Piping Diagrams
SiBE041012
180
Appendix
1. Piping Diagrams
1.1
Indoor Unit
FTXG25/35JV1BW(S)
1.2
Outdoor Unit
RXG25/35J2V1B
INDOOR UNIT
6.4CuT
HEAT EXCHANGER
CROSS FLOW FAN
FIELD PIPING
6.4CuT
M
FAN MOTOR
FIELD PIPING
9.5CuT
9.5CuT
REFRIGERANT FLOW
COOLING
HEATING
THERMISTOR
ON HEAT EXCH.
4D065855
7.9CuT
(9.5CuT)
7.9CuT
7.0CuT
M
HEAT EXCHANGER
MUFFLER
6.4CuT
FIELD PIPING
9.5CuT
HEATING
6.4CuT
FIELD PIPING
9.5CuT
6.4CuT
MUFFLER
9.5CuT
REFRIGERANT FLOW
7.0CuT
COOLING
φ
.4.0
×
ID
. 2.0CuT
4.8CuT
PROPELLER FAN
COMPRESSOR
OUTDOOR UNIT
9.5CuT
(6.4CuT)
4.8CuT
9.5CuT
MUFFLER
ACCUMULATOR
9.5CuT
OUTDOOR TEMPERATURE
THERMISTOR
HEAT EXCHANGER
THERMISTOR
MOTOR OPERATED
VALVE
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
LIQUID STOP
VALVE
GAS STOP
VALVE
DISCHARGE PIPE
THERMISTOR
FOUR WAY
VALVE
ON:HEATING
3D059586E