![background image](http://html1.mh-extra.com/html/daikin/rkm46pvma/rkm46pvma_service-manual_2459839008.webp)
Electrical Box
Si001421EA
6
Removal Procedure
3. Electrical Box
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1. Remove the right side
panel.
When reassembling, make
sure to fit the 6 hooks.
1
2
Remove the screw.
Pull down and remove
the stop valve cover.
3
4
Remove the 2 screws.
Slide upward and
remove the shield plate.
5
Remove the 3 screws
and remove the wire
fixture.
Stop valve cover
(R21383)
(R21384)
Shield plate
(R21385)
Wire fixture
(R21386)