![background image](http://html1.mh-extra.com/html/daikin/rkm25prv16/rkm25prv16_service-manual-removal-procedure_2459837012.webp)
PCB
Si001410EB
10
Removal Procedure
5. PCB
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Remove the screw on
the terminal board.
You can remove the PCB
when you disconnect the
lead wires on the terminal
board without removing the
terminal board.
2
3
Remove the earth/
ground screw (lower).
Disconnect all the
terminals from the
terminal board.
4
Cut the clamp.
Terminal board
(R23501)
(R23503)
Earth/ground
screw (lower)
(R23502)
White
Red
Black
Green
(earth/ground)
Clamp
(R20283)