![background image](http://html2.mh-extra.com/html/daikin/fxsq05tavju/fxsq05tavju_engineering-data_4700804062.webp)
Installation Manual
EDUS391777-F17
7
FXSQ-TAVJU
3P184443-13Z
7
English
V[RG
5WEVKQPƃCPIG
4GRNCEGOGPV
%JCODGTEQXGT
V[RG
Replacement
5WEVKQPƃCPIG
Chamber cover
Note)
1. Be sure to remove chamber cover one side by
one side.
(QTVJKUOQFGNOCKPVGPCPEGQHVJGEQPVTQNDQZ
through side is only available.
Maintenance through bottom is not available.
Fig. 5
5. INSTALLATION OF INDOOR UNIT
Depending on the optional accessories, it may be easier
to attach them before installing the indoor unit. Refer to
also the installation manual attached to the optional ac-
cessories.
(QTKPUVCNNCVKQPWUGVJGCVVCEJGFCPFURGEKƂGFCEEGUUQ
-
ries.
(1)
Install the indoor unit temporarily.
r
(KZVJGJCPIGTVQVJGJCPIKPIDQNV
/CMGUWTGVQUGEWTGN[ƂZVJGJCPIGTYKVJVJGPWVCPF
the washer for hanger (11) from the upper and lower
side.
(Refer to Fig. 6)
If the washer clamp (9) is used, the upper side washer
for hanger (11) may be protected from falling off.
(Refer to Fig. 7)
[ Fix the hanger ]
Field supply
Tighten
(double nut)
Washer for
hanger (11)
(accessory)
Fig. 6
=9CUJGTƂZKPI?
Washer
clamp (9)
(accessory)
+PUGTV
7RRGTPWV
Washer for
JCPIGT
(accessory)
Fig. 7
r
Keep the air outlet covered with a protective sheet to pre-
vent weld spatter and other foreign materials from entering
the indoor unit and damaging the resin drain pan.
(If holes or cracks are generated in the resin drain pan,
water can leak.)
(2)
Adjust so that the unit is properly positioned.
(3)
Check the level of the unit.
(Refer to Fig. 8)
(4)
Remove the washer clamp (9) used for preventing the
washer for hanger (11) from dropping and tighten the up-
per side nut.
Hanger
Bottom of
product
Level
Vinyl tube
[Maintaining horizontality]
Feed water into the tube and
set the indoor unit to the water
levels on the left and right.
Fig. 8
CAUTION
r
Install the indoor unit leveled.
If the indoor unit is inclined and the drain piping side gets
JKIJKVOC[ECWUGOCNHWPEVKQPQHƃQCVUYKVEJCPFTGUWNVKP
water leakage.
r
Attach nuts on the upper and lower side of hanger.
If there is no upper nut and the lower nut is over-tightened,
the hanger and the top plate will deform and cause abnor-
mal sound.
r &QPQVKPUGTVOCVGTKCNUQVJGTVJCPVJCVURGEKƂGFKPVQ
the clearance between the hanger and the washer
for hanger (11).
Unless the washers are properly attached, the hanging
bolts may come off from the hanger.
WARNING
The indoor unit must be securely installed on a
place that can withstand the weight.
+HVJGUVTGPIVJKUKPUWHƂEKGPVVJGKPFQQTWPKVOC[HCNN
down and cause injuries.
Summary of Contents for FXSQ05TAVJU
Page 1: ...EDUS391777 F17 FXSQ TAVJU MSP Concealed Ducted Unit...
Page 2: ......
Page 12: ...Dimensions EDUS391777 F17 10 FXSQ TAVJU FXSQ15TAVJU 3D110731A...
Page 13: ...EDUS391777 F17 Dimensions FXSQ TAVJU 11 FXSQ18TAVJU 3D110732A...
Page 14: ...Dimensions EDUS391777 F17 12 FXSQ TAVJU FXSQ24TAVJU FXSQ30TAVJU 3D110733B...
Page 15: ...EDUS391777 F17 Dimensions FXSQ TAVJU 13 FXSQ36TAVJU FXSQ48TAVJU 3D110734B...
Page 16: ...Dimensions EDUS391777 F17 14 FXSQ TAVJU FXSQ54TAVJU 3D110735B...
Page 24: ...Fan Performance EDUS391777 F17 22 FXSQ TAVJU FXSQ09TAVJU 3D112417...
Page 25: ...EDUS391777 F17 Fan Performance FXSQ TAVJU 23 FXSQ12TAVJU 3D112418...
Page 26: ...Fan Performance EDUS391777 F17 24 FXSQ TAVJU FXSQ15TAVJU 3D112419...
Page 27: ...EDUS391777 F17 Fan Performance FXSQ TAVJU 25 FXSQ18TAVJU 3D112420...
Page 28: ...Fan Performance EDUS391777 F17 26 FXSQ TAVJU FXSQ24TAVJU 3D112421...
Page 29: ...EDUS391777 F17 Fan Performance FXSQ TAVJU 27 FXSQ30TAVJU 3D112422...
Page 30: ...Fan Performance EDUS391777 F17 28 FXSQ TAVJU FXSQ36TAVJU 3D112423...
Page 31: ...EDUS391777 F17 Fan Performance FXSQ TAVJU 29 FXSQ48TAVJU 3D112424...
Page 32: ...Fan Performance EDUS391777 F17 30 FXSQ TAVJU FXSQ54TAVJU 3D112425...
Page 34: ...Airflow Auto Adjustment Characteristics EDUS391777 F17 32 FXSQ TAVJU FXSQ09TAVJU 3D112454...
Page 35: ...EDUS391777 F17 Airflow Auto Adjustment Characteristics FXSQ TAVJU 33 FXSQ12TAVJU 3D112455...
Page 36: ...Airflow Auto Adjustment Characteristics EDUS391777 F17 34 FXSQ TAVJU FXSQ15TAVJU 3D112456...
Page 37: ...EDUS391777 F17 Airflow Auto Adjustment Characteristics FXSQ TAVJU 35 FXSQ18TAVJU 3D112457...
Page 38: ...Airflow Auto Adjustment Characteristics EDUS391777 F17 36 FXSQ TAVJU FXSQ24TAVJU 3D112458...
Page 39: ...EDUS391777 F17 Airflow Auto Adjustment Characteristics FXSQ TAVJU 37 FXSQ30TAVJU 3D112459...
Page 40: ...Airflow Auto Adjustment Characteristics EDUS391777 F17 38 FXSQ TAVJU FXSQ36TAVJU 3D112460...
Page 41: ...EDUS391777 F17 Airflow Auto Adjustment Characteristics FXSQ TAVJU 39 FXSQ48TAVJU 3D112461...
Page 42: ...Airflow Auto Adjustment Characteristics EDUS391777 F17 40 FXSQ TAVJU FXSQ54TAVJU 3D112462...
Page 44: ...Sound Levels Reference Data EDUS391777 F17 42 FXSQ TAVJU FXSQ12TAVJU 4D110413...
Page 45: ...EDUS391777 F17 Sound Levels Reference Data FXSQ TAVJU 43 FXSQ15TAVJU 4D110414...
Page 46: ...Sound Levels Reference Data EDUS391777 F17 44 FXSQ TAVJU FXSQ18TAVJU 4D110415...
Page 47: ...EDUS391777 F17 Sound Levels Reference Data FXSQ TAVJU 45 FXSQ24TAVJU 4D110416...
Page 48: ...Sound Levels Reference Data EDUS391777 F17 46 FXSQ TAVJU FXSQ30TAVJU 4D110417...
Page 49: ...EDUS391777 F17 Sound Levels Reference Data FXSQ TAVJU 47 FXSQ36TAVJU 4D110418...
Page 50: ...Sound Levels Reference Data EDUS391777 F17 48 FXSQ TAVJU FXSQ48TAVJU 4D110419...
Page 51: ...EDUS391777 F17 Sound Levels Reference Data FXSQ TAVJU 49 FXSQ54TAVJU 4D110420...
Page 75: ......