VRV SYSTEM Inverter Air Conditioners

Installation manual

CONTENTS

1. SAFETY PRECAUTIONS................................................ 1
2. BEFORE INSTALLATION................................................ 2
3. SELECTING INSTALLATION SITE ................................. 3
4. PREPARATIONS BEFORE INSTALLATION ................... 3
5. INDOOR UNIT INSTALLATION....................................... 4
6. REFRIGERANT PIPING WORK ..................................... 4
7. DRAIN PIPING WORK .................................................... 7
8. ELECTRIC WIRING WORK ............................................ 7
9. WIRING EXAMPLE AND HOW TO SET 

THE REMOTE CONTROLLER ....................................... 8

10. FIELD SETTING............................................................ 10

11. TEST OPERATION ........................................................11

The original instructions are written in English. All other 
languages are translations of the original instructions.

1. SAFETY PRECAUTIONS

Be sure to follow this “SAFETY PRECAUTIONS”. 
This product comes under the term “appliances not accessible 
to the general public”.
This is a class A product. In a domestic environment this 
product may cause radio interference in which case the user 
may be required to take adequate measures.

This manual classifies the precautions into WARNINGS and 
CAUTIONS.
Be sure to follow all the precautions below: They are all 
important for ensuring safety.

WARNING

  ............ Indicates a potentially hazardous 

situation which, if not avoided, could 
result in death or serious injury.

CAUTION

 .............. Indicates a potentially hazardous 

situation which, if not avoided, may 
result in minor or moderate injury.
It may also be used to alert against 
unsafe practices.

• After the installation is completed, test the air conditioner and 

check if the air conditioner operates properly. Give the user 
adequate instructions concerning the use and cleaning of the 
indoor unit according to the Operation Manual. Ask the user 
to keep this manual and the Operation Manual together in a 
handy place for future reference.

WARNING

• Ask your local dealer or qualified personnel to carry out 

installation work.
Improper installation may result in water leakage, electric 
shocks or a fire.

• Perform installation work in accordance with this installation 

manual.
Improper installation may result in water leakage, electric 
shocks or a fire.

• Consult your local dealer regarding what to do in case of 

refrigerant leakage.
When the air conditioner is installed in a small room, it is 
necessary to take proper measures so that the amount of 
any leaked refrigerant does not exceed the concentration 
limit in the event of a leakage.

Otherwise, this may lead to an accident due to oxygen 
deficiency.

• Be sure to use only the specified parts and accessories for 

installation work.
Failure to use the specified parts may result in the air 
conditioner falling down, water leakage, electric shocks, a 
fire, etc.

• Install the air conditioner on a foundation that can withstand 

its mass.
Insufficient strength may result in the air conditioner falling 
down and causing injury.
In addition, it may lead to vibration of indoor units and cause 
unpleasant chattering noise.

• Carry out the specified installation work in consideration of 

strong winds, typhoons, or earthquakes. Improper 
installation may result in an accident such as air conditioner 
falling.

• Make certain that all electrical work is carried out by qualified 

personnel according to the applicable legislation (note 1) and 
this installation manual, using a separate circuit.
In addition, even if the wiring is short, make sure to use a 
wiring that has sufficient length and never connect additional 
wiring to make the length sufficient.
Insufficient capacity of the power supply circuit or improper 
electrical construction may lead to electric shocks or a fire.
(note 1) applicable legislation means “All international, 

national and local directives, laws, regulations 
and/or codes which are relevant and applicable for 
a certain product or domain”.

• Earth the air conditioner.

Do not connect the earth wiring to gas or water piping, 
lightning conductor or telephone earth wiring.
Incomplete earthing may cause electric shocks or a fire.
A high surge current from lightning or other sources may 
cause damage to the air conditioner.

• Be sure to install an earth leakage circuit breaker.

Failure to do so may cause electric shocks and a fire.

• Disconnect the power supply before touching the electric 

components.
If you touch the live part, you may get an electric shocks.

