[ For new ceilings ]

(2) Refer to the paper pattern for installation for ceiling 

opening dimension. Consult the builder or carpenter 
for details.

• The center of the ceiling opening is indicated on the 

paper pattern for installation.

• After cutting out a slit for the unit in the center of the paper 

pattern for installation (accessory), install with the 4 
screws (accessory).

• Fold the guide section of paper pattern for installation and 

adjust the height of the unit so the notch in the guide is at 
the position where you expect the ceiling surface to be.

 Ceiling work 

(3) Adjust the unit to the right position for installation. 

(Refer to “

PREPARATIONS BEFORE INSTALLATION-(1)

”.) 

(4) Check the unit is horizontally level.

CAUTION

The indoor unit is equipped with a built-in drain pump 
and float switch. At each of the unit’s 4 corners, verify 
that it is level by using a level or a water-filled vinyl 
tube. (If the unit is inclined against condensate flow, 
the float switch may malfunction and cause water to 
drip.)

(5) Remove the washer fixing plate used for preventing the 

washer from falling and tighten the upper nut.

(6) Remove the paper pattern for installation.

[ For existing ceilings ]

(2) Adjust the height of the unit.

Cut out the guide section of the paper pattern for installation 
attached, place on the bottom surface of the unit, and adjust 
the height of the unit so that the notch of the guide matches 
the lower surface of the ceiling.

(3) Perform steps (3), (4), (5) in For new ceilings.

6.

REFRIGERANT PIPING WORK

• For the outdoor unit refrigerant piping, refer to the installation 

manual attached to the outdoor unit.

• Carry out insulation of both gas and liquid refrigerant piping 

securely. If not insulated, it may cause water leakage. For 
gas piping, use insulation material of which heat resistant 
temperature is not less than 120°C.
For use under high humidity, strengthen the insulation mate-
rial for refrigerant piping. If not strengthened, the surface of 
insulation material may sweat.

• Before installation work, make sure that the refrigerant is 

R410A. (Unless the refrigerant is R410A, the normal opera-
tion cannot be expected.)

CAUTION

This air conditioner is a dedicated model for new refrig-
erant R410A. Make sure to meet the requirements shown 
below and carry out installation work.

Use dedicated piping cutters and flaring tools for 
R410A.

When making a flare connection, coat the flared inner 
surface only with ether oil or ester oil.

Use only the flare nuts attached to the air conditioner. 
If other flare nuts are used, it may cause refrigerant 
leakage.

Part to be procured in the 

fi

eld

[ Securing the hanger bracket ]

Washer (accessory)

Hanger bracket

Tighten
(double nut)

Insert

Washer 

fi

xing plate

(accessory)

[ Securing the washer ]

Cut-out section

Paper pattern
for installation

Screws (× 4 accessory)

(accessory)

[ Installation of paper pattern for installation ]

Guide section (4 corners)

Paper pattern
for installation

Ceiling

Lower 
surface 
of the 
ceiling

[ Unit height adjustment ]

(accessory)

Vinyl tube

Level

The unit body

Ceiling

Lower
surface of 
the ceiling

The guide portion

[ Unit height adjustment ]

01_EN_3P258319-5K.fm  Page 5  Thursday, October 15, 2015  11:03 AM

Summary of Contents for FXCQ20MVE

Page 1: ...AUF VEUILLEZ LIRE ATTENTIVEMENT CES INSTRUCTIONS AVANT L INSTALLATION CONSERVEZ CE MANUEL EN LIEU S R POUR POUVOIR VOUS Y REPORTER ULT RI EUREMENT LEA DETENIDAMENTE ESTAS INSTRUCCIONES ANTES DE LA IN...

Page 2: ...FXHQ63MVE FXHQ100MVE FXSQ20MVE FXSQ25MVE FXSQ32MVE FXSQ40MVE FXSQ50MVE FXSQ63MVE FXSQ80MVE FXSQ100MVE FXSQ125MVE FXKQ25MVE FXKQ32MVE FXKQ40MVE FXKQ63MVE FXAQ20MVE FXAQ25MVE FXAQ32MVE FXAQ40MVE FXAQ50...

Page 3: ...electric shocks a fire etc Install the air conditioner on a foundation that can withstand its mass Insufficient strength may result in the air conditioner falling down and causing injury In addition i...

Page 4: ...or protective plates together with a rope when lifting to avoid damage or scratches to the unit When moving the unit at or after opening hold the unit by the hanger brackets 4 Do not apply force to t...

Page 5: ...llowable limit Refer to the installation manual for the outdoor unit Any vents light fixtures or other appliances which may disturb the airflow might cause the top side to become dirty if located too...

Page 6: ...3 Install the suspension bolts Use either a W3 8 or M10 size bolt Use a hole in anchor for existing ceilings and a sunken insert sunken anchor or other part to be procured in the field for new ceilin...

Page 7: ...m steps 3 4 5 in For new ceilings 6 REFRIGERANT PIPING WORK For the outdoor unit refrigerant piping refer to the installation manual attached to the outdoor unit Carry out insulation of both gas and l...

Page 8: ...g Therefore use the phosphor copper brazing filler metal BCuP 2 JIS Z 3264 B Cu93P 710 795 ISO 3677 which does not require flux Flux has extremely harmful influence on refrigerant piping systems For i...

Page 9: ...RECAUTIONS FOR DRAIN RAISING PIPING Install the drain raising pipes at a height of less than 310 mm Install the drain raising pipes at a right angle to the indoor unit and no more than 300 mm from the...

Page 10: ...he entire system must be installed Refer to the installation manual attached to the outdoor unit for the size of power supply wiring connected to the outdoor unit the capacity of the circuit breaker a...

Page 11: ...arry out soldering finish when stranded wires are used Otherwise the loosening of wires may result in abnor mal heat radiation Abnormal heating may occur if the wirings are not tightened securely Use...

Page 12: ...the upper part The remote controller PC board is attached to the upper part of remote controller Power supply wiring Transmission wiring Switch Fuse Power supply Main switch Remote controller Indoor...

Page 13: ...door units or to check the setting use the mode Nos with 2 in upper digit in parentheses Set the remote controller to the field set mode For details refer to the HOW TO SET IN THE FIELD in the remote...

Page 14: ...1511 HT 3P258319 5K EM02A084C...

Reviews: