Safety Considerations   ....................................  1

Accessories   .....................................................  3

Precautions for Selecting a Location   ...........  3

Precautions on Installation   ............................  4

Outdoor Unit Installation Diagram   ................  4

Installation Space Requirements   ..................  5

Outdoor Unit Installation   ................................  5

1.  Installing the outdoor unit ............................................ 5
2.  Drain work (only for heat pump 

models, excluding RXL models) .................................. 6

3.  Flaring the pipe end ..................................................... 6
4.  Refrigerant piping ........................................................ 6
5.  Pressure test and evacuating system .......................... 7

6.  Refilling refrigerant

 ...................................................... 8

7.  Refrigerant piping work  .............................................. 8

Wiring   ...............................................................  9

Facility Setting 
(cooling at low outdoor temperature)   ...........  11

Pump Down Operation   ...................................  11

Trial Operation and Testing   ...........................  12

1.  Trial operation and testing ........................................... 12
2.  Test items .................................................................... 12

Safety Considerations

Read these 

Safety Considerations for Installation

 carefully 

before installing an air conditioner or heat pump. After completing 

the installation, make sure that the unit operates properly during 

the startup operation.

Instruct the user on how to operate and maintain the unit.

Inform users that they should store this installation manual with 

the operation manual for future reference.

Always use a licensed installer or contractor to install this product.

Improper installation can result in water or refrigerant leakage, 

electric shock, fire, or explosion. 

Meanings of 

DANGER

WARNING

CAUTION

, and 

NOTE

 

Symbols:

 DANGER  ...........

Indicates an imminently hazardous 

situation which, if not avoided, will 

result in death or serious injury.

 WARNING  .........

Indicates a potentially hazardous 

situation which, if not avoided, could 

result in death or serious injury.

 CAUTION  ..........

Indicates a potentially hazardous 

situation which, if not avoided, may 

result in minor or moderate injury. 

It may also be used to alert against 

unsafe practices.

 NOTE  ................

Indicates situations that may result 

in equipment or property-damage 

accidents only.

DANGER 

• 

Refrigerant gas is heavier than air and replaces oxygen. 

A massive leak can lead to oxygen depletion, especially 

in basements, and an asphyxiation hazard could occur 

leading to serious injury or death.

• 

Do not ground units to water pipes, gas pipes, telephone 

wires, or lightning rods as incomplete grounding can cause 

a severe shock hazard resulting in severe injury or death. 

Additionally, grounding to gas pipes could cause a gas leak 

and potential explosion causing severe injury or death.

• 

If refrigerant gas leaks during installation, ventilate the 

area immediately. Refrigerant gas may produce toxic gas 

if it comes into contact with fire. Exposure to this gas could 

cause severe injury or death.

• 

After completing the installation work, check that the 

refrigerant gas does not leak throughout the system.

•  Do not install unit in an area where flammable materials 

are present due to risk of explosions that can cause 

serious injury or death.

• 

Safely dispose all packing and transportation materials 

in accordance with federal/state/local laws or ordinances. 

Packing materials such as nails and other metal or 

wood parts, including plastic packing materials used for 

transportation may cause injuries or death by suffocation.

WARNING 

•  Only qualified personnel must carry out the installation 

work. Installation must be done in accordance with this 

installation manual. Improper installation may result in 

water leakage, electric shock, or fire.

• 

When installing the unit in a small room, take measures 

to keep the refrigerant concentration from exceeding 

allowable safety limits. Excessive refrigerant leaks, in the 

event of an accident in a closed ambient space, can lead 

to oxygen deficiency.

•  Use only specified accessories and parts for installation 

work. Failure to use specified parts may result in water 

leakage, electric shock, fire, or the unit falling.

• 

Install the air conditioner or heat pump on a foundation 

strong enough that it can withstand the weight of the unit. 

A foundation of insufficient strength may result in the unit 

falling and causing injuries.

• 

Take into account strong winds, typhoons, or earthquakes 

when installing. Improper installation may result in the unit 

falling and causing accidents.

01_EN_3P379970-6B.indd   1

11/13/2015   15:48:24

Summary of Contents for RX09NMVJU

Page 1: ...U RXN18NMVJU RXN24NMVJU RK09NMVJU RK12NMVJU RK18NMVJU RK24NMVJU RKN09NMVJU RKN12NMVJU RKN18NMVJU RKN24NMVJU RXL09QMVJU RXL12QMVJU RXL15QMVJU DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split...

Page 2: ...ts and an asphyxiation hazard could occur leading to serious injury or death Do not ground units to water pipes gas pipes telephone wires or lightning rods as incomplete grounding can cause a severe s...

Page 3: ...re should be prevented from getting into the system b Tight R410A does not contain any chlorine does not destroy the ozone layer and does not reduce the earth s protection again harmful ultraviolet ra...

Page 4: ...re more than 10ft 3m away depending on radio wave conditions 8 In coastal areas or other places with a salty atmosphere or one containing sulfate gas corrosion may shorten the life of the air conditio...

Page 5: ...length is 10ft 3m in order to avoid noise from the outdoor unit and vibration Mechanical noise and vibration may occur depending on how the unit is installed and the environment in which it is used 1...

Page 6: ...w Top view More than 5 7 8 150 More than 11 13 16 300 More than 1 15 16 50 Walls facing three sides unit inch mm unit inch mm Top view More than 3 15 16 100 More than 13 3 4 350 More than 1 15 16 50 W...

Page 7: ...in order to guarantee its service life The drying material may dissolve and damage the system Incomplete flaring may result in refrigerant gas leakage 4 Refrigerant piping CAUTION Use the flare nut f...

Page 8: ...e than 550psi 3 8MPa for 1 hour minimum 24 hours recommended If there is a pressure drop check for leaks make repairs and perform the pressure test again 2 Connect the gauge manifold s charging hose t...

Page 9: ...on materials When using commercial copper pipes and fittings observe the following Insulation material Polyethylene foam Heat transfer rate 0 041 to 0 052W mK 0 024 to 0 030Btu fth F 0 035 to 0 045kca...

Page 10: ...Tighten the terminal screws securely It is recommended that a flathead screwdriver be used to tighten the screws The screws are packed with the terminal block 1 2 3 1 2 3 Circuit breaker Ground fault...

Page 11: ...r power supply wiring When using stranded wires make sure to use the round crimp style terminal for connection to the power supply terminal block Stranded wire Round crimp style terminal Arrow view Fl...

Page 12: ...Pump Down Operation In order to protect the environment be sure to pump down when relocating or disposing of the unit 1 Remove the valve cap from the liquid stop valve and gas stop valve 2 Carry out f...

Page 13: ...the instructions in the installation manual for the indoor unit The air conditioner draws a small amount of power in its standby mode If the system is not to be used for some time after installation...

Page 14: ...Two dimensional bar code is a manufacturing code 3P379970 6B M15B135 1511 HT...

Reviews: