![background image](http://html1.mh-extra.com/html/daikin/rkh50qrv16/rkh50qrv16_removal-procedure_2459833008.webp)
Outdoor Fan / Fan Motor
Si001409EB
6
Removal Procedure
4
5
Remove the screw of
the fan motor fixing
frame.
Unfasten the 2 hooks at
the bottom and remove
the fan motor fixing
frame.
When reassembling, fit the 2
lower hooks into the bottom
frame.
6
Open the 2 hooks and
release the fan motor
lead wire.
When reassembling, put the
fan motor lead wire through
the back of the fan motor to
avoid entanglement with the
outdoor fan.
7
Remove the 4 screws,
and then the fan motor.
Step
Procedure
Points
(R18432)
Fan motor fixing frame
(R22574)
(R18433)
Hook
Fan motor lead wire
(R3249)
Lead wire
Outdoor fan
(R18434)
Fan motor