EDUS391437-F15
Specifications
FXUQ-PVJU
3
2. Specifications
4-Way Blow Ceiling-Suspended Type
Notes:
+
1. Nominal cooling capacities are based on the following conditions:
Return air temperature: 80.0°FDB (26.7°CDB), 67.0°FWB (19.4°CWB)
Outdoor temperature: 95.0°FDB (35.0°CDB)
Equivalent ref. piping length: 25ft (7.6m) (Horizontal)
+
2. Nominal heating capacities are based on the following conditions:
Return air temperature: 70.0°FDB (21.1°CDB).
Outdoor temperature: 47.0°FDB (8.3°CDB), 43.0°FWB (6.1°CWB)
Equivalent ref. piping length: 25ft (7.6m) (Horizontal)
+
3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
+
4. Anechoic chamber conversion value, measured under JIS conditions. During actual operation,
these values may be higher as a result of installation conditions.
5. Refer to
Electric Characteristics
for the power input.
Model
FXUQ18PVJU
FXUQ24PVJU
Power supply
1 phase, 60Hz, 208/230V
1 phase, 60Hz, 208/230V
+
1
+
3 Cooling capacity
Btu/h
(kW)
18,000 (5.3)
24,000 (7.0)
+
2
+
3 Heating capacity
Btu/h
(kW)
20,000 (5.9)
27,000 (7.9)
Casing / Color
Resin/Fresh White
Resin/Fresh White
Dimensions: (H×W×D)
in.
(mm)
7-13/16×37-3/8×37-3/8
(198×950×950)
7-13/16×37-3/8×37-3/8
(198×950×950)
Coil (Cross
fin coil)
Rows×Stages×FPI
3×10×21
3×10×21
Face area
ft
2
(m
2
)
3.55 (0.330)
3.55 (0.330)
Fan
Model
QTS48D11M
QTS48D11M
Type
Turbo fan
Turbo fan
Motor output
W
46
46
Airflow rate (H/M/L)
cfm
(m
3
/min)
795/689/565 (22.5/19.5/16.0)
795/689/565 (22.5/19.5/16.0)
Drive
Direct drive
Direct drive
Temperature control
Microprocessor thermostat
for cooling and heating
Microprocessor thermostat
for cooling and heating
Sound absorbing thermal insulation material
Polyethylene foam
Polyethylene foam
Weight
lbs (kg)
58 (26)
58 (26)
+
4 Sound pressure level (H/M/L)
(Reference data)
dB (A)
40/38/36
40/38/36
+
4 Sound power level (H/M/L)
(Reference data)
dB (A)
58/56/54
58/56/54
Piping
connections
Liquid pipes
in.
(mm)
φ
1/4 (6.4) (Flare connection)
φ
3/8 (9.5) (Flare connection)
Gas pipes
in.
(mm)
φ
1/2 (12.7) (Flare connection)
φ
5/8 (15.9) (Flare connection)
Drain pipe
in.
(mm)
VP20
External dia. 1 (26)
Internal dia. 13/16 (20)
VP20
External dia. 1 (26)
Internal dia. 13/16 (20)
Safety devices
Fuse
Fuse
Refrigerant control
Electronic expansion valve
Electronic expansion valve
Connectable outdoor unit
R410A
VRV
series
R410A
VRV
series
Standard accessories
Operation manual, Installation manual, Paper pattern for
installation, Drain hose, Sealing pads, Clamps, Washers,
Screws, Insulation for fitting, Clamp metal, Conduit mounting
plate
Operation manual, Installation manual, Paper pattern for
installation, Drain hose, Sealing pads, Clamps, Washers,
Screws, Insulation for fitting, Clamp metal, Conduit mounting
plate
Drawing No.
C: 3D090219A
C: 3D090219A
(
)
(
)
Summary of Contents for FXUQ PVJU Series
Page 1: ...EDUS391437 F15 FXUQ PVJU 4 Way Blow Ceiling Suspended Type ...
Page 2: ......
Page 14: ...Sound Levels Reference Data EDUS391437 F15 12 FXUQ PVJU FXUQ30PVJU FXUQ36PVJU 4D090215A ...
Page 36: ...Installation Manual EDUS391437 F15 34 FXUQ PVJU C 3P161684 8T ...
Page 40: ...Detail of Optional Accessories EDUS391437 F15 38 FXUQ PVJU 1P383776 1 ...
Page 41: ...EDUS391437 F15 Detail of Optional Accessories FXUQ PVJU 39 1P383776 1 ...
Page 42: ......
Page 43: ......