SiBE041012
Indoor Unit
Removal Procedure
145
1.12 Removal of Vertical Blade ASSY
Procedure
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Unfasten the 3 hooks at
the shaft mounting part
by pressing them with a
flat screwdriver.
A vertical blade ASSY has 6
fins. It is impossible to
replace only one fin.
The vertical blade ASSY is
not marked for difference
between right and left.
2
Unfasten the hooks at
the upper 2 positions
with a flat screwdriver.
3
Remove the vertical
blade ASSY.
(R12154)
(R12155)
Vertical blade ASSY
(R12156)