Removal of Electrical Box / PCBs
Si001159
12
Removal Procedure
2
Disconnect the relay
connector for the
compressor motor.
3
Release the harnesses
from the hook.
4
Disconnect the
connector for the
electronic expansion
valve coil [S20].
5
Unfasten the hook of
the electrical box from
the partition plate with a
flat screwdriver.
The electrical box can be
removed without a
screwdriver.
Step
Procedure
Points
(R11774)
(R14800)
(R14801)
[S20]
(R7318)