Reactor / Partition Plate
Si001410EB
12
Removal Procedure
6. Reactor / Partition Plate
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
2
Remove the screw.
Slide the reactor to the
left and remove the
reactor.
3
Remove the 2 screws.
4
Lift and remove the
partition plate.
When reassembling, fit the 2
lower hooks into the bottom
frame.
Reactor
(R22676)
(R20650)
Partition plate
Hook
(R23505)