Netware 2 - Wired Wall Control (Optional)
Error codes blink on wall control display as follows:
E1 - Room sensor loose or defective.
E2 - Indoor coil sensor loose or defective.
E3 - Outdoor coil sensor loose or defective.
E4 - Compressor cycling on overload.
E5 - Low refrigerant charge.
Optional Wired
Wall Control
Air Filters
Air Intake Grille
Air Discharge
Grille
IR Receiver
and LED
Indicator Lights
Air Discharge
Swing Baffle
Wireless Remote
Control
INDOOR UNIT
Cool
Dry
Fan
Cool
Dry
Fan
Heat
Cooling Unit
Cool
Dry
Fan
Heat
Mode or Fault
Cooling mode
Dry mode
Fan mode
Heat mode
Auto mode in heating operation.
Auto mode in cooling operation.
Defrost operation
Compressor overload protection
Outdoor coil sensor contact loose/short
Room air sensor contact loose/short