Precautions on Installation

• 

Check the strength and level of the installation surface so that the unit does not 
cause any operating vibrations or noise after installation.

•  Fix the unit in place securely using foundation bolts, as in the figure. (Prepare 4 

sets of 5/16 inch (M8) or 3/8 inch (M10) foundation bolts, nuts and washers; all 
separately available.)

• 

It is best to screw in the foundation bolts until their ends are 3/4 inch (20mm) 
from the foundation surface.

3/4” (20mm)

Outdoor Unit Installation Diagram

In sites with poor drainage, 

use block bases for the 

outdoor unit.  

Adjust foot height until the unit 

is level. Otherwise, water 

leakage or pooling of water 

may occur.

Appearance of outdoor units may differ from some models.

O.D. 3/8 inch (9.5mm)

Gas pipe

Liquid pipe

O.D. 1/4 inch (6.4mm)

0.21oz/ft (20g/m)

Max. allowable piping length

49-1/4ft (15m) 39-3/8ft (12m)

65-5/8ft (20m) 49-1/4ft (15m)

Max. allowable piping height
Additional refrigerant required for refrigerant 
pipe exceeding 32.8ft (10m) in length.

   *Be sure to add the proper amount of additional refrigerant.

Failure to do so may result in reduced performance.  

**The suggested shortest pipe length is 10ft (3m), in order to avoid 

noise from the outdoor unit and vibration.
(Mechanical noise and vibration may occur depending on how 
the unit is installed and the environment in which it is used.)

10ft (3m)

O.D. 1/2 inch

 (12.7mm)

O.D. 5/8 inch

 (15.9mm)

RX18

, RXN18

RK18

, RKN18

RXL15

RX24

, RXN24

RK24

, RKN24

RX09/12

RK09/12

RXL09/12

RXN09/12

RKN09/12

65-5/8ft (20m)

98-1/2ft (30m)

Min. allowable piping length

X

(Foot bolt-hole centers)

(From unit’s side)

Z

(Foot bolt-hole 

centers)

Y

**

*

Allow 11-13/16” (300mm) 
of work space below the 
ceiling surface.

Where there is a danger of the unit 

falling, use foot bolts, or wires.

18-1/2 

inch 

(470mm)

23-5/8 

inch 

(600mm)

12-1/8 

inch 

(308mm)

13-5/8 

inch 

(346mm)

3-13/16 

inch 

(97mm)
4-15/16 

inch 

(125mm)

15/18/24 class

09/12 class

X

Y

Z

CAUTION

Keep the piping length between 
10ft (3m) and 65-5/8ft (20m) 
(for RX09/12, RK09/12, RXL09/12), 
10ft (3m) and 49-1/4ft (15m) 
(for RXN09/12, RKN09/12), 
10ft (3m) and 98-1/2ft (30m) 
(for 15/18/24 class).

9-13/16” (250mm) from wall

How to remove the stop 

valve cover

1) Remove the screw on the 

stop valve cover.

2) Slide the stop valve cover 

downward to remove it.

1) Insert the upper part of 

the stop valve cover into  

the outdoor unit.

2) Tighten the screw.

How to attach the stop 

valve cover

Stop valve cover

Wrap the insulation pipe with 

finishing tape from bottom to 

top.

Allow space for piping 

and electrical servicing.

English

01_EN_3P379970-6B.indd   4

11/13/2015   15:48:25

Summary of Contents for RX09NMVJU

Page 1: ...U RXN18NMVJU RXN24NMVJU RK09NMVJU RK12NMVJU RK18NMVJU RK24NMVJU RKN09NMVJU RKN12NMVJU RKN18NMVJU RKN24NMVJU RXL09QMVJU RXL12QMVJU RXL15QMVJU DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split...

Page 2: ...ts and an asphyxiation hazard could occur leading to serious injury or death Do not ground units to water pipes gas pipes telephone wires or lightning rods as incomplete grounding can cause a severe s...

Page 3: ...re should be prevented from getting into the system b Tight R410A does not contain any chlorine does not destroy the ozone layer and does not reduce the earth s protection again harmful ultraviolet ra...

Page 4: ...re more than 10ft 3m away depending on radio wave conditions 8 In coastal areas or other places with a salty atmosphere or one containing sulfate gas corrosion may shorten the life of the air conditio...

Page 5: ...length is 10ft 3m in order to avoid noise from the outdoor unit and vibration Mechanical noise and vibration may occur depending on how the unit is installed and the environment in which it is used 1...

Page 6: ...w Top view More than 5 7 8 150 More than 11 13 16 300 More than 1 15 16 50 Walls facing three sides unit inch mm unit inch mm Top view More than 3 15 16 100 More than 13 3 4 350 More than 1 15 16 50 W...

Page 7: ...in order to guarantee its service life The drying material may dissolve and damage the system Incomplete flaring may result in refrigerant gas leakage 4 Refrigerant piping CAUTION Use the flare nut f...

Page 8: ...e than 550psi 3 8MPa for 1 hour minimum 24 hours recommended If there is a pressure drop check for leaks make repairs and perform the pressure test again 2 Connect the gauge manifold s charging hose t...

Page 9: ...on materials When using commercial copper pipes and fittings observe the following Insulation material Polyethylene foam Heat transfer rate 0 041 to 0 052W mK 0 024 to 0 030Btu fth F 0 035 to 0 045kca...

Page 10: ...Tighten the terminal screws securely It is recommended that a flathead screwdriver be used to tighten the screws The screws are packed with the terminal block 1 2 3 1 2 3 Circuit breaker Ground fault...

Page 11: ...r power supply wiring When using stranded wires make sure to use the round crimp style terminal for connection to the power supply terminal block Stranded wire Round crimp style terminal Arrow view Fl...

Page 12: ...Pump Down Operation In order to protect the environment be sure to pump down when relocating or disposing of the unit 1 Remove the valve cap from the liquid stop valve and gas stop valve 2 Carry out f...

Page 13: ...the instructions in the installation manual for the indoor unit The air conditioner draws a small amount of power in its standby mode If the system is not to be used for some time after installation...

Page 14: ...Two dimensional bar code is a manufacturing code 3P379970 6B M15B135 1511 HT...

Reviews: