background image

Table of contents

Installation manual

4

(A)RXP20~35N5V1B

R32 split series

3P650253-10H – 2022.10

Table of contents

1 About the documentation

4

1.1

About this document..................................................................

4

2 Specific installer safety instructions

4

3 About the box

6

3.1

Outdoor unit...............................................................................

6

3.1.1

To unpack the outdoor unit .........................................

6

3.1.2

To remove the accessories from the outdoor unit.......

7

4 Unit installation

7

4.1

Preparing the installation site ....................................................

7

4.1.1

Installation site requirements of the outdoor unit ........

7

4.1.2

Additional installation site requirements of the
outdoor unit in cold climates .......................................

7

4.2

Mounting the outdoor unit..........................................................

8

4.2.1

To provide the installation structure ............................

8

4.2.2

To install the outdoor unit............................................

8

4.2.3

To provide drainage ....................................................

8

4.2.4

To prevent the outdoor unit from falling over ..............

8

5 Piping installation

9

5.1

Preparing refrigerant piping .......................................................

9

5.1.1

Refrigerant piping requirements..................................

9

5.1.2

Refrigerant piping length and height difference ..........

9

5.1.3

Refrigerant piping insulation .......................................

9

5.2

Connecting the refrigerant piping ..............................................

9

5.2.1

About connecting the refrigerant piping ......................

9

5.2.2

Precautions when connecting the refrigerant piping ...

9

5.2.3

To connect the refrigerant piping to the outdoor unit ..

9

5.3

Checking the refrigerant piping .................................................

9

5.3.1

To check for leaks.......................................................

9

5.3.2

To perform vacuum drying .......................................... 10

6 Charging refrigerant

10

6.1

About charging refrigerant.........................................................

10

6.2

About the refrigerant..................................................................

10

6.3

To determine the additional refrigerant amount ........................

11

6.4

To determine the complete recharge amount ...........................

11

6.5

To charge additional refrigerant ................................................

11

6.6

To fix the fluorinated greenhouse gases label...........................

11

7 Electrical installation

11

7.1

Specifications of standard wiring components ..........................

12

7.2

To connect the electrical wiring to the outdoor unit ...................

12

8 Finishing the outdoor unit installation

12

8.1

To finish the outdoor unit installation.........................................

12

8.2

To close the outdoor unit...........................................................

12

9 Commissioning

12

9.1

Checklist before commissioning ................................................

12

9.2

Checklist during commissioning ................................................

13

9.3

To perform a test run .................................................................

13

9.4

Starting up the outdoor unit .......................................................

13

10 Troubleshooting

13

10.1

Fault diagnosis using LED on outdoor unit PCB .......................

13

11 Disposal

13

12 Technical data

14

12.1

Wiring diagram ..........................................................................

14

12.1.1

Unified wiring diagram legend..................................... 14

12.2

Piping diagram ..........................................................................

16

12.2.1

Piping diagram: Outdoor unit ...................................... 16

1

About the documentation

1.1

About this document

WARNING

Make  sure  installation,  servicing,  maintenance,  repair  and
applied  materials  follow  the  instructions  from  Daikin
(including  all  documents  listed  in  “Documentation  set”)
and, in addition, comply with applicable legislation and are
performed  by  qualified  persons  only.  In  Europe  and  areas
where  IEC  standards  apply,  EN/IEC  60335-2-40  is  the
applicable standard.

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised installers

INFORMATION

This  document  only  describes  installation  instructions
specific  to  the  outdoor  unit.  For  installation  of  the  indoor
unit  (mounting  the  indoor  unit,  connecting  the  refrigerant
piping to the indoor unit, connecting the electrical wiring to
the indoor unit …), see the installation manual of the indoor
unit.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the outdoor unit)

Outdoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the outdoor unit)

Installer reference guide:

▪ Preparation of the installation, reference data, …

▪ Format:  Digital  files  on 

https://www.daikin.eu

.  Use  the  search

function   to find your model.

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

Business Portal (authentication required).

2

Specific installer safety
instructions

Always observe the following safety instructions and regulations.

