![background image](http://html1.mh-extra.com/html/daikin/rkm46pvma/rkm46pvma_service-manual_2459839013.webp)
Si001421EA
PCBs
Removal Procedure
11
4. PCBs
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Remove the 2 screws
and detach the earth /
ground wires.
2
Cut the clamp.
The position of the clamp
varies depending on the
models.
3
Pull out the 3 clamps.
Some models have only 2
clamps.
Earth / ground
screw
Earth / ground screw
(R21406)
Clamp
(R21407)
Clamp
Clamp
(R21408)