Precautions on Installation

• 

Check the strength and level of the installation surface so that the unit does not cause 

any operating vibrations or noise after installation.

• 

Fix the unit in place securely using foundation bolts, as in the figure. (Prepare 4 
sets of 5/16 inch (M8) or 3/8 inch (M10) foundation bolts, nuts and washers; all sold 
separately.)

• 

It is best to screw in the foundation bolts until their ends are 3/4 inch (20mm) from the 

foundation surface.

3/4”

(20mm)

Outdoor Unit Installation Diagram

RXM18

RXM24

Max. allowable piping length

98-1/2ft (30m)

** Min. allowable piping length

10ft (3m)

Max. allowable piping height

82ft (25m)

* Additional refrigerant required for refrigerant 

pipe exceeding 49-1/4ft (15m) in length.

0.22oz/ft (20g/m)

Gas pipe

O.D. 1/2 inch 

(12.7mm)

O.D. 5/8 inch 

(15.9mm)

Liquid pipe

O.D. 1/4 inch (6.4mm)

Refrigerant piping must be kept to a minimum.
  *  Be sure to add the proper amount of additional refrigerant. 

Failure to do so may result in reduced performance. 

**  The suggested shortest pipe length is 10ft (3m), in order to avoid 

noise from the outdoor unit and vibration. 
(Mechanical noise and vibration may occur depending on how 

the unit is installed and the environment in which it is used.)

Allow 11-13/16 (300) 

of work space below 
the ceiling surface.

4-15/16 (125)

(From unit’

s side)

23-5/8 (600)

(Foot bolt-hole centers)

13-5/8

(346)

(Foot bolt-hole 

 

centers)

unit : inch (mm)

If there is a danger of the unit falling or overturning, 

fix the unit with foundation bolts, or with wire or 

other means.

 

CAUTION

Keep the piping length between 

10ft (3m) and 98-1/2ft (30m). 

Refrigerant piping must be protected from 
physical damage.
Install a plastic cover or equivalent.

If strong wind blows into the air discharge 
side from the front and there is a danger 
that the fan may be damaged, change the  
orientation of the air discharge side of the  
outdoor unit or use an air direction 

adjustment grille (sold separately).

Wrap the insulation pipe with 

finishing tape from bottom to top.

9-13/16 (250) from w

all

Allow space for piping and 
electrical servicing.

 

„

How to remove the stop 

valve cover

1)  Remove the screw on the 

stop valve cover.

2)  Slide the stop valve cover 

downward to remove it.

 

„

How to attach the stop valve 

cover

1)  Insert the upper part of the 

stop valve cover into the 
outdoor unit.

2)  Tighten the screw.

Stop valve cover

In sites with poor drainage, use 
block bases for the outdoor unit.  
Adjust foot height until the unit is 
level. Otherwise, water leakage or 
pooling of water may occur.

Refrigerant charge label

Please fill in with indelible ink, 

 

„

1

 the factory refrigerant charge of the product, 

 

„

2

 the additional refrigerant amount charged in the field and

 

„

1

 + 

2

 the total refrigerant charge 

on the refrigerant charge label supplied with the product.

Affix the refrigerant charge label near the manufacturer’s label 
after filling it out.

The filled out label must be adhered in the 
proximity of the product charging port.

1

1

2

2

+ =

2

=

1

=

4

5

3

2

1

1   factory refrigerant charge of the 

product: see unit name plate 

2   additional refrigerant amount 

charged in the field 

3   total refrigerant charge 
4   outdoor  unit
5   refrigerant cylinder and manifold 

for charging

English

01_EN_3P686865-1.indd   4

2022/04/20   9:18:27

Summary of Contents for RXM18WVJU9

Page 1: ...l MODELS RXM18WVJU9 RXM24WVJU9 DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R32 Split Series Installation manual Manuel dinstallation Manual de instalaci n Manuel dinstallation 00_CV_3P686865 1 ind...

Page 2: ...lly in basements and an asphyxiation hazard could occur leading to serious injury or death Do not ground units to water pipes gas pipes telephone wires or lightning rods as incomplete grounding can ca...

Page 3: ...ensation Be careful when transporting the product Do not turn off the power immediately after stopping operation Always wait for at least 5 minutes before turning off the power Otherwise water leakage...

Page 4: ...Since water will flow from the drain of the outdoor unit do not place anything under the unit which must be kept away from moisture 9 A location where flammable gas does not leak Position at least 6...

Page 5: ...CAUTION Keep the piping length between 10ft 3m and 98 1 2ft 30m Refrigerant piping must be protected from physical damage Install a plastic cover or equivalent If strong wind blows into the air disch...

Page 6: ...t is recommended to either change the orientation of the outdoor unit outlet side or use the air direction adjustment grille sold separately Outdoor Unit Installation 1 Installing the outdoor unit Whe...

Page 7: ...020 inch 0 0 5mm 0 039 0 059 inch 1 0 1 5mm 0 059 0 079 inch 1 5 2 0mm Flaring 4 Refrigerant piping CAUTION Use the flare nut fixed to the main unit This is to prevent the flare nut from cracking as a...

Page 8: ...0mm Min O D 5 8 inch 15 9mm 1 15 16 inch 50mm or more 0 039 inch 1 0mm C1220T O I D 5 8 13 16 inch 16 20mm Liquid side O D 1 4 inch 6 4mm 1 3 16 inch 30mm or more 0 031 inch 0 8mm C1220T O I D 5 16 13...

Page 9: ...ifold and stop vacuum pumping Maintain this condition for a few minutes to make sure that the compound pressure gauge pointer does not swing back 1 6 Remove the valve caps from the liquid stop valve a...

Page 10: ...r connection to the power supply terminal block Place the round crimp style terminals on the wires up to the covered part and secure in place Round crimp style terminal Stranded wire Screw Flat washer...

Page 11: ...outdoor fan turning on and off when using facility settings Do not place humidifiers or other items which might raise the humidity in rooms where facility settings are being used A humidifier might c...

Page 12: ...alve and gas stop valve 2 Begin forced cooling operation 3 After 5 to 10 minutes close the liquid stop valve with a hexagonal wrench 4 After 2 to 3 minutes close the gas stop valve and stop forced coo...

Page 13: ...ks Incomplete cooling heating function Refrigerant gas and liquid pipes and indoor drain hose extension are thermally insulated Water leakage Draining line is properly installed Water leakage System i...

Page 14: ...The two dimensional bar code is a manufacturing code 3P686865 1 M21B537 2205 HT 00_CV_3P686865 1 indd 2 2022 02 10 16 42 47...

Reviews: