9-5 Example of connection

In case of a system of switching between cooling and heating, all systems use 2-tube piping (for suction gas piping and liquid piping). No BS unit 
is required.

Example of connection

(Connection of 8 indoor units Heat pump system)

Single outside 

unit installed

(RWEYQ72, 84)

a

b

k

i

j

c

de

s

c

am

b

r

q

o

m

n

p

Outside unit

Outside unit

Outside unit

Outside unit

REFNET joint (A-G)

REFNET joint (A-G)

REFNET joint (A·B)

REFNET joint (A·B)

REFNET header

REFNET header

REFNET header

REFNET header

BS units 

( B1 - B4 )

When m

ultiple 

outside units 

installed

(RWEYQ144~)

Maxim

um 

allo

w

a

b

le 

length

Betw

een outside 

(

)

and indoor units

Betw

een outside br

anch and outside unit 

(In case of R

WEYQ144 or more)

Betw

een outside and indoor units 

Betw

een indoor and indoor units 

Betw

een outside and outside units 

Actual pipe length

Actual pipe length

Actual pipe length

Diff

erence in height

Diff

erence in height

Diff

erence in height

Equiv

alent length

To

tal e

xtension length

Pipe length betw

een outside (

2) and indoor units 

 390 ft

(Example 1,4) unit  8 :

 a + b + c + d + e + s 

 390 ft

(Example 1,4) unit  8 :

 b + c + d + e + s 

 130 ft

Equiv

alent pipe length betw

een outside (

2) and indoor units 

 459 ft (assume equiv

alent pipe length of REFNET joint to be 1.6 ft, that of REFNET header to be 3.3 ft, BSVQ100(36),160(60) is

 13.1 ft and BSVQ250 is 19.7 ft.)

Piping length from outside br

anch to outside unit    

 33 ft     Equiv

alent length:

 max 43 ft 

Diff

erence in height betw

een outside and indoor units (H1) 

 164 ft     (Max 130 ft if the outside unit is belo

w)

Diff

erence in height betw

een indoor units (H2) 

 49 ft

Diff

erence in height betw

een outside unit (main) and outside unit (sub) (H3) 

 6.5 ft

Pipe length from first refr

iger

ant br

anch kit (either REFNET joint or REFNET header ) to indoor unit 

 130 ft

T

otal piping length from outside unit (

2) to all indoor units   

 980 ft

Allo

w

a

b

le 

height 

length

Allo

w

a

b

le length after the br

anch

(Example 3,6) unit   8 :

 a + o  

 390 ft

(Example 2,5) unit   6 :

 a + b + l  

 390 ft,  8 :

 a + m + n + p 

 390 ft

(Example 3,6) unit   8 :

 o 

 130 ft  

(Example 2,5) unit   6 :

 b + l 

 130 ft,  8 :m + n + p 

≤ 

130 ft

≤ 

33 ft (

Equiv

alent length

 

≤ 

43 ft)

u+s 

≤ 

33 ft (

Equiv

alent length

 

≤ 

43 ft)

u+t 

≤ 

33 ft (

Equiv

alent length

 

≤ 

43 ft)

Refr

iger

ant br

anch kits can only be 

used with R410A.

Ho

w to select REFNET joint:

• 

When using REFNET joints at the first br

anch counted from the outside unit side

.

Choose from the f

ollo

wing tab

le in accordance with the capacity of the outside unit.

(Example 1,2,4,5 :

 REFNET joint  

A

 )

Additional ref

er

iger

ant to be charged R (lbs)

(R should be rounded off in units of 0.1 lbs

.)

NO

TE:

If a negativ

e result is gotten f

or R from the f

o

rm

ula at r

ight, 

no refr

iger

ant needs to be added.

R

W

EYQ72, 84

R

W

EYQ144, 168

R

W

EYQ216, 252

KHRP25M33T

KHRP25M72TU

KHRP25M73TU

KHRP26M33T

KHRP26M72TU

KHRP26M73TU

• 

F

or REFNET joints other than the first br

anch, select the proper br

anch kit model based on the total capacity inde

x.

Ho

w to select REFNET header

Select suitab

le one from the tab

le belo

w according to the total capacity of indoor units to be connected to the

do

wn stream of REFNET header

.

Ho

w to select an outside br

anch kit (Needed when the outside unit type is R

WEYQ144 or more

.)

