5 Operation

Operation manual

10

ATXM20~3 ATXM5 ATXM20~35R5V1B

Daikin room air conditioner

3P485919-12S – 2020.06

Result: 

 is displayed on the LCD and 

 blinks.   and

the day of the week disappear from the LCD.

2

Press 

 or 

 to change the time setting.

3

Press 

 again.

Result: 

  and  the  set  time  are  displayed  on  the  LCD.  The  timer

lamp lights up.

INFORMATION

Each  time 

  or 

  is  pressed,  the  time  setting

advances  by  10  minutes.  Holding  the  button  down  will
change the setting rapidly.

4

To stop operation, press 

.

Result: 

 and 

 disappear from the LCD and the timer

lamp goes off.   and the day of the week are displayed on the
LCD.

5.9.3

To combine OFF timer and ON timer

1

To  set  the  timers,  refer  to 

"5.9.1  To  start/stop  OFF  timer

operation" 

[

4

  9]  and 

"5.9.2  To  start/stop  ON  timer

operation" 

[

4

 9].

Result: 

 and 

 are displayed on the LCD.

Example:

Display

Current time

Set while…

Operation

6:00

the unit is
operating.

Stops at 7:00
and starts at
14:00.

the unit is NOT
operating.

Starts at 14:00.

Note: 

 If the timer setting is active, the current time is NOT displayed

on the LCD.

5.10

Weekly timer operation

With this operation, you can save up to 4 timer settings for each day
of the week.

Example: 

Create  a  different  setting  from  Monday  to  Friday  and  a

different setting for weekends.

Day of the week

Setting example

Monday

▪ Make up to 4 settings.

6:00

8:30

17:30

25°C

27°C

25°C

22:00

1

2

3

4

ON

OFF

ON

OFF

Tuesday~Friday

▪ Use the copy mode if the

settings are the same as
for Monday.

6:00

8:30

17:30

25°C

27°C

25°C

22:00

1

2

3

4

ON

OFF

ON

OFF

Saturday

▪ No timer setting

Sunday

▪ Make up to 4 settings.

8:00 10:00

19:00 21:00

27°C

27°C

25°C

ON

OFF

OFF

ON

1

2

3

4

ON-ON-ON-ON  setting.

  Enables  scheduling  the  operation  mode

and set temperature.

OFF-OFF-OFF-OFF setting.

 Only the turn off time can be set for

each day.

Note: 

 Be sure to aim the user interface at the indoor unit and check

for a receiving tone when setting the Weekly timer operation.

INFORMATION

The  clock  MUST  be  set  correctly  before  using  any  timer
functions. Refer to 

"4.3 To set the clock" 

[

4

 6].

INFORMATION

▪ Weekly timer and OFF/ON timer operation CANNOT be

used  at  the  same  time.  The  OFF/ON  timer  operation
takes priority. Weekly timer will be in standby, 
disappears  from  the  LCD.  When  the  OFF/ON  timer  is
completed, the Weekly timer becomes active.

▪ The  day  of  the  week,  OFF/ON  timer  mode,  time  and

temperature  (only  for  ON  timer)  can  be  set  with  the
Weekly timer. Other settings are based on previous ON
timer setting.

5.10.1

To set Weekly timer operation

1

Press 

.

Result: 

The day of the week and the reservation number of the

current day are displayed.

2

Press 

  or 

  to  select  the  day  of  the  week  and  the

reservation number.

3

Press 

.

Result: 

The day of the week is set. 

 and 

 blink.

4

Press 

 or 

 to select the mode.

Result: 

The setting will change as follows:

Display

Feature

ON timer

OFF timer

Blank

Deletes reservation

5

Press 

.

Result: 

The OFF/ON timer mode is set. 

 and the time

blink.

Note: 

Press 

  to  return  to  the  previous  screen.  If  blank  is

selected, continue to step 9.

6

Press 

  or 

  to  select  the  time.  The  time  can  be  set

between 0:00~23:50 in 10-minute intervals.

7

Press 

.

Result: 

The  time  is  set  and 

  and  the  temperature

blink.

Summary of Contents for Siesta ATX-R

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner ATXM20R2V1B ATXM20R5V1B ATXM25R2V1B ATXM25R5V1B ATXM35R2V1B ATXM35R5V1B ATXM50R2V1B...

Page 2: ...less LAN connection 12 5 11 1 Precautions when using the wireless LAN 12 5 11 2 To install the Daikin Residential Controller application 12 5 11 3 To set the wireless connection 12 6 Energy saving and...

Page 3: ...rted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible chemical symbols are P...

Page 4: ...erant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside the system is odourl...

Page 5: ...door unit display ON OFF a b c d e a Signal receiver for user interface b Operation lamp c Timer lamp d Intelligent eye lamp e ON OFF button ON OFF button If the user interface is missing you can use...

Page 6: ...Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position 5 Operation 5 1 Operation range Use the system in the following temperature and humidi...

Page 7: ...32 C 10 30 C 18 30 C Note When using drying or fan only mode you cannot adjust the temperature 4 Press to stop operation Result disappears from the LCD The operation lamp goes off 5 3 Airflow rate 1...

Page 8: ...so may lead to malfunction Do NOT place large objects near the Intelligent eye sensor INFORMATION Powerful or Night set operation CANNOT be used at the same time with Intelligent eye operation The las...

Page 9: ...MATION The high speed electrons are generated and go away inside the unit to ensure safe operation The Streamer discharge may generate a fizzing sound If the airflow becomes weak the Streamer discharg...

Page 10: ...30 25 C 27 C 25 C 22 00 1 2 3 4 ON OFF ON OFF Saturday No timer setting Sunday Make up to 4 settings 8 00 10 00 19 00 21 00 27 C 27 C 25 C ON OFF OFF ON 1 2 3 4 ON ON ON ON setting Enables scheduling...

Page 11: ...Press to complete the setting Result is displayed on the LCD Note To change the reservation setting after copying refer to 5 10 1 To set Weekly timer operation 410 5 10 3 To confirm reservations You...

Page 12: ...l communicate with your smart device in your home network using a modem router or a similar device For more information and FAQ refer to http www onlinecontroller daikineurope com 1 Stop operation bef...

Page 13: ...ing 2 Change to the SP menu by pressing twice or repeatedly 2 5 sec 3 Hold for at least 2 seconds to confirm the selection Result is blinking The operation and timer LEDs are blinking at the same time...

Page 14: ...GWP value of the refrigerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING The refrigerant inside the unit is mildly flammable but normally does NOT le...

Page 15: ...a soft cloth If it is difficult to remove stains use water or a neutral detergent 7 4 To remove the front panel 1 Hold the front panel by the panel tabs on both sides and open it 2 Remove the front p...

Page 16: ...Silver allergen removal air purifying filter 1 set KAF057A41 7 8 To re install the front panel 1 Attach the front panel Align the shafts with the slots and push them all the way in 2 Close the front p...

Page 17: ...ioner 3P485919 12S 2020 06 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislat...

Page 18: ......

Page 19: ......

Page 20: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P485919 12S 2020 06 Copyright 2...

Reviews: