![background image](http://html1.mh-extra.com/html/daikin/rks09jv2s/rks09jv2s_removal-procedure_2459847016.webp)
Thermistor ASSY
Si001353EB
14
Removal Procedure
6. Thermistor ASSY
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Release the discharge
pipe thermistor.
Be careful not to lose the
fixture for the thermistor.
2
Pull out the outdoor
heat exchanger
thermistor.
Be careful not to lose the clip
for the thermistor.
3
Cut the clamp and
remove the thermistor
ASSY.
Discharge pipe thermistor
(R12619)
Fixture
(R22337)
Outdoor heat exchanger thermistor
(R12620)
Clip
(R3264)
(R12621)
Thermistor
ASSY