background image

• VRV

®

 Systems • Outdoor Units

21

• Outdoor Units • VRV

®

 Heat Pump • RXYSQ4-6PAY

6

Wiring diagram

6 - 

2

External connection diagram

3D057919

RXYSQ-PY1

Outdoor units

Power supply

Main switch

Switch

Fuse

2 wires cable

Power supply

Main

switch

(Transmission line)

2 wires cable

(Transmission line)

2 wires cable

(Transmission line)

2 wires cable

(Transmission line)

Switch

Switch

Fuse

Fuse

2 wires cable

2 wires cable

2 wires cable

(Power line)

(Power line)

(Power line)

Indoor units

2 wires cable

(Power line)

Switch

Switch

Fuse

Fuse

2 wires cable

(Power line)

Notes)

1

All wiring, components and materials to be produced on the site must comply with the applicable local and
national codes.

2

Use copper conductors only.

3

As for details, see wiring diagram.

4

Install circuit breakers for safety.

5

All field wiring and components must be installed by a licensed electrician.

6

The unit shall be grounded in compliance with the applicable local and national codes.

7

Wiring shown are general points-of-connection guides only and are not intended for or to include all details for
a specific installation.

8

Be sure to install the switch and the fuse to the power line of each equipment.

9

Install the main switch that can interrupt all power sources in an integrated manner because this system consists
of the equipment utilizing the multiple power sources.

10

If there exists the possibility of reversed phase, lose phase, momentary blackout or the power goes on and off
while the product is operating, attach a reversed phase protection circuit locally.
Running the product in reversed phase may break the compressor and other parts.

EEDEN10-200_11_RXYSQ4-6P7Y1B.pdf   23

9/06/2010   13:14:46

Summary of Contents for RXYSQ4-6PAY

Page 1: ...RXYSQ4 6PAY E E D E N 1 0 2 0 0 Air Conditioners VRV Heat Pump Technical Data...

Page 2: ...RXYSQ4 6PAY E E D E N 1 0 2 0 0 Air Conditioners VRV Heat Pump Technical Data...

Page 3: ...ptions 5 3 Capacity tables 6 Cooling capacity tables 6 Heating capacity tables 12 4 Dimensional drawing centre of gravity 18 Dimensional drawing 18 Centre of gravity 18 5 Piping diagram 19 6 Wiring di...

Page 4: ...of Rows 2 2 2 Fin Pitch mm 2 2 2 Nr of Passes 10 10 10 Face Area m 1 131 Nr of Stages 60 60 60 Tube type Hi XSS 8 Fin Fin type Non symmetric waffle louvre Treatment Corrosion resistant Fan Type Prope...

Page 5: ...fety devices HPS Fan motor thermal protection Inverter overload protector PC board fuse Standard Accessories Standard Accessories Installation manual Quantity 1 1 1 Standard Accessories Operation manu...

Page 6: ...ns For Power Supply Quantity 5 5 5 Remark Earth wire included For connection with indoor Quantity 2 2 2 Remark F1 F2 Power Supply Intake Both indoor and outdoor unit Field earth leakage breaker mA 300...

Page 7: ...eat Pump RXYSQ4 6PAY 2 Options NOTES 1 All options are kits No Item RXYSQ4 RXYSQ5 RXYSQ6 1 Cool heat selector KRC19 26A6 2 Fixing box KJB111A 3 Refnet header KHRQ22M29H 4 Refnet joint KHRQ22M20T 5 Cen...

Page 8: ...03 13 4 3 36 13 8 3 45 14 1 3 47 14 4 3 50 33 9 07 1 99 10 8 2 57 12 6 3 23 13 4 3 56 13 5 3 57 13 9 3 60 14 2 3 63 35 9 07 2 12 10 8 2 74 12 6 3 45 13 2 3 69 13 3 3 70 13 7 3 74 14 0 3 77 37 9 07 2...

Page 9: ...10 4 1 50 18 5 29 0 74 6 31 0 88 7 33 1 03 7 84 1 11 8 35 1 19 9 37 1 36 10 4 1 53 20 5 29 0 75 6 31 0 90 7 33 1 05 7 84 1 13 8 35 1 22 9 37 1 39 10 4 1 57 21 5 29 0 76 6 31 0 91 7 33 1 06 7 84 1 15 8...

Page 10: ...78 16 0 3 86 16 3 3 87 16 7 3 91 17 1 3 94 33 11 3 2 49 13 5 3 21 15 6 3 98 15 8 4 00 16 0 4 02 16 4 4 06 16 8 4 09 35 11 3 2 65 13 5 3 43 15 3 4 13 15 5 4 15 15 8 4 17 16 2 4 20 16 6 4 24 37 11 3 2...

Page 11: ...13 0 1 87 18 6 61 0 93 7 89 1 10 9 16 1 29 9 80 1 39 10 4 1 49 11 7 1 70 13 0 1 91 20 6 61 0 94 7 89 1 12 9 16 1 32 9 80 1 42 10 4 1 52 11 7 1 73 13 0 1 96 21 6 61 0 95 7 89 1 13 9 16 1 33 9 80 1 43...

Page 12: ...4 62 17 1 4 65 17 3 4 67 17 8 4 71 18 2 4 76 33 12 6 3 21 15 0 4 15 16 6 4 80 16 8 4 82 17 1 4 84 17 5 4 89 18 0 4 94 35 12 6 3 42 15 0 4 42 16 4 4 97 16 6 5 00 16 8 5 02 17 3 5 07 17 7 5 12 37 12 6 3...

