background image

17

18

5-room centralised

controller

KRC72

Remote controller loss 

prevention with chain

KKF917A4

Options  

Specifications  

Titanium apatite photocatalytic 

air-purifying filter

KAF970A48

Measurement conditions

1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.

2. Sound pressure levels are measured in an anechoic chamber based on temperature condition 1 above. These values are normally 

somewhat higher during actual 

operation as a result of ambient conditions.

Note: The above values are based on operation with a 220V, 60Hz power suuply.

Outdoor unit

Control system

No.

1
2

Item 

Air direction adjustment grille
Drain plug

Note: *1. One set includes 5 pieces for 5 units.

Central remote controller

DCS302CA61

Unified On/Off controller

DCS301BA61

Schedule timer

DST301BA61

Air direction adjustment grille

KPW945A4

Drain plug

KKP945A4

Drain plug

KKP937A4

No.

1
2
3
4

Item 

Central remote controller
Unified On/Off controller
Schedule timer
Interface adaptor for DIII-NET use

Note: *1. Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit. 

*

1

*

1

*

1

*

1

Titanium apatite photocatalytic 

air-purifying filter

KAF970A46

DCS302CA61
DCS301BA61

DST301BA61

KRP928BB2S

FTKS25/35G, FTKS50/60/71/85H   

RKS50/60H

RKS71H

RKS85H

KPW5E112

RKS25/35EB

KPW937A4

Indoor unit

Notes: *1. The 3m (BRCW901A03) - or 8m (BRCW901A08) - length wired remote controller cord is required.

            *2. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.

            *3. The time clock and other devices should be obtained locally. 

            *4. The filter is a standard accessory. It should be replaced approximately every 3 years.  

No.

1

2

3

4

5
6

FTKS71/85H 

KAF970A48

FTKS50/60H

KRC72

KRP413AB1S

KKF917A4

FTKS25/35G

BRC944B2

BRCW901A03
BRCW901A08

*

1

*

2

*

3

*

4

Specifications are subject to change.

Item 

Wired remote controller 

Wired remote controller cord

5-room centralised controller
Wiring adaptor for time clock/remote controller 

(Normal open pulse contact/normal open contact)
Titanium apatite photocatalytic air-purifying filter
Remote controller loss prevention with chain

KPW945A4



KAF970A46

Length 3 m  (shielded wire)
Length 8 m  (shielded wire)

 

4

A

5

4

9

P

K

K

4

A

7

3

9

P

K

K

FTKS71/85H

Indoor unit

Outdoor unit

Model name

Capacity
Power supply

Running current

Power consumption

COP 

Indoor unit

Front panel colour

Airflow rate (H)

Fan speed

Sound pressure level (H/L/SL)

Dimensions (H x W x D)

Machine weight 

Outdoor unit

Casing colour
Compressor
Refrigerant charge (R-410A)

Sound pressure level (H/SL)

Dimensions (H x W x D)

Machine weight

Operation range

Piping 

connection

Max. piping length

Max. height difference

Rated (Min.-Max.)

Rated

Rated

Rated

Motor output

FTKS71HVM

RKS71HVM

7.1 (2.7-8.7)

24,200 (9,200-29,700)

9.6

2,060

3.45

FTKS71HVM

21.7 (766)

46/37/34

RKS71HVM

1,920

2.0

52/49

770 x 900 x 320

60

  

15

FTKS85HVM

RKS85HVM

8.5 (3.0-9.7)

29,000 (10,200-33,100)

11.6

2,540

3.35 

FTKS85HVM

23.0 (812)

49/40/37

RKS85HVM

2,030

2.7

55/52

990 x 940 x 320

73

20

O.D.   16.0

30

Liquid

Gas

Drain

 

White

5 steps, quiet and automatic

340 x 1,200 x 240

17

Ivory white

Hermetically sealed swing type

19.4 to 46

   9.5 

15.9

kW

Btu/h

A

W

W/W

m

3

/min (cfm)

dB (A)

mm

kg

W

kg

dB (A)

mm

kg

 CDB

mm

m

1 phase, 220-240 V / 220-230 V, 50/60 Hz   

Type

Summary of Contents for PCRPH1308

Page 1: ... re or explosion Use only those parts and accessories supplied or speci ed by Daikin Ask a quali ed installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage electrical shock re or explosion Read the User s Manual carefully before using this product The User s...

