IM 1193 / Page 9 of 32
Figure 9: 16" x 42" optional recessed louver wall sleeve with continuous flange and drip edge
16"
42"
D**
Louver Mounting Holes
Flange Height
(Standard = 1-1/4")
Flange location (from outdoor side of sleeve)
is factory provided in increments of 1/8"
X*
Drip Edge
Notes:
1. Caulk entire perimeter of wall sleeve after installation.
2. Seal area between louver and wall sleeve to prevent condenser air recirculation.
** See
"Table 1: Cabinet & wall sleeve dimensions" on page 5
for dimension "D".
* Dimension “X” is field determined or specified. Flange is factory welded at given dimension when option is designated.
Figure 10: Wall sleeve installation using top angles and field supplied louver
13
3
⁄
4
"
(349mm)
1
1
⁄
4
"
(38mm)
Insulated
Panel
Optional
Top Flange
16"
(406mm)
Outside Edge
of Sleeve
Wall Sleeve
Turndown
Flange
(See Detail)
Finished Floor
Including Carpet
Outside
Louver
By Others
Resilient
Caulking
(see Note 2)
Turndown Flange
Resilient
Caulking
(see Note 2)
Wall
Sleeve
Wall Frame
By Others
Optional
Top Flange
42"
(1069mm)
Optional
Subbase
16"
(406mm)
10
1
⁄
2
"
(267mm)
Max.
1"
(25mm)
3" Min.
(76mm)
Wall
Sleeve
Insulated Panel
X*
Supports
By Others
(2 Req’d.)
Min. 3
7
⁄
8
"
(98mm)
Notes:
1. Caulk entire perimeter of wall sleeve after installation.
2. Seal area between louver and wall sleeve to prevent condenser air recirculation.
3. Dimensions shown in Table 1 page 5 do not apply to this application.
* Dimension “X” is field determined or specified. Flange is factory welded at given dimension when option is designated.