![background image](http://html1.mh-extra.com/html/daikin/rkh50qrv16/rkh50qrv16_removal-procedure_2459833007.webp)
Si001409EB
Outdoor Fan / Fan Motor
Removal Procedure
5
2. Outdoor Fan / Fan Motor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
2
Disconnect the
connector [S70].
Release the fan motor
lead wire from the
groove of the partition
plate and from the 4
hooks on the electrical
box.
This procedure is not
necessary to remove only
the outdoor fan.
[S70]: fan motor
3
Remove the nut, and
then the outdoor fan.
Nut size: M6
When reassembling, align
the
mark of the outdoor
fan with the D-cut section of
the motor shaft.
(R20739)
[S70]
Groove
Hook
(R19360)
Outdoor fan
(R18431)
10 mm
(0.39 inch)
(R18954)