Page 2: ...ty for each room size The 5 0 to 8 5 kW models also feature a new design The DC Inverter air conditioners achieve high COPs of 3 31 or more thanks to their swing compressor with Reluctance DC motor COP FTKS25G RKS25EB 4 10 FTKS35G RKS35EB 3 31 FTKS50H RKS50H 3 85 FTKS60H RKS60H 3 68 COP COP FTKS71H RKS71H 3 45 FTKS85H RKS85H 3 35 What is COP An air conditioner s COP Coefficient of Performance indi...

Page 3: ...apacity kW Btu h 5 2 1 7 6 2 17 700 5 800 21 200 FTKS60HVM RKS60HVM Model Cooling Capacity kW Btu h 6 0 2 3 6 9 20 500 7 800 23 500 FTKS71HVM RKS71HVM Model Cooling Capacity kW Btu h 7 1 2 7 8 7 24 200 9 200 29 700 FTKS85HVM RKS85HVM Model Cooling Capacity kW Btu h 8 5 3 0 9 7 29 000 10 200 33 100 Product Lineup Note indicates a new capacity model indicates a new design model 2 46 1 2 3 0 8 400 4 ...

Page 4: ... Reluctance DC motor Swing compressor Thanks to its smooth rotation the swing compressor decreases friction and vibration It also prevents the leakage of refrigerant gas during compression These advantages provide quiet and efficient compression PAM Pulse Amplitude Modulation control reduces energy loss by controlling how often the converter switches on and off Inverters are devices that are able ...

Page 5: ... this function Intelligent Eye Outdoor Unit Quiet Operation 3 dB A RKS25EB Operations Rated H Quiet SL Sound pressure levels 46 dB A 43 dB A 3 dB A Selects fan speed and Indoor Unit Quiet Operation Indoor Unit Quiet Operation icon Outdoor Unit Quiet Operation The Intelligent Eye indicator lights when movement is detected Intelligent Eye sensor Intelligent Eye button Econo Mode button When you are ...

Page 6: ...s From a corner to the centre Covers even a spacious room Vertical Auto Swing up and down Horizontal Auto Swing left and right 3 D Airflow Comfort Airflow Mode prevents uncomfortable drafts from blowing directly on to your body With this function when you press the COMFORT button the flap moves upward to prevent direct cold drafts This function is available for 5 0 to 8 5 kW models Comfort Airflow...

Page 7: ...eria are only effective for substances that are collected on and in direct contact with the Titanium Apatite Photocatalytic Air Purifying Filter Apatite adsorbs bacteria At the same time the photocatalyst oxidises odour components breaking them down Effect of Titanium Apatite Photocatalyst Titanium Apatite Photocatalyst Odours Bacteria Decomposed Decomposed Light Adsorbs Removes Cleanliness and Du...

Page 8: ...the wireless remote controller The On timer and Off timer can be used in combination Pressing the Off timer button automatically selects Night Set Mode This function prevents excessive cooling for a pleasant sleep Room temperature is raised by 0 5 C after 60 minutes The air conditioner memorises the settings for mode airflow temperature etc and automatically returns to them when power is restored ...

Page 9: ...sions H x W x D Machine weight Outdoor unit Casing colour Compressor Refrigerant charge R 410A Sound pressure level H SL Dimensions H x W x D Machine weight Operation range Piping connection Max piping length Max height difference Rated Min Max Rated Rated Rated Motor output FTKS25GVMA RKS25EBVMA 2 46 1 2 3 0 8 400 4 100 10 200 3 5 600 4 10 FTKS25GVMA 8 7 307 37 25 22 RKS25EBVMA 46 43 FTKS35GVMA R...

Page 10: ...nd other devices should be obtained locally 4 The filter is a standard accessory It should be replaced approximately every 3 years No 1 2 3 4 5 6 FTKS71 85H KAF970A48 FTKS50 60H KRC72 KRP413AB1S KKF917A4 FTKS25 35G BRC944B2 BRCW901A03 BRCW901A08 1 2 3 4 Specifications are subject to change Item Wired remote controller Wired remote controller cord 5 room centralised controller Wiring adaptor for ti...

Reviews: