![background image](http://html1.mh-extra.com/html/daikin/rkm46pvma/rkm46pvma_service-manual_2459839015.webp)
Si001421EA
PCBs
Removal Procedure
13
8
9
10
Disconnect the
connector [S206].
Remove the screw.
Unfasten the hook and
remove the demand
control PCB.
The demand controller as an
optional accessory has
[S204] and [S205] instead of
[S206].
[S206] / [S204][S205]: smart
meter
Some models have no
demand control PCB.
11
12
Remove the 7 screws.
Unfasten the 5 hooks
and remove the main
PCB.
Step
Procedure
Points
Hook
[S206]
(R21413)
Demand
control PCB
(R21414)
Hook
(R21415)
Main PCB
(R21416)