3-36
3.5 Battery
3.5.1 Specifications
DECOS
3
c controller can use two types of batteries; DRY or Rechargeable (Optional). It is not possible to
exchange the type of battery afterwards.
The battery is positioned on CPU & I/O box in controller box.
DRY Battery: 9V block battery. (This can be purchased locally.)
Rechargeable: DAIKIN original rechargeable battery
3.5.2 Function
This battery is used without main power supply for the following functions.
1) Display wake up (Refer to chapter 3.3.2) page 3-11.
Setting/Display the following items on the LCD display.
<Display>
Temperature on the return air sensor
Temperature on the supply air sensor
<Setting change>
Inside temperature, defrosting interval, dehumidifying set (Optional), Unit ON/OFF
2) USDA data log
USDA sensors data log every 1 hour
Note) When the Alkaline battery is equipped, it must be replaced for a new every PTI, when USDA is
used.
3) Trip data log
Trip data; Setting point, Supply air, Return air, Humidity and time is logged every 1 hour after power off
until battery run out. (Min. 3 days)
2) USDA data log
3) Trip data log
DRY Battery
(Standard)
1) Display wake up
Rechargeable
(Optional)
: Available : Not available