![background image](http://html1.mh-extra.com/html/daikin/rkm46pvma/rkm46pvma_service-manual_2459839006.webp)
Outdoor Fan / Fan Motor
Si001421EA
4
Removal Procedure
2. Outdoor Fan / Fan Motor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Remove the drip proof
cover.
2
Cut the clamp.
3
4
Disconnect the
connector [S70].
Release the fan motor
lead wire from the
groove and the hook.
[S70]: fan motor
Drip proof cover
(R21376)
Clamp
(R21377)
Hook
[S70]
Groove
Fan motor
lead wire