![background image](http://html1.mh-extra.com/html/daikin/rks09jv2s/rks09jv2s_removal-procedure_2459847012.webp)
PCBs
Si001353EB
10
Removal Procedure
5
Disconnect the
connector [HN3].
[HN3]: filter PCB
6
Remove the 6 screws.
7
8
Unfasten the 2 hooks
on the lower side.
Lift and pull out the
main PCB.
The electrical box also has 2
hooks on the upper side.
When reassembling, be sure
to fit all the 4 hooks.
2. Remove the filter PCB.
1
Remove the 2 screws
and release the earth /
ground wires.
Step
Procedure
Points
(R12599)
[HN3]
(R12600)
(R22536)
Hook
Hook
Earth / ground wire
(R22533)