• 

Select from the tab

le belo

w according to the n

umber of outside units

.

(Example 1,4) In case of REFNET Joint  

C

 

, indoor units of  5 +  6  +  7  +  8

(Example 2,5) In case of REFNET Joint   

B

 

, indoor units of  7  +  8

(Example 2,5) In case of REFNET Header

, indoor units of  1 + 2 + 3 + 4 + 5 + 6

(Example 3,6) In case of REFNET Header

indoor units of  1  +  2  +  3  +  4  +  5  +  6  +  7  +  8

Example of do

wnstream indoor units

Piping betw

een refr

iger

ant br

anch kit and refr

iger

ant br

anch kit/BS unit

Piping betw

een BS unit and refr

iger

ant br

anching kit

S

elect one from the tab

le belo

w according to the total capacity of indoor units to 

be connected to do

wnstream.

F

or the gas piping siz

e in case of 2-tube piping betw

een refr

iger

ant br

anching kit/BS unit 

and refr

iger

ant br

anching kit, select the siz

e of suction gas piping.

The siz

e of connection piping should not e

xceed the refr

iger

ant piping siz

e selected 

under the gener

ic ter

m of the system.

Indoor unit connection piping siz

e

Piping betw

een BS unit (refr

iger

ant br

anch kit) and indoor unit

Match to the siz

e of the connection piping on the indoor unit.

mar

k indicates the BS unit (BSVQ100MV1) por

t and connection pipe are 

diff

erent siz

es

. Use the reducing joints included with the BS unit.

a:

φ 

3/4×30 ft

b:

φ

5/8×10 ft

c:

φ 

3/8×10 ft

d:

φ 

3/8×10 ft

e:

φ 

3/8×10 ft

 f:

φ

3/8×10 ft

g:

φ 

1/4×10 ft

h:

φ 

1/4×20 ft

 i:

φ 

1/2×10 ft

 j:

φ 

1/4×10 ft

k:

φ 

1/4×10 ft

 l:

φ 

1/4×10 ft

m

:

φ 

1/4×10 ft

n:

φ 

1/4×10 ft

o:

φ

1/4×10 ft

p:

φ 

1/4×10 ft

 r:

φ

 3/8× 3 ft

s:

φ

 3/8× 3 ft

 t:

φ

 3/8× 3 ft

u:

φ

 5/8× 1 ft

Diameter of liquid pipe (main pipe por

tion) 

R=

+

Outside unit

capacity type

Refrig

erant branc

h kit name

+

+

+

+

+

(Heat reco

v

e

ry

 system) 

If the outside unit is

R

W

EYQ252 and the

piping lengths are as

at r

ight 

R=  30   0.168 + 11   0.114 + 10   0.074 + 49   0.036 + 100   0.015 + 13  = 23.298

b+u

a

c+d+e+f+r+s+t

g+h+j+k+l+m+n+o+p

i

23.3    (lbs)

Total length (ft) of liquid 

piping siz

e at 

φ

7/8

×0.235

(lbs/ft)

  

  

Total length (ft) of liquid 

piping siz

e at

 

φ

3/8

  

  

Total length (ft) of liquid 

piping siz

e at

 

φ

1/4

  

  

Total length (ft) of liquid 

piping siz

e at 

φ

3/4

  

  

Total length (ft) of liquid 

piping siz

e at

 

φ

5/8

  

  

Total length (ft) of liquid 

piping siz

e at

 

φ

1/2

  

  

×0.168

(lbs/ft)

×0.114

(lbs/ft)

×0.074

(lbs/ft)

×0.036

(lbs/ft)

×0.015

(lbs/ft)

System name

1 unit (72 / 84)

2 unit m

ulti (144 / 168)

3 unit m

ulti (216 / 252)

4.4

5.5

6.6

6.6

9.9

13

Heat reco

v

e

ry

 system

Heat pump system

Example f

or refr

iger

ant br

anch using REFNET joint and REFNET header f

or R

WEYQ252

Refrig

erant branc

h kit selection

Pipe siz

e selection

F

or an outside unit m

ulti installation (R

WEYQ144, 168, 216, 252 type),

mak

e the settings in accordance with the f

ollo

wing figure

.

Piping betw

een outside unit and refr

iger

ant br

anch kit (par

t A)

Piping betw

een outside br

anches (par

t B)

Piping betw

een outside br

anch and outside unit (par

t C)

Ho

w to calculate the ad

ditional refrig

erant 

to be c

har

g

e

d

Outside unit

r

s

u

Heat reco

ver

y system

Heat pump system

Indoor unit

capacity type

Piping siz

e (outer diameter)

Liquid pipe

Gas pipe

φ

 1/2

φ

 5/8

φ

 1/4

φ

 3/8

07,09,12,18 type

24,30,36,48 type

(Unit:

 inch) 

Indoor unit connection piping siz

e

Indoor units 

(  1  -   8  )

Heat reco

ve

ry

 system 

(  1  -  6  )

Cooling only 

(  7  

·   8  )

BS units 

( B1 - B4 )

Indoor units 

(  1  -   8  )

Heat reco

ve

ry

system (  1  -  6  )

Cooling only 

(  7  

·   8  )

BS units ( B1 - B5 )

BS units 

( B1 - B5 )

Indoor units 

(  1  -   8  )

Heat reco

ver

y system 

(  1  -  4  ,  7  ·  8  )

Indoor units 

(  1  -   8  )

Cooling only 

(  5  

·   6  )

l

f

g

a

b

c

d

e

h

H2

H1

H1

1

12

3

4

5

6

7

8

23

4

5

6

7

1

1

2

3

456

7

8

23456

7

8

8

B2

B3

B4

B1

B1

B2

B3

B4

B5

B2

B3

B4

B5

d

e

f

g

h

i

j

k

l

m

a

a

b

a

b

d

f

c

e

g

f

h

j

d

c

e

gi

k

l

m

n

o

b

Outside unit

Outside

unit

1

12

3

45

6

7

8

2

34

5

6

7

8

B1

B2

B3

B4

B5

B6

B6

B5

B4

B3

B2

B1

BS units 

( B1 - B6 )

BS units 

( B1 - B6 )

Indoor units 

(  1  -   8  )

Heat reco

ver

y system 

(  1  -  6  )

Heat reco

ve

ry

system (  1  -  6  )

Indoor units 

(  1  -   8  )

Cooling only 

(  7  

·   8  )

Cooling only 

(  7  

·   8  )

First outside 

br

anch

s

r

p

q

n

o

k

i

l

j

h

g

f

H3

H1

H2

h

i

j

k

l

m

n

o

BS

unit

Outside

unit side

(Thic

k line):

 3-tube piping

Indoor

unit side

(3-tube piping)

(2-tube piping)

Discharge gas piping

Gas piping

Liquid piping

Liquid piping

Suction gas piping

• Piping betw

een outside unit and BS unit

Discharge gas piping

Suction gas piping

Liquid piping

(Thin line):

 2-tube piping 

• Piping betw

een BS unit and indoor unit,

Suction gas piping

Liquid piping

If the system capacity is R

WEYQ144 or more

,

re-read the [outside unit] as [the first outside br

anch

seen from the indoor unit side].

[

]

Corrected 

volume b

outside unit

t

H1

H2

Heat reco

ve

ry

 system 

(  1  -  4  ,  7  ·  8  )

Cooling only 

(  5  

·   6  )

m

Branch with REFNET joint

Branch with REFNET joint and REFNET header

Branch with REFNET header

Capacity type

of outside unit

Piping siz

e (outer diameter)

When increased

Standar

d siz

e

φ

 3/8

φ

 1/2

φ

 5/8

φ

 3/4

φ

 1/2

φ

 5/8

φ

 3/4

φ

 7/8

R

W

EYQ72,84

R

W

EYQ144

R

W

EYQ168,216

R

W

EYQ252

Piping betw

een outside unit and refr

iger

ant br

anch kit (par

t A)

Match

 to the siz

e of connection piping of outside unit

Capacity type

of outside unit

Piping siz

e (outer diameter)

Suction gas pipe

φ

 3/4

φ

 7/8

φ

 1-1/8

φ

 1-3/8

Disc

har

g

e gas pipe

φ

 5/8

φ

 3/4

φ

 7/8

φ

 1-1/8

Liquid pipe

φ

 3/8

φ

 1/2

φ

 5/8

φ

 3/4

R

W

EYQ72

R

W

EYQ84

R

W

EYQ144

R

W

EYQ168

R

W

EYQ216

R

W

EYQ252

(Unit:

 inch) 

Example 1

Example 4

Example 2

Example 5

Example 3

Example 6

<72

72

x<111

111

x<246

246

KHRP25M33H

  

KHRP25M72H

KHRP25M73HU

KHRP26M22H, KHRP26M33H

KHRP26M33H

KHRP26M72H

KHRP26M73HU

Indoor

capacity inde

x

Refrig

erant branc

h kit name

In case of 3-tube piping

In case of 2-tube piping

2 unit

3 unit

BHFP26MA56U

BHFP26MA84U

BHFP22MA56U

BHFP22MA84U

Number of units

of outside unit

Heat reco

ver

y system

Heat pump system

<72

72

x<111

111

x<246

246

KHRP25M22T

KHRP25M33T

KHRP25M72TU

KHRP25M73TU

KHRP26M22T

KHRP26M33T

KHRP26M72TU

KHRP26M73TU

Indoor

capacity inde

x

Refrig

erant branc

h kit name

In case of 3-tube piping

In case of 2-tube piping

Piping betw

een outside br

anches (par

t B)

Select the siz

e from the f

ollo

wing tab

le based on the total capacity

of the outside unit to be connected to upstream 

Capacity type

of outside unit

Piping siz

e (outer diameter)

Suction gas pipe

φ

 1-1/8

Disc

har

g

e gas pipe

φ

 7/8

Liquid pipe

φ

 1/2

φ

 5/8

R

W

EYQ144

R

W

EYQ168

(Unit:

 inch) 

Piping betw

een outside br

anch and outside unit (par

t C)

Capacity type

of outside unit

Piping siz

e (outer diameter)

Suction gas pipe

φ

 3/4

φ

 7/8

Disc

har

g

e gas pipe

φ

 5/8

φ

 3/4

Liquid pipe

φ

 3/8

R

W

EYQ72

R

W

EYQ84

(Unit:

 inch) 

Piping siz

e increase in case of long piping

When the equiv

alent length is 262.5 ft or more

, it is necessar

y to 

increase the siz

e of the main pipe of liquid piping side

.

When the equiv

alent length is 262.5 ft or more

, do not increase the siz

es 

of discharge and suction gas pipes

.

(Unit:

 inch) 

(Unit:

 lbs)

Indoor unit

capacity type

Piping siz

e (outer diameter)

Suction gas pipe

φ

 1/2

φ

 5/8

φ

 7/8

φ

 1-1/8

φ

 1-1/4

Disc

har

g

e gas pipe

φ

 3/8

φ

 1/2

φ

 3/4

φ

 1-1/8

Liquid pipe

φ

 1/4

φ

 3/8

φ

 1/2

φ

 5/8

φ

 3/4

<24

24

x<72

72

x<111

111

x<162

162

x<246

246

(Unit:

 inch) 

B1

B1

B2

B3

B4

n

p

o

H2

c

d

e

f

g

h

i

j

k

l

n

p

o

u

t

s

r

H3

H2

H1

H3

H1

H2

A

B

A

AB

CDE

B

F

AB

C

D

E

G

FG

Summary of Contents for RWEYQ144PTJU

Page 1: ...for future reference This manual should be left with the equipment owner Lire soigneusement ces instructions avant I installation Concerver ce manuel port e de main pour r f rence ult rieure Ce manuel...

Page 2: ...6 13 16 3 15 16 9 13 16 21 5 8 30 11 16 9 9 8 10 8 9 7 7 6 6 6 9 7 8 5 8 15 3 8 4 3 1 2 11 13 16 39 3 8 35 7 16 19 11 16 1 2 3 4 4 10 5 6 5 4 9 6 7 7 10 8 1 2 3 4 9 Heat recovery system Heat pump syst...

Page 3: ...figure 13 figure 12 figure 11 A B C A B C F1 F1 F2 F2 Q1 Q2 F1 F2 F1 F2 F1 F2 F1 F2 F1 F2 F1 F2 F1 F2 F1 F2 F1 F2 4 5 6 1 2 7 C H SELECTOR TO IN D UNIT TO OUT D UNIT TO MULTI UNIT 3 A B C F1 F1 F2 F2...