• Make sure that all wiring is secure, using the specified wiring 

and ensuring that external forces do not act on the terminal 
connections or wiring.
Incomplete connection or fixing may cause an overheat or a 
fire.

• When wiring between the indoor and outdoor units, and 

wiring the power supply, form the wiring orderly so that the 
control box lid can be securely fastened.
If the control box lid is not in place, overheat of the terminals, 
electric shocks or a fire may be caused.

• If refrigerant gas leaks during installation work, ventilate the 

area immediately.
Toxic gas may be produced if refrigerant gas comes into 
contact with a fire.

• After completing the installation work, check to make sure 

that there is no leakage of refrigerant gas.
Toxic gas may be produced if refrigerant gas leaks into the 
room and comes into contact with a source of a fire, such as 
a fan heater, stove or cooker.

• Never directly touch any accidental leaking refrigerant. This 

could result in severe wounds caused by frostbite.

4PEN408655-1B_2016_02.book  Page 1  Friday, February 19, 2016  1:33 PM

Summary of Contents for FXTQ80A7VEB

Page 1: ...INSTRUCTIONS CAREFULLY BEFORE INSTALLATION KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE MODELS Ceiling mounted Duct type FXTQ80A7VEB FXTQ100A7VEB SYSTEM Inverter Air Conditioners INSTALLATI...

Page 2: ...a tal como estabelecido em A e com o parecer positivo de B de acordo com o Certificado C 09 A B C 10 Bem rk som anf rt i A og positivt vurderet af B i henhold til Certifikat C 11 Information enligt A...

Page 3: ...leakage electric shocks a fire etc Install the air conditioner on a foundation that can withstand its mass Insufficient strength may result in the air conditioner falling down and causing injury In ad...

Page 4: ...to the unit When moving the unit at or after opening hold the unit by the hanger brackets 4 Do not apply force to the refrigerant piping drain piping or plastic parts For the installation of an outdoo...

Page 5: ...the ceiling is strong enough to support the weight of the unit or not If there is a risk reinforce the ceiling before installing the unit 4 PREPARATIONS BEFORE INSTALLATION 1 Relative positions of in...

Page 6: ...ant insulation 20 mm or thicker Condensation may form on the surface of the insulating material Before refrigerant piping work check which type of refrigerant is used Proper operation is not possible...

Page 7: ...contains fluorine it will damage the refrigerant oil Before brazing local refrigerant piping nitrogen gas shall be blown through the piping to expel air from the piping If your brazing is done without...

Page 8: ...nit Selection of refrigerant branch kits Refnet headers and Refnet joints Refnet joints Outdoor unit FXTQ100 FXTQ80 RYYQ12T 4x O RYYQ14T 2x O 2x O RYYQ16T 4x O RXYQ12T 4x O RXYQ14T 2x O 2x O RXYQ16T 4...

Page 9: ...the drain pipes and corrode the heat exchanger 8 ELECTRIC WIRING WORK 8 1 GENERAL INSTRUCTIONS All field supplied parts and materials and electric works must conform to local codes Use copper wire on...

Page 10: ...through holes to prevent damage to them Make sure the remote controller wiring the wiring between the units and other electrical wiring do not pass through the same locations outside of the unit separ...

Page 11: ...id Make sure the lid closes tight Incomplete connections could result in overheating and in worse case electric shock or fire 9 2 WIRING EXAMPLE Fit the power supply wiring of each unit with a switch...

Page 12: ...rom the remote controller according to the installation state Carry out setting at 3 places Mode No FIRST CODE No and SECOND CODE No The settings shown by in the table indicate those when shipped from...

Page 13: ...it If any of the items in Table 7 are displayed there may be a problem with the wiring or power so check the wiring again Table 7 Setting Mode No FIRST CODE No SECOND CODE No Standard E S P 13 23 6 1...

Page 14: ......

Page 15: ......

Page 16: ...4P408655 1B 2016 02 Copyright 2015 Daikin...

Reviews: