![background image](http://html.mh-extra.com/html/daikin/rzqg-l8y1-series/rzqg-l8y1-series_technical-data-manual_2460028016.webp)
• Outdoor Unit • RZQG-L(8)Y1
3
• Split - Sky Air • RZQG-L(8)Y1
14
3
Electrical data
3 - 1
Electrical Data
RZQG125-140L(8)Y1
FCQG125EVEB
RZQG125L8Y1B
17,9
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,106
1,1
FCQHG125FVEB
RZQG125L8Y1B
18,3
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,244
1,4
FCQG35FVEB
×4
RZQG125L8Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.044×4
0.3×4
FCQG50FVEB
×3
RZQG125L8Y1B
17,6
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.039×3
0.3×3
FCQG60FVEB
×2
RZQG125L8Y1B
17,3
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.044×2
0.3×2
FCQG125FVEB
RZQG125L8Y1B
17,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,168
1
FFQ35C2VEB
×4
RZQG125L8Y1B
18,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.05×4
0.4×4
FFQ50C2VEB
×3
RZQG125L8Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.05×3
0.4×3
FFQ60C2VEB
×2
RZQG125L8Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.05×2
0.6×2
FDXS35F2VEB
×4
RZQG125L8Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.034×4
0.3×4
FDXS50F2VEB9
x3
RZQG125L8Y1B
18,4
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.06x3
0.5x3
FDXS60F2VEB
×2
RZQG125L8Y1B
17,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.060×2
0.5×2
FBQ35C8VEB
×4
RZQG125L8Y1B
22,5
㸫
25
㸫
14,2
0.094+0.094
0.4+0.4
0.140×4
1.2×4
FBQ50C8VEB
×3
RZQG125L8Y1B
21,0
㸫
25
㸫
14,2
0.094+0.094
0.4+0.4
0.140×3
1.2×3
FBQ60C8VEB
×2
RZQG125L8Y1B
19,3
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.350×2
1.1×2
FBQ125C8VEB
RZQG125L8Y1B
19,1
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,350
2,1
FDQ125C7VEB
RZQG125L8Y1B
19,1
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,350
2,1
FVQ125CVEB
RZQG125L8Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,238
1,2
FHQ35CBVEB
x4
RZQG125L8Y1B
19,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,060 x 4
0,6 x 4
FHQ50CBVEB
x3
RZQG125L8Y1B
18,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,060 x 3
0,6 x 3
FHQ60CBVEB
x2
RZQG125L8Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,091 x 2
0,6 x 2
FHQ125CBVEB
RZQG125L8Y1B
18,4
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,150
1,5
FUQ125CVEB
RZQG125L8Y1B
18,3
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,106
1,4
FCQG71EVEB
×2
RZQG140L7Y1B
17,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.048×2
0.4×2
FCQG140EVEB
RZQG140L7Y1B
17,9
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,106
1,1
FCQHG71FVEB
×2
RZQG140L7Y1B
17,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.091×2
0.5×2
FCQHG140FVEB
RZQG140L7Y1B
18,3
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,244
1,4
FCQG35FVEB
×4
RZQG140L7Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.044×4
0.3×4
FCQG50FVEB
×3
RZQG140L7Y1B
17,6
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.039×3
0.3×3
FCQG71FVEB
×2
RZQG140L7Y1B
17,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.054×2
0.4×2
FCQG140FVEB
RZQG140L7Y1B
17,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,168
1
FFQ35C2VEB
×4
RZQG140L7Y1B
18,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.05×4
0.4×4
FFQ50C2VEB
×3
RZQG140L7Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.05×3
0.4×3
FDXS35F2VEB
×4
RZQG140L7Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.034×4
0.3×4
FDXS50F2VEB9
×4
RZQG140L7Y1B
18,4
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.06x3
0.5x3
FBQ35C8VEB
×4
RZQG140L7Y1B
22,5
㸫
25
㸫
14,2
0.094+0.094
0.4+0.4
0.140×4
1.2×4
FBQ50C8VEB
×3
RZQG140L7Y1B
21,0
㸫
25
㸫
14,2
0.094+0.094
0.4+0.4
0.140×3
1.2×3
FBQ71C8VEB
×2
RZQG140L7Y1B
19,3
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.350×2
1.1×2
FBQ140C8VEB
RZQG140L7Y1B
19,1
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,350
2,1
FHQ140CBVEB
RZQG140L7Y1B
18,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,150
1,8
FUQ71CVEB
x2
RZQG140L7Y1B
18,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,046 x 2 0,9 x 2
Symbols
MCA: Minimum Circuit Ampere [A]
TOCA: Total overcurrent amps [A]
MFA: Maximum Fuse Ampere [A]
MSC: Maximum current of the starting compressor [A]
RLA: Rated load amps [A]
OFM: Outdoor fan motor
IFM: Indoor fan motor
FLA: Full Load Ampere [A]
KW: Fan motor rated output [kW]
Notes
1. The RLA is based on the following conditions.
Cooling
Indoor temperature 27.0°C DB / 19.0°C WB
Outdoor temperature 35.0°C DB
Heating
Indoor temperature 20.0°C DB
Outdoor temperature 7.0°C DB / 6.0°C WB
2. TOCA is the total value of each overcurrent set.
3. Voltage range
The units are suitable for use with electrical systems in which the voltage supplied to the unit terminals is not below or above the listed range limits.
4. The maximum allowable voltage that is unbalanced between phases is 2%.
5. MCA is the maximum input current.
The capacity of the MFA must be greater than that of the MCA.
Select the MFA according to the table.
6. Select the wire size according to the MCA.
7. MFA is used to select the circuit breaker and the ground fault circuit interruptor.
Earth leakage circuit breaker
FLA
Compressor
OFM
IFM
Indoor
Outdoor
Power supply
Voltage
range
MCA
TOCA
MFA
MSC
RLA
kW
FLA
kW
3N~ 50Hz
380-415V
M
ini
m
um
: 342 V
M
ax
im
um
456 V
3N~ 50Hz
380-415V
M
inim
um
: 342 V
M
a
x
im
u
m
456 V
3D077810C