background image

Table of contents

Installation manual

4

RXA-A9, RXM-R9, ARXM-R9

R32 Split system air conditioners

3P650253-1S – 2022.11

Table of contents

1 About the documentation

4

1.1

About this document..................................................................

4

2 Specific installer safety instructions

4

3 About the box

6

3.1

Outdoor unit...............................................................................

6

3.1.1

To remove the accessories from the outdoor unit.......

6

4 Unit installation

6

4.1

Preparing the installation site ....................................................

6

4.1.1

Installation site requirements of the outdoor unit ........

6

4.1.2

Additional installation site requirements of the
outdoor unit in cold climates .......................................

7

4.2

Mounting the outdoor unit..........................................................

7

4.2.1

To provide the installation structure ............................

7

4.2.2

To install the outdoor unit............................................

7

4.2.3

To provide drainage ....................................................

7

5 Piping installation

8

5.1

Preparing refrigerant piping .......................................................

8

5.1.1

Refrigerant piping requirements..................................

8

5.1.2

Refrigerant piping insulation .......................................

8

5.1.3

Refrigerant piping length and height difference ..........

8

5.2

Connecting the refrigerant piping ..............................................

8

5.2.1

To connect the refrigerant piping to the outdoor unit ..

8

5.3

Checking the refrigerant piping .................................................

9

5.3.1

To check for leaks.......................................................

9

5.3.2

To perform vacuum drying ..........................................

9

6 Charging refrigerant

9

6.1

About the refrigerant..................................................................

9

6.2

To determine the additional refrigerant amount ........................

9

6.3

To determine the complete recharge amount ...........................

10

6.4

To charge additional refrigerant ................................................

10

6.5

To fix the fluorinated greenhouse gases label...........................

10

7 Electrical installation

10

7.1

Specifications of standard wiring components ..........................

11

7.2

To connect the electrical wiring to the outdoor unit ...................

11

8 Finishing the outdoor unit installation

11

8.1

To finish the outdoor unit installation.........................................

11

9 Configuration

11

9.1

Facility setting............................................................................

11

9.1.1

To set the facility mode ............................................... 11

9.2

Standby electricity saving function ............................................

12

9.2.1

About the standby electricity saving function .............. 12

9.2.2

To turn ON standby electricity saving function............ 12

10 Commissioning

12

10.1

Checklist before commissioning ................................................

12

10.2

Checklist during commissioning ................................................

13

10.3

To perform a test run .................................................................

13

11 Troubleshooting

13

11.1

Fault diagnosis using LED on outdoor unit PCB .......................

13

12 Disposal

13

13 Technical data

13

13.1

Wiring diagram ..........................................................................

13

13.1.1

Unified wiring diagram legend..................................... 13

1

About the documentation

1.1

About this document

WARNING

Make  sure  installation,  servicing,  maintenance,  repair  and
applied  materials  follow  the  instructions  from  Daikin
(including  all  documents  listed  in  “Documentation  set”)
and, in addition, comply with applicable legislation and are
performed  by  qualified  persons  only.  In  Europe  and  areas
where  IEC  standards  apply,  EN/IEC  60335-2-40  is  the
applicable standard.

Target audience

Authorised installers

INFORMATION

This  document  only  describes  installation  instructions
specific  to  the  outdoor  unit.  For  installation  of  the  indoor
unit  (mounting  the  indoor  unit,  connecting  the  refrigerant
piping to the indoor unit, connecting the electrical wiring to
the indoor unit …), see the installation manual of the indoor
unit.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the outdoor unit)

Outdoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the outdoor unit)

Installer reference guide:

▪ Preparation of the installation, reference data, …

▪ Format:  Digital  files  on 

https://www.daikin.eu

.  Use  the  search

function   to find your model.

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

Scan the QR code below to find the full documentation set and more
information about your product on Daikin website.

ARXM-R9

RXA-A9

RXM-R9

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

Business Portal (authentication required).

2

Specific installer safety
instructions

Always observe the following safety instructions and regulations.

Summary of Contents for RXA20A5V1B9

Page 1: ...ation manual R32 Split system air conditioners English Installation manual R32 Split system air conditioners RXA20A5V1B9 RXA25A5V1B9 RXA35A5V1B9 RXM20R5V1B9 RXM25R5V1B9 RXM35R5V1B9 ARXM25R5V1B9 ARXM35...

Page 2: ...bus eksploatuojami laikantis m s instrukcij atbilst d m direkt v m vai regul m ja vien ie izstr d jumi tiek lietoti saska ar m su instrukcij m s v zhode s nasleduj cou imi smernicou ami alebo predpiso...

Page 3: ...t the products are used in accordance with our instructions as amended S I 2008 1597 Supply of Machinery Safety Regulations 2008 S I 2016 1101 Electrical Equipment Safety Regulations 2016 S I 2016 109...

Page 4: ...run 13 11 Troubleshooting 13 11 1 Fault diagnosis using LED on outdoor unit PCB 13 12 Disposal 13 13 Technical data 13 13 1 Wiring diagram 13 13 1 1 Unified wiring diagram legend 13 1 About the docum...

Page 5: ...his would cause refrigerant gas leakage DANGER RISK OF EXPLOSION Do NOT open the stop valves before the vacuum drying is finished Charging refrigerant see 6 Charging refrigerant 49 WARNING The refrige...

Page 6: ...cing Install the switch box cover before turning ON the power supply Configuration see 9 Configuration 411 WARNING Before connecting or disconnecting the connector make sure the power supply is turned...

Page 7: ...against direct snowfall and take care that the outdoor unit is NEVER snowed up a b c c d a Snow cover or shed b Pedestal c Prevailing wind direction d Air outlet It is recommended to provide at least...

Page 8: ...and height difference What Distance Maximum allowable pipe length 20 m Minimum allowable pipe length 1 5 m Maximum allowable height difference 15 m 5 2 Connecting the refrigerant piping DANGER RISK O...

Page 9: ...lves after installing the refrigerant piping and performing vacuum drying Running the system with the stop valves closed may break the compressor 6 Charging refrigerant 6 1 About the refrigerant This...

Page 10: ...he GWP value mentioned on the refrigerant charge label 2 Fix the label on the inside of the outdoor unit near the gas and liquid stop valves 7 Electrical installation DANGER RISK OF ELECTROCUTION WARN...

Page 11: ...1 Remove the service cover 2 Open the wire clamp 3 Connect the interconnection cable and power supply as follows f 50 Hz 220 240 V a b c d e a Interconnection cable b Power supply cable c Circuit brea...

Page 12: ...saving connector 3 Turn ON the main power supply 10 Commissioning NOTICE General commissioning checklist Next to the commissioning instructions in this chapter a general commissioning checklist is als...

Page 13: ...r saving 2 Power supply fault 3 Turn the power OFF and back ON and check the LED within approximately 3 minutes If the LED is OFF again the outdoor unit PCB is faulty DANGER RISK OF ELECTROCUTION When...

Page 14: ...M Pulse amplitude modulation PCB Printed circuit board PM Power module PS Switching power supply PTC PTC thermistor Q Insulated gate bipolar transistor IGBT Q C Circuit breaker Q DI KLM Earth leak cir...