![background image](http://html1.mh-extra.com/html/daikin/rkm25prv16/rkm25prv16_service-manual-removal-procedure_2459837019.webp)
Si001410EB
Compressor
Removal Procedure
17
2
3
Disconnect the lead
wires of the compressor
and the overload
protector.
Remove the protection
bushing.
4
5
6
7
Remove the putties, if
any.
Heat up the 2 brazed
parts and disconnect
the pipings.
Remove the 3 nuts of
the compressor.
Lift up the compressor
and remove it.
Step
Procedure
Points
Protection bushing
Overload
protector
V (yellow)
W (blue)
U (red)
(R22677)
Nut
(R22592)