Page 13: ...5 14 4 2 42 18 7 32 1 19 8 73 1 42 10 1 1 67 10 9 1 80 11 6 1 92 13 0 2 19 14 4 2 47 20 7 32 1 21 8 73 1 45 10 1 1 70 10 9 1 83 11 6 1 96 13 0 2 23 14 4 2 54 21 7 32 1 23 8 73 1 46 10 1 1 72 10 9 1 85...

Page 14: ...11 16 0 3 81 15 0 3 52 14 5 3 38 14 0 3 25 13 1 2 98 9 0 7 9 16 9 3 94 16 0 3 66 15 0 3 39 14 5 3 25 14 0 3 12 13 1 2 86 11 0 9 8 16 9 3 79 16 0 3 52 15 0 3 26 14 5 3 13 14 0 3 01 13 1 2 76 13 0 11 8...

Page 15: ...87 3 21 9 31 2 99 8 75 2 78 8 47 2 67 8 19 2 57 7 63 2 36 9 5 10 9 87 3 12 9 31 2 91 8 75 2 70 8 47 2 60 8 19 2 50 7 63 2 30 8 5 9 1 9 87 3 04 9 31 2 83 8 75 2 63 8 47 2 53 8 19 2 44 7 63 2 24 7 0 7 6...

Page 16: ...89 19 5 4 99 19 2 4 96 18 6 4 76 18 0 4 57 16 7 4 19 9 0 7 9 20 2 4 95 20 2 5 05 19 2 4 77 18 6 4 58 18 0 4 39 16 7 4 03 11 0 9 8 20 8 5 01 20 4 4 96 19 2 4 59 18 6 4 41 18 0 4 23 16 7 3 89 13 0 11 8...

Page 17: ...0 12 6 4 52 11 9 4 21 11 2 3 91 10 8 3 76 10 5 3 61 9 76 3 33 9 5 10 0 12 6 4 39 11 9 4 09 11 2 3 80 10 8 3 65 10 5 3 51 9 76 3 24 8 5 9 1 12 6 4 28 11 9 3 99 11 2 3 71 10 8 3 57 10 5 3 43 9 76 3 16 7...

Page 18: ...89 19 9 5 01 19 9 5 12 19 8 5 18 19 8 5 24 18 8 4 96 9 0 7 9 20 6 4 96 20 5 5 07 20 5 5 19 20 5 5 24 20 2 5 20 18 8 4 77 11 0 9 8 21 2 5 03 21 2 5 13 21 1 5 24 20 9 5 22 20 2 5 01 18 8 4 60 13 0 11 8...

Page 19: ...0 14 0 5 21 13 4 4 99 12 6 4 63 12 2 4 45 11 8 4 28 11 0 3 94 9 5 10 0 14 2 5 20 13 4 4 84 12 6 4 50 12 2 4 33 11 8 4 16 11 0 3 83 8 5 9 1 14 2 5 07 13 4 4 72 12 6 4 39 12 2 4 22 11 8 4 06 11 0 3 74 7...

Page 20: ...RE RXYSQ6PA7V1B 19 1 BRAZING RXYSQ4PA7Y1B 15 9 FLARE RXYSQ5PA7Y1B 15 9 FLARE RXYSQ6PA7Y1B 19 1 BRAZING 1 Gas pipe connection A 2 Liwuid connection pipe 9 5 flare 3 Service Port in the unit 2x 4 Electr...

Page 21: ...Filter Filter Filter Filter Pressure regulating valve High pressure switch 4 way valve Solenoid valve Accumulator Electronic expansion valve Electronic expansion valve Low pressure sensor Capillary tu...

Page 22: ...PH Pressure switch High A1P Printed circuit board main K5R K6R Magnetic relay V1R Power module A2P Printed circuit board inv L1R Reactor V2R V3R Diode module BS1 BS5 Push button switch Mode set return...

Page 23: ...details see wiring diagram 4 Install circuit breakers for safety 5 All field wiring and components must be installed by a licensed electrician 6 The unit shall be grounded in compliance with the appli...

Page 24: ...t is normally over the set value due to enviromental noise and sound reflection approximate threshold hearing for continuous noise Scale A 52 Scale C 63 5 4D057921 Octave band sound pressure level dB...

Page 25: ...allation conditions it is normally over the set value due to enviromental noise and sound reflection approximate threshold hearing for continuous noise Scale A 53 0 Scale C 64 5 4D057925 Octave band s...

Page 26: ...10E 12W m2 3 Measured according to ISO 3744 3TW29237 3 Sound power level dB Octave band center frequency Hz RXYSQ5PY1 NOTES 1 dBA A weighted sound power level A scale according to IEC 2 Reference aco...

Page 27: ...is higher than the unit There is no height limit for obstructions on the intake side 2 Series installation 2 or more Pattern 1 2 Series installation 2 or more Obstacle on both sides b Obstacle above t...

Page 28: ...s follows L A L H 0 L 1 2 H 750 1 2 H L H 1000 H L Set the stand as L H The relations between H A and L are as follows L A L H 0 L 1 2 H 1000 1 2 H L H 1250 H L Set the stand as L H Pattern 2 Where th...

Page 29: ...re CDB Range for operation Range for pull down operation Outdoor temperature CWB Range for operation Indoor temp CWB Indoor temp CDB Notes These figures assume the following operating conditions Indoo...

Page 30: ......

Page 31: ...t This challenge demands the eco design and development of a wide range of products and an energy management system resulting in energy conservation and a reduction of waste VRV products are not withi...

Reviews: