6-4 PROGRAMMING START AND STOP OF
THE SYSTEM WITH TIMER
(Refer to figure 7)
• The timer is operated in the following two ways.
Programming the stop time “
”
The system stops operating after the set
time has elapsed.
Programming the start time “
”
The system starts operating after the set
time has elapsed.
• The timer can be programmed for a maxi-
mum of 72 hours.
• The start and the stop time can be simulta-
neously programmed.
Press the timer mode start/stop button several
times and select the mode on the display.
The display flashes.
• For setting the timer stop “
”
• For setting the timer start “
”
Press the programming time button and set
the time for stopping or starting the system.
Each time this button is pressed, the
time advances or goes backward by
1 hour.
Press the timer on/off button.
The timer setting procedure ends. The display
“
” or “
” changes from flashing
light to constant light.
NOTE
• When setting the timer off and on at the
same time, repeat the above procedure
(from “
” to “
”) once again.
• After the timer is programmed, the display
shows the remaining time.
• Press the timer on/off button once again to
cancel programming. The display vanishes.
For example: (Refer to figure 8)
When the timer is programmed to stop the sys-
tem after 3 hours and start the system after 4
hours, the system will stop after 3 hours and
start 1 hour later.
6-5 SETTING THE MASTER REMOTE CON-
TROLLER
• In the case of the system as shown in figure 9,
only the master remote controller can select oper-
ation mode.
(Refer to figure 9)
1. Outdoor unit
2. Indoor unit
3. Remote controller
4. One of these remote controller is master
remote controller.
• Only the master remote controller can select
heating, cooling operation.
• The displays of slave remote controllers show
“
” (changeover under control) and they
automatically follow the operation mode directed
by the master remote controller.
However, it is possible to changeover to program
dry with slave remote controllers if the system is in
cooling operation by setting on the master remote
controller and to changeover to fan only opera-
tion.
How to designate the master remote controller
(Refer to figure 10)
Press the operation mode selector button of
the current master remote controller for 4 sec-
onds.
The display showing “
” (changeover
under control) of all remote controllers con-
nected to the same outdoor unit flashes.
Press the operation mode selector button of
the controller that you wish to designate as the
master remote controller. Then designation is
completed. This remote controller is desig-
nated as the master remote controller and the
display showing “
” (changeover
under control) vanishes.
The displays of other remote controllers show
“
” (changeover under control).
How to change the operation mode
(Refer to figure 10)
Press the operation mode selection button of
the master remote controller, which does not
show “
” (changeover under control)
repeatedly until the air conditioner is set to the
desired operation mode.
The display will change to “
”, “
”, “
”,
or “
” each time the button is pressed.
The other remote controllers with no option
rights will follow suit and change their displays
automatically.
6-6 PRECAUTIONS FOR GROUP CON-
TROL SYSTEM OR TWO REMOTE CON-
TROLLER CONTROL SYSTEM
This system provides two other control systems
beside individual control (one remote controller con-
trols one indoor unit) system. Confirm about your sys-
tem to Daikin dealer.
•
Group control system
One remote controller controls up to 16 indoor
units. All indoor units are equally set.
1
2
3
1
3
1
2
3