Unit installation (see 

"4 Unit installation"

 [

4

 7])

WARNING

Installation  shall  be  done  by  an  installer,  the  choice  of
materials  and  installation  shall  comply  with  the  applicable
legislation. In Europe, EN378 is the applicable standard.

Summary of Contents for RXP20N5V1B

Page 1: ...Installation manual R32 split series English Installation manual R32 split series RXP20N5V1B RXP25N5V1B RXP35N5V1B ARXP20N5V1B ARXP25N5V1B ARXP35N5V1B...

Page 2: ...sploatuojami laikantis m s instrukcij atbilst d m direkt v m vai regul m ja vien ie izstr d jumi tiek lietoti saska ar m su instrukcij m s v zhode s nasleduj cou imi smernicou ami alebo predpisom mi z...

Page 3: ...accordance with our instructions as amended S I 2016 1101 Electrical Equipment Safety Regulations 2016 S I 2016 1091 Electromagnetic Compatibility Regulations 2016 S I 2008 1597 Supply of Machinery Sa...

Page 4: ...cal data 14 12 1 Wiring diagram 14 12 1 1 Unified wiring diagram legend 14 12 2 Piping diagram 16 12 2 1 Piping diagram Outdoor unit 16 1 About the documentation 1 1 About this document WARNING Make s...

Page 5: ...n This will cause abnormal pressure in the refrigeration cycle which may result in equipment damage and even injury CAUTION Incomplete flaring may cause refrigerant gas leakage Do NOT re use flares Us...

Page 6: ...l insulation as such pipes will be very hot DANGER RISK OF ELECTROCUTION All electrical parts including thermistors are powered by the power supply Do NOT touch them with bare hands DANGER RISK OF ELE...

Page 7: ...installation servicing maintenance and repair comply with instructions from Daikin and with applicable legislation and are executed ONLY by authorised persons 4 1 1 Installation site requirements of t...

Page 8: ...a 100 mm above expected level of snow 4 2 2 To install the outdoor unit 4 M8 M10 4 2 3 To provide drainage NOTICE If the unit is installed in a cold climate take adequate measures so that the evacuat...

Page 9: ...sure the outdoor and indoor unit are mounted Typical workflow Connecting the refrigerant piping involves Connecting the refrigerant piping to the indoor unit Connecting the refrigerant piping to the...

Page 10: ...harging additional refrigerant make sure the outdoor unit s external refrigerant piping is checked leak test vacuum drying INFORMATION Depending on the units and or the installation conditions it migh...

Page 11: ...ying 1 Connect the refrigerant cylinder to the service port 2 Charge the additional refrigerant amount 3 Open the gas stop valve 6 6 To fix the fluorinated greenhouse gases label 1 Fill in the label a...

Page 12: ...220 240 V Recommended field fuse 16 A Earth leakage circuit breaker MUST comply with applicable legislation 7 2 To connect the electrical wiring to the outdoor unit 1 Remove the service cover 2 Open...

Page 13: ...run is finished set the temperature to a normal level In cooling mode 26 28 C in heating mode 20 24 C 3 The system stops operating 3 minutes after the unit is turned OFF INFORMATION Even if the unit i...

Page 14: ...tor D V D Diode DB Diode bridge DS DIP switch E H Heater FU F U for characteristics refer to PCB inside your unit Fuse FG Connector frame ground H Harness H P LED V L Pilot lamp light emitting diode S...

Page 15: ...llation manual 15 A RXP20 35N5V1B R32 split series 3P650253 10H 2022 10 Symbol Meaning X M Terminal strip block Y E Electronic expansion valve coil Y R Y S Reversing solenoid valve coil Z C Ferrite co...

Page 16: ...T 7 0CuT 9 5CuT M 6 4CuT 6 4CuT 4 8CuT 6 4CuT 9 5CuT 9 5CuT 9 5CuT 9 5CuT 9 5CuT 7 9CuT Propeller fan 9 5CuT 9 5CuT 7 0CuT g2 g1 f f c a b d j l k g3 i e RXP20N RXP25N ARXP20N ARXP25N h 7 0CuT 7 0CuT...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P650253 10H 2022 10 Copyright 2...

Reviews: