52
10.3
Electrical diagram
A
Earth connection exchanger
F
Fuse (3.15 A T)
P1
CH pump
S7
CH water pressure sensor
B
Ignition hood
G
Gas block + ignition module
R
Resistance
V
Fan
C
Boiler controller
I
Ignition/ionization pin
S1
Leaving water sensor
E
Earth connections
M
Mains electricity supply
S2
Return sensor
Connector X4
24V=
5 -
PWM control CH-pump. (5= PWM signal (red), E=earth)
6-7
On/off room thermostat
(0.1A-24Vdc)
and/or frost thermostat
8-9
Outdoor sensor
(12 kOhm / 25°C)
9-10
Tank sensor
(12 kOhm / 25°C)
11-12
OpenTherm room thermostat
(6-7 should be open)
Connector X2
230V
~
2-4
Mains supply 230 V (2 = L (brown), 4 = N (blue))
7-8
CH pump
(8 = L (brown), 7 = N (blue))
3-5-6
Three-way valve for external tank
(3 = L (brown), 5 = Switch (black), 6 = N (blue))
(e.g. EK3WV1AA)
Connector X5
Computer interface