Si001353EB
Compressor
Removal Procedure
19
2
Disconnect the lead
wires of the compressor
and the overload
protector.
3
Remove the 2 or 3 nuts
(depending on the
model) of the
compressor.
4
Heat up the brazed part
of the discharge side
pipe and disconnect.
5
Heat up the brazed part
of the suction side pipe
and disconnect.
Some models have a sheet
of putty, make sure to
remove it beforehand.
Step
Procedure
Points
V
W
U
(R20182)
Red (U)
Yellow (V)
Blue (W)
Overload
protector
(R10887)
Compressor
(R12031)
Brazed part of discharge side pipe
(R12032)
Blazed part of
suction side pipe