayed on the LCD and 

 blinks.   and

the day of the week disappear from the LCD.

2

Press 

 or 

 to change the time setting.

3

Press 

 again.

Result: 

 and the set time are displayed on the LCD.

Result: 

The timer lamp lights up.

INFORMATION

Each  time 

  or 

  is  pressed,  the  time  setting

advances  by  10  minutes.  Holding  the  button  down  will
change the setting rapidly.

4

To stop operation, press 

.

Result: 

  and 

  disappear  from  the  LCD  and  the  timer

lamp goes off.   and the day of the week are displayed on the LCD.

INFORMATION

When you set the ON/OFF timer, the time setting is stored
in  the  memory.  The  memory  will  be  reset  when  the  user
interface batteries are replaced.

Use of night set mode in combination with OFF timer

The  air  conditioner  automatically  adjusts  the  temperature
setting  (0.5°C  up  in  cooling,  2.0°C  down  in  heating)  to
prevent 

excessive 

cooling/heating 

and 

ensure 

a

comfortable sleeping temperature.

5.9.2

To start/stop ON timer operation

1

Press 

 to start.

Summary of Contents for Siesta ATX-R

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner ATXM20R2V1B ATXM20R5V1B ATXM25R2V1B ATXM25R5V1B ATXM35R2V1B ATXM35R5V1B ATXM50R2V1B...

Page 2: ...less LAN connection 12 5 11 1 Precautions when using the wireless LAN 12 5 11 2 To install the Daikin Residential Controller application 12 5 11 3 To set the wireless connection 12 6 Energy saving and...

Page 3: ...rted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible chemical symbols are P...

Page 4: ...erant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside the system is odourl...

Page 5: ...door unit display ON OFF a b c d e a Signal receiver for user interface b Operation lamp c Timer lamp d Intelligent eye lamp e ON OFF button ON OFF button If the user interface is missing you can use...

Page 6: ...Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position 5 Operation 5 1 Operation range Use the system in the following temperature and humidi...

Page 7: ...32 C 10 30 C 18 30 C Note When using drying or fan only mode you cannot adjust the temperature 4 Press to stop operation Result disappears from the LCD The operation lamp goes off 5 3 Airflow rate 1...

Page 8: ...so may lead to malfunction Do NOT place large objects near the Intelligent eye sensor INFORMATION Powerful or Night set operation CANNOT be used at the same time with Intelligent eye operation The las...

Page 9: ...MATION The high speed electrons are generated and go away inside the unit to ensure safe operation The Streamer discharge may generate a fizzing sound If the airflow becomes weak the Streamer discharg...

Page 10: ...30 25 C 27 C 25 C 22 00 1 2 3 4 ON OFF ON OFF Saturday No timer setting Sunday Make up to 4 settings 8 00 10 00 19 00 21 00 27 C 27 C 25 C ON OFF OFF ON 1 2 3 4 ON ON ON ON setting Enables scheduling...

Page 11: ...Press to complete the setting Result is displayed on the LCD Note To change the reservation setting after copying refer to 5 10 1 To set Weekly timer operation 410 5 10 3 To confirm reservations You...

Page 12: ...l communicate with your smart device in your home network using a modem router or a similar device For more information and FAQ refer to http www onlinecontroller daikineurope com 1 Stop operation bef...

Page 13: ...ing 2 Change to the SP menu by pressing twice or repeatedly 2 5 sec 3 Hold for at least 2 seconds to confirm the selection Result is blinking The operation and timer LEDs are blinking at the same time...

Page 14: ...GWP value of the refrigerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING The refrigerant inside the unit is mildly flammable but normally does NOT le...

Page 15: ...a soft cloth If it is difficult to remove stains use water or a neutral detergent 7 4 To remove the front panel 1 Hold the front panel by the panel tabs on both sides and open it 2 Remove the front p...

Page 16: ...Silver allergen removal air purifying filter 1 set KAF057A41 7 8 To re install the front panel 1 Attach the front panel Align the shafts with the slots and push them all the way in 2 Close the front p...

Page 17: ...ioner 3P485919 12S 2020 06 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislat...

Page 18: ......

Page 19: ......

Page 20: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P485919 12S 2020 06 Copyright 2...

Reviews: