Summary of Contents for RXA20A5V1B9

Page 1: ...ation manual R32 Split system air conditioners English Installation manual R32 Split system air conditioners RXA20A5V1B9 RXA25A5V1B9 RXA35A5V1B9 RXM20R5V1B9 RXM25R5V1B9 RXM35R5V1B9 ARXM25R5V1B9 ARXM35...

Page 2: ...bus eksploatuojami laikantis m s instrukcij atbilst d m direkt v m vai regul m ja vien ie izstr d jumi tiek lietoti saska ar m su instrukcij m s v zhode s nasleduj cou imi smernicou ami alebo predpiso...

Page 3: ...t the products are used in accordance with our instructions as amended S I 2008 1597 Supply of Machinery Safety Regulations 2008 S I 2016 1101 Electrical Equipment Safety Regulations 2016 S I 2016 109...

Page 4: ...run 13 11 Troubleshooting 13 11 1 Fault diagnosis using LED on outdoor unit PCB 13 12 Disposal 13 13 Technical data 13 13 1 Wiring diagram 13 13 1 1 Unified wiring diagram legend 13 1 About the docum...

Page 5: ...his would cause refrigerant gas leakage DANGER RISK OF EXPLOSION Do NOT open the stop valves before the vacuum drying is finished Charging refrigerant see 6 Charging refrigerant 49 WARNING The refrige...

Page 6: ...cing Install the switch box cover before turning ON the power supply Configuration see 9 Configuration 411 WARNING Before connecting or disconnecting the connector make sure the power supply is turned...

Page 7: ...against direct snowfall and take care that the outdoor unit is NEVER snowed up a b c c d a Snow cover or shed b Pedestal c Prevailing wind direction d Air outlet It is recommended to provide at least...

Page 8: ...and height difference What Distance Maximum allowable pipe length 20 m Minimum allowable pipe length 1 5 m Maximum allowable height difference 15 m 5 2 Connecting the refrigerant piping DANGER RISK O...

Page 9: ...lves after installing the refrigerant piping and performing vacuum drying Running the system with the stop valves closed may break the compressor 6 Charging refrigerant 6 1 About the refrigerant This...

Page 10: ...he GWP value mentioned on the refrigerant charge label 2 Fix the label on the inside of the outdoor unit near the gas and liquid stop valves 7 Electrical installation DANGER RISK OF ELECTROCUTION WARN...

Page 11: ...1 Remove the service cover 2 Open the wire clamp 3 Connect the interconnection cable and power supply as follows f 50 Hz 220 240 V a b c d e a Interconnection cable b Power supply cable c Circuit brea...

Page 12: ...saving connector 3 Turn ON the main power supply 10 Commissioning NOTICE General commissioning checklist Next to the commissioning instructions in this chapter a general commissioning checklist is als...

Page 13: ...r saving 2 Power supply fault 3 Turn the power OFF and back ON and check the LED within approximately 3 minutes If the LED is OFF again the outdoor unit PCB is faulty DANGER RISK OF ELECTROCUTION When...

Page 14: ...M Pulse amplitude modulation PCB Printed circuit board PM Power module PS Switching power supply PTC PTC thermistor Q Insulated gate bipolar transistor IGBT Q C Circuit breaker Q DI KLM Earth leak cir...