Check the following before requesting 

service

NOTE :

Check the above items, and if the problem still cannot be fixed, contact your dealer for repair, stating the symptom(s) and 
the model name.

Symptom

If the display “        ” (INSPECTION), 

UNIT No.” and the OPERATION 

lamp flash and “MALFUNCTION 

CODE” appears.

Action and contact

Inform your dealer of the contents of the display on the remote contoller.

C

H

UNIT No.

OPERATION lamp

INDOOR UNIT No. in which a malfunction occurs

MALFUNCTION CODE

INSPECTION

display

Safety equipment such as fuses, 

circuit breakers, leakage breaker, etc. 

are set off occasionally.

Operating switch function is not secure.
Water leaks from the air conditioner.

Do not set power switch to on.

Set power switch to off.                 
Stop operation.

Symptom

The machine does not work at all.

The machine runs but stops soon.

The machine does not work 

properly.

y

d

e

m

e

R

e

s

u

a

C

Blocked air inlet or air outlet of indoor 
or outdoor unit

Blown fuse or open breaker

Power outage

If the main power supply is turned off 
during operation, operation will restart 
automatically after power turns back again.

Replace the fuse or close the breaker.

Blocked air inlet or air outlet of the 
indoor or outdoor unit

Remove the obstacle.

Improper temperature setting

Low fan speed setting

Improper air flow direction
Window or door open

Direct sunshine

Too many people in the room

Too many heat sources in the room
If the air filter clogged.

Remove the obstacle.

See page 8.
See page 9.

See page 11.

Close.
Put up a curtain or blind over the window.

Refer to the instruction manual of 
the indoor unit, and clean the air filter.

17

Summary of Contents for RXYMQ3AV4A

Page 1: ...RXYMQ3AV4A RXYMQ4AV4A RXYMQ5AV4A RXYMQ6AVE RXYMQ8AY1 RXYMQ4AVE RXYMQ5AVE RXYMQ6AV4A RXYMQ3AVE OPERATION MANUAL System air conditioner RXYMQ9AY1...

Page 2: ......

Page 3: ...ing the manual file it away for future reference READ BEFORE OPERATION Safety precaution 1 Names of parts 4 Preparation Before Operation 7 Useful Information 7 OPERATION COOLING HEATING FAN Operation...

Page 4: ...anship may result in water leakage electric shocks or fire hazards Do not place objects including rods your fingers etc in the air inlet or outlet Injury may result due to contact with the air conditi...

Page 5: ...ditioner The use of any other power supply may cause heat generation fire or product failures Consult your dealer regarding cleaning the inside of the air conditioner Improper cleaning may cause break...

Page 6: ...ernal parts of the controller Do not remove the front panel Touching certain internal parts will cause electric shocks and damage to the unit Please consult your dealer about checking and adjustment o...

Page 7: ...uctions near the air outlet of the outdoor unit Obstructions may result in poor performance and increased operating noise If abnormal noise occur ask your dealer for advise Regarding wiring All wiring...

Page 8: ...26A 24 25 Remote Controller TEST C hr TEST NOT AVAILABLE OPTION L H hr 10 1 3 11 21 20 19 12 23 2 4 5 13 7 8 14 16 9 6 15 17 18 22 Fig 1 NOTE This manual describe only for BRC1C62 KRC19 26A For other...

Page 9: ...ton for SETTING TEMPERATURE of the thermostat FAN SPEED CONTROL button Press this button to select the fan speed LOW or HIGH of your choice PROGRAMMING TIME button Use this button for programming STAR...

Page 10: ...a long time Do not leave the door or window open The air will be released and the effect of cooling heating will be reduced Do not allow direct sunshine to enter the room during the cooling operation...

Page 11: ...Operation HEATING Operation FAN Operation 2 Press ON OFF button OPERATION lamp lights up and the system starts OPERATION FOR SYSTEMS WITH COOL HEAT CHANGEOVER REMOTE CONTROLLER Only for the heat pump...

Page 12: ...TING button is pressed then returned soon the air conditioner will start the operation automatically about 5 minutes later because the air conditioner is controlled so that excessive load is not appli...

Page 13: ...ON lamp lights up and system starts OPERATION FOR SYSTEMS WITH COOL HEAT CHANGEOVER REMOTE CONTROLLER Only for the heat pump 1 Select cooling operation mode with the cool heat changeover remote contro...

Page 14: ...o it may be different from the display The air flow direction can be adjusted in either of the following ways Automatic The air flow flap adjusts its position itself Fixed air flow direction The air f...

Page 15: ...set the time for stopping or starting the system When this button is pressed the time advances by 1 hour When this button is pressed the time goes backward by 1 hour 3 Press the TIMER ON OFF button T...

Page 16: ...e right to select the cooling heating operation mode master remote controller can select the cooling heating operation mode The displays of slave remote controllers show CHANGEOVER UNDER CONTROL and t...

Page 17: ...r in the sequence fan dry cooling heating The indication in other slave indoor unit is changed over while following up the indication in the master indoor unit PRECAUTIONS FOR GROUP CONTROL SYSTEM OR...

Page 18: ...s heard when the system stops after HEATING OPERATION Expansion and contraction of plastic parts caused by temperature change makes this noise A low Sah Choro choro sound is heard while an indoor unit...

Page 19: ...L When a long beep sound is issued in the case of wireless remote controller Refer to page 13 This is because cool heat changeover is controlled by the cool heat changeover remote control switch Ask y...

Page 20: ...power switch to off Stop operation Symptom The machine does not work at all The machine runs but stops soon The machine does not work properly y d e m e R e s u a C Blocked air inlet or air outlet of...

Page 21: ...room and contact your dealer After asking for repair of refrigerant leakage confirm to the service personnel that the leak ing positions are repaired securely then start the operation In certain opera...

Page 22: ...NOTES...

Page 23: ......

Page 24: ...3P344160 3G M14N096 HT http www daikin com global_ac...

Reviews: