![background image](http://html1.mh-extra.com/html/daikin/rk15kevm/rk15kevm_removal-procedure_2459827024.webp)
Removal of Compressor
Si001159
22
Removal Procedure
6. Removal of Compressor
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove the peripheries.
1
Remove the terminal
cover.
2
Remove the protection
bushing.
3
Disconnect the
terminals of the
compressor.
4
Remove the overload
protector.
5
Remove the 3 fixtures
of the compressor with
a flat screwdriver.
(R14826)
Terminal cover
(R14827)
Protection bushing
U
V
W
(R14828)
U (red)
V (yellow)
W (blue)
Overload
protector
(R15011)
Compressor
Fixtures