Compressor
Si001409EB
20
Removal Procedure
2
3
Remove the protection
bushing.
Disconnect the
compressor lead wires
and the overload
protector.
4
5
6
Remove the putties.
Heat up the brazed part
of the discharge side
pipe and disconnect it.
Heat up the brazed part
of the suction side pipe
and disconnect it.
7
8
Remove the 3 nuts of
the compressor.
Lift the compressor up
and remove it.
Step
Procedure
Points
(R22576)
U (red)
W (blue)
V (yellow)
Protection
bushing
Overload
protector
Putty
Brazed part of the
suction side pipe
Brazed part of the
discharge side pipe
Putty
(R23816)
(R20630)