FTKS25/35G

RKS50/60H

FTKS50/60H

RKS25/35EB

FTKS71/85H

RKS71H

RKS85H

FTKS25GVMA / RKS25EBVMA

Model

Cooling
Capacity

kW

Btu/h

FTKS35GVMA / RKS35EBVMA

Model

Cooling
Capacity

kW

Btu/h

FTKS50HVM / RKS50HVM

Model

Cooling
Capacity

kW

Btu/h

5.2 (1.7-6.2)
17,700 (5,800-21,200)

FTKS60HVM / RKS60HVM

Model

Cooling
Capacity

kW

Btu/h

6.0 (2.3-6.9)
20,500 (7,800-23,500)

FTKS71HVM / RKS71HVM

Model

Cooling
Capacity

kW

Btu/h

7.1 (2.7-8.7)
24,200 (9,200-29,700)

FTKS85HVM / RKS85HVM

Model

Cooling
Capacity

kW

Btu/h

8.5 (3.0-9.7)
29,000 (10,200-33,100)

Product Lineup

Note:

indicates a new capacity model.         indicates a new design model.

2.46 (1.2-3.0)
8,400 (4,100-10,200)

3.34 (1.2-3.8)
11,400 (4,100-12,950)

Summary of Contents for PCRPH1308

Page 1: ... re or explosion Use only those parts and accessories supplied or speci ed by Daikin Ask a quali ed installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage electrical shock re or explosion Read the User s Manual carefully before using this product The User s...

Page 2: ...ty for each room size The 5 0 to 8 5 kW models also feature a new design The DC Inverter air conditioners achieve high COPs of 3 31 or more thanks to their swing compressor with Reluctance DC motor COP FTKS25G RKS25EB 4 10 FTKS35G RKS35EB 3 31 FTKS50H RKS50H 3 85 FTKS60H RKS60H 3 68 COP COP FTKS71H RKS71H 3 45 FTKS85H RKS85H 3 35 What is COP An air conditioner s COP Coefficient of Performance indi...

Page 3: ...apacity kW Btu h 5 2 1 7 6 2 17 700 5 800 21 200 FTKS60HVM RKS60HVM Model Cooling Capacity kW Btu h 6 0 2 3 6 9 20 500 7 800 23 500 FTKS71HVM RKS71HVM Model Cooling Capacity kW Btu h 7 1 2 7 8 7 24 200 9 200 29 700 FTKS85HVM RKS85HVM Model Cooling Capacity kW Btu h 8 5 3 0 9 7 29 000 10 200 33 100 Product Lineup Note indicates a new capacity model indicates a new design model 2 46 1 2 3 0 8 400 4 ...

Page 4: ... Reluctance DC motor Swing compressor Thanks to its smooth rotation the swing compressor decreases friction and vibration It also prevents the leakage of refrigerant gas during compression These advantages provide quiet and efficient compression PAM Pulse Amplitude Modulation control reduces energy loss by controlling how often the converter switches on and off Inverters are devices that are able ...

Page 5: ... this function Intelligent Eye Outdoor Unit Quiet Operation 3 dB A RKS25EB Operations Rated H Quiet SL Sound pressure levels 46 dB A 43 dB A 3 dB A Selects fan speed and Indoor Unit Quiet Operation Indoor Unit Quiet Operation icon Outdoor Unit Quiet Operation The Intelligent Eye indicator lights when movement is detected Intelligent Eye sensor Intelligent Eye button Econo Mode button When you are ...

Page 6: ...s From a corner to the centre Covers even a spacious room Vertical Auto Swing up and down Horizontal Auto Swing left and right 3 D Airflow Comfort Airflow Mode prevents uncomfortable drafts from blowing directly on to your body With this function when you press the COMFORT button the flap moves upward to prevent direct cold drafts This function is available for 5 0 to 8 5 kW models Comfort Airflow...

Page 7: ...eria are only effective for substances that are collected on and in direct contact with the Titanium Apatite Photocatalytic Air Purifying Filter Apatite adsorbs bacteria At the same time the photocatalyst oxidises odour components breaking them down Effect of Titanium Apatite Photocatalyst Titanium Apatite Photocatalyst Odours Bacteria Decomposed Decomposed Light Adsorbs Removes Cleanliness and Du...

Page 8: ...the wireless remote controller The On timer and Off timer can be used in combination Pressing the Off timer button automatically selects Night Set Mode This function prevents excessive cooling for a pleasant sleep Room temperature is raised by 0 5 C after 60 minutes The air conditioner memorises the settings for mode airflow temperature etc and automatically returns to them when power is restored ...

Page 9: ...sions H x W x D Machine weight Outdoor unit Casing colour Compressor Refrigerant charge R 410A Sound pressure level H SL Dimensions H x W x D Machine weight Operation range Piping connection Max piping length Max height difference Rated Min Max Rated Rated Rated Motor output FTKS25GVMA RKS25EBVMA 2 46 1 2 3 0 8 400 4 100 10 200 3 5 600 4 10 FTKS25GVMA 8 7 307 37 25 22 RKS25EBVMA 46 43 FTKS35GVMA R...

Page 10: ...nd other devices should be obtained locally 4 The filter is a standard accessory It should be replaced approximately every 3 years No 1 2 3 4 5 6 FTKS71 85H KAF970A48 FTKS50 60H KRC72 KRP413AB1S KKF917A4 FTKS25 35G BRC944B2 BRCW901A03 BRCW901A08 1 2 3 4 Specifications are subject to change Item Wired remote controller Wired remote controller cord 5 room centralised controller Wiring adaptor for ti...