background image

READ BEFORE OPERATION

Safety precaution

To gain full advantage of the air conditioner’s functions and to avoid malfunction due to mishandling, we recommend that 
you read this instruction manual carefully before use.

This air conditioner is classified under “appliances not accessible to the general public”.

The precautions described herein are classified as WARNING and CAUTION. They both contain important

information regarding safety. Be sure to observe all precautions without fail. 

 

After reading, keep this manual in a convenient place so that you can refer to it whenever necessary. If the 

equipment is transferred to a new user, be sure also to hand over the manual. 

WARNING

Failure to follow these instructions properly may result in 
personal injury or loss of life.

CAUTION

Failure to observe these instructions properly may result in 
property damage or personal injury, which may be serious 
depending on the circumstances.

WARNING

Be aware that prolonged, direct exposure to cool 

or warm air from the air conditioner, or to air that 
is too cool or too warm can be harmful to your 
physical condition and health.

When the air conditioner is malfunctioning (giving 
off a burning odour, etc.) turn off power to the unit 
and contact your local dealer.

Continued operation under such circumstances may 
result in a failure, electric shocks or fire hazards.

Consult your local dealer about installation work.

Doing the work yourself may result in water leakage, 
electric shocks or fire hazards.

Consult your local dealer regarding modification, 

repair and maintenance of the air conditioner.

Improper workmanship may result in water leakage, 

electric shocks or fire hazards.

Do not place objects, including rods, your fingers, 

etc., in the air inlet or outlet.

Injury may result due to contact with the air 

conditioner’s high speed fan blades.

Never touch the air outlet or the horizontal blades 

while the swing flap is in operation.

Fingers may become caught or the unit may break 

down.

Beware of fire in case of refrigerant leakage.

If the air conditioner is not operating correctly, i.e. not 

generating cool or warm air, refrigerant leakage could 
be the cause. 

Consult your dealer for assistance. 
The refrigerant within the air conditioner is safe and 

normally does not leak. 

However, in the event of a leakage, contact with a 

naked burner, heater or cooker may result in 
generation of noxious gas. 

Do not longer use the air conditioner until a qualified 

service person confirms that the leakage has been 
repaired.

Consult your local dealer regarding what to do in 

case of refrigerant leakage.

When the air conditioner is to be installed in a small 

room, it is necessary to take proper measures so that 

the amount of any leaked refrigerant does not exceed 

the concentration limit in the event of a leakage. 

Otherwise, this may lead to an accident due to oxygen 

depletion.

Contact professional personnel about attachment 

of accessories and be sure to use only 

accessories specified by the manufacturer.

If a defect results from your own workmanship, it may 

result in water leaks, electric shock or fire. 

Consult your local dealer regarding relocation and 

reinstallation of the air conditioner.

Improper installation work may result in leakage, 

electric shocks or fire hazards.

Read the precautions thoroughly to avoid misuse of the equipment.

There are two kinds of safety precaution and tips listed in the following.

1

Summary of Contents for RXYMQ3AV4A

Page 1: ...RXYMQ3AV4A RXYMQ4AV4A RXYMQ5AV4A RXYMQ6AVE RXYMQ8AY1 RXYMQ4AVE RXYMQ5AVE RXYMQ6AV4A RXYMQ3AVE OPERATION MANUAL System air conditioner RXYMQ9AY1...

Page 2: ......

Page 3: ...ing the manual file it away for future reference READ BEFORE OPERATION Safety precaution 1 Names of parts 4 Preparation Before Operation 7 Useful Information 7 OPERATION COOLING HEATING FAN Operation...

Page 4: ...anship may result in water leakage electric shocks or fire hazards Do not place objects including rods your fingers etc in the air inlet or outlet Injury may result due to contact with the air conditi...

Page 5: ...ditioner The use of any other power supply may cause heat generation fire or product failures Consult your dealer regarding cleaning the inside of the air conditioner Improper cleaning may cause break...

Page 6: ...ernal parts of the controller Do not remove the front panel Touching certain internal parts will cause electric shocks and damage to the unit Please consult your dealer about checking and adjustment o...

Page 7: ...uctions near the air outlet of the outdoor unit Obstructions may result in poor performance and increased operating noise If abnormal noise occur ask your dealer for advise Regarding wiring All wiring...

Page 8: ...26A 24 25 Remote Controller TEST C hr TEST NOT AVAILABLE OPTION L H hr 10 1 3 11 21 20 19 12 23 2 4 5 13 7 8 14 16 9 6 15 17 18 22 Fig 1 NOTE This manual describe only for BRC1C62 KRC19 26A For other...

Page 9: ...ton for SETTING TEMPERATURE of the thermostat FAN SPEED CONTROL button Press this button to select the fan speed LOW or HIGH of your choice PROGRAMMING TIME button Use this button for programming STAR...

Page 10: ...a long time Do not leave the door or window open The air will be released and the effect of cooling heating will be reduced Do not allow direct sunshine to enter the room during the cooling operation...

Page 11: ...Operation HEATING Operation FAN Operation 2 Press ON OFF button OPERATION lamp lights up and the system starts OPERATION FOR SYSTEMS WITH COOL HEAT CHANGEOVER REMOTE CONTROLLER Only for the heat pump...

Page 12: ...TING button is pressed then returned soon the air conditioner will start the operation automatically about 5 minutes later because the air conditioner is controlled so that excessive load is not appli...

Page 13: ...ON lamp lights up and system starts OPERATION FOR SYSTEMS WITH COOL HEAT CHANGEOVER REMOTE CONTROLLER Only for the heat pump 1 Select cooling operation mode with the cool heat changeover remote contro...

Page 14: ...o it may be different from the display The air flow direction can be adjusted in either of the following ways Automatic The air flow flap adjusts its position itself Fixed air flow direction The air f...

Page 15: ...set the time for stopping or starting the system When this button is pressed the time advances by 1 hour When this button is pressed the time goes backward by 1 hour 3 Press the TIMER ON OFF button T...

Page 16: ...e right to select the cooling heating operation mode master remote controller can select the cooling heating operation mode The displays of slave remote controllers show CHANGEOVER UNDER CONTROL and t...

Page 17: ...r in the sequence fan dry cooling heating The indication in other slave indoor unit is changed over while following up the indication in the master indoor unit PRECAUTIONS FOR GROUP CONTROL SYSTEM OR...

Page 18: ...s heard when the system stops after HEATING OPERATION Expansion and contraction of plastic parts caused by temperature change makes this noise A low Sah Choro choro sound is heard while an indoor unit...

Page 19: ...L When a long beep sound is issued in the case of wireless remote controller Refer to page 13 This is because cool heat changeover is controlled by the cool heat changeover remote control switch Ask y...

Page 20: ...power switch to off Stop operation Symptom The machine does not work at all The machine runs but stops soon The machine does not work properly y d e m e R e s u a C Blocked air inlet or air outlet of...

Page 21: ...room and contact your dealer After asking for repair of refrigerant leakage confirm to the service personnel that the leak ing positions are repaired securely then start the operation In certain opera...

Page 22: ...NOTES...

Page 23: ......

Page 24: ...3P344160 3G M14N096 HT http www daikin com global_ac...