Page 4: ...very system 1 2 3 4 5 6 7 8 9 10 11 5 4 12 14 15 16 17 13 figure 16 A B C A B C 1 DS1 1 2 3 4 OFF ON O U T I N TO IN D UNIT F1 F2 A1P A1P DS1 1 2 3 4 OFF ON O U T I N F1 F2 P1 P2 P1 P2 1 1 2 6 3 3 4 5...

Page 5: ...4 5 6 Heat pump system Heat recovery system 4 5 3 2 1 figure 24 1 11 1 2 2 4 3 4 3 5 5 R410A R410A 9 7 7 8 13 9 6 6 16 10 10 10 10 17 12 12 14 15 15 18 18 Heat pump system Heat recovery system 1 2 3...

Page 6: ...sult in equipment or property damage accidents only DANGER Refrigerant gas is heavier than air and replaces oxygen A massive leak can lead to oxygen depletion especially in base ments and an asphyxiat...

Page 7: ...on tribute to the greenhouse effect if it is released Therefore take proper measures to check for the tightness of the refrig erant piping installation Read the chapter Refrigerant Pip ing and follow...

Page 8: ...itches off automatically in order to protect the unit from freezing Hold ambient temperature at 35 95 F Heat release from the unit 0 64 kW hour Model 72 84 It is therefore recommended to always ventil...

Page 9: ...emale Thread 1 2FPS 2 female Thread General RWEYQ216PTJU RWEYQ252PTJU Nominal cooling capacity 2 MBh 216 252 Nominal cooling capacity 3 MBh 243 283 5 Nominal input cooling heating 4 kW 12 60 12 00 16...

Page 10: ...ower without fail Open type tower cannot be used 4 Strainer Install the strainer accessory without fail at the inlet of water pip ing If sands wastes rust particles etc are mixed in the water cir cula...

Page 11: ...manner 7 1 When designing the equipment 1 Install the strainer accessory at the water inlet side adjacent to the outside unit in order to prevent any foreign materials such as dust sand etc from ente...

Page 12: ...within the standard 2 Clean the strainer 3 Make sure that the flow rate is correct 4 Make sure that the operational conditions pressure flow rate outlet temperature etc are normal 2 Because the plate...

Page 13: ...fect but also may cause the capacitor to overheat due to high frequency waves Therefore never install a phase advancing capacitor Keep power imbalance within 2 of the supply rating 1 Large imbalance w...

Page 14: ...electromagnetic switch for the water pump to each outside unit Select without fail an auxiliary a contact able to switch min imum load of DC15V 1mA When connecting for each outside unit Connect to the...

Page 15: ...erminals for connections to the power terminal block When none is available follow the instructions below Do not connect wiring of different thicknesses to the power termi nal block Slack in the power...

Page 16: ...s always required When installing the piping follow the instructions in the installation manual that comes with the kit Restriction for the installation of the outside unit multi connection piping kit...

Page 17: ...cal piping with the provided insulation to prevent it from coming into contact with the casing Precautions for installation of units NOTE The outside unit multi connection piping kit that is sold sepa...

Page 18: ...c d e f r s t g h j k l m n o p i 23 3 lbs Total length ft of liquid piping size at 7 8 0 235 lbs ft Total length ft of liquid piping size at 3 8 Total length ft of liquid piping size at 1 4 Total len...

Page 19: ...etc this must be prevented by caulking the connections etc WARNING Be sure to insulate connection piping as touching them can cause burns 9 8 Checking of device and installation conditions Be sure to...

Page 20: ...refrigerant 9 10 Stop valve operation procedure CAUTION Do not open the stop valve until 1 6 of 9 8 Checking of device and installation conditions are completed If the stop valve is left open without...

Page 21: ...onfiguration on the main unit Any settings made on a sub unit will be ignored After this close the electrical compo nents box lid Always perform configuration after turning ON the power To learn the s...

Page 22: ...rding to local regulations or standards The following standards may be applicable if local regulations are not available The VRV System like other air conditioning systems uses R410A as refrigerant R4...

Page 23: ...e open ings above and below the door which are each equivalent in size to 0 15 or more of the floor area 3 Calculating the refrigerant density using the results of the calcula tions in steps 1 and 2 a...

Page 24: ...1645 Wallace Drive Suite 110 Carrollton TX 75006 info daikinac com www daikinac com 3P153897 12P EM09A022 0910 FS...

Reviews: