WIRING EXAMPLE 

• Fit the power supply wiring of each unit with a switch and fuse 

as shown in the drawing. 

COMPLETE SYSTEM EXAMPLE (3 systems)

 

1. When using 1 remote controller for 1 indoor unit. (Nor-

mal operation)

2. For group control or use with 2 remote controllers

3. When including BS unit

NOTE

• It is not necessary to designate indoor unit address when 

using group control. The address is automatically set when 
power is activated.

[ PRECAUTIONS ] 

1. A single switch can be used to supply power to units on the 

same system. However, branch switches and branch circuit 
breakers must be selected carefully. 

2. Do not ground the equipment on gas pipes, water pipes or 

lightning rods, or crossground with telephones. Improper 
grounding could result in electric shock.

9-3

CONTROL BY 2 REMOTE CONTROLLERS (Con-
trolling 1 indoor unit by 2 remote controllers)

• When using 2 remote controllers, one must be set to “MAIN” 

and the other to “SUB”.

MAIN/SUB CHANGEOVER

(1) Insert a 

 screw driver into the recess between the 

upper and lower part of remote controller and, working 
from the 2 positions, pry off the upper part. 

The remote controller PC board is attached to the upper 
part of remote controller.

 

Power supply wiring

Transmission wiring

Switch

Fuse

Power supply

Main
switch

Remote controller

Indoor unit

BS unit
(Only for Heat
recovery 
system)

L N

IN/D OUT/D

F

1

F

2

F

1

F

2

Control box

L N

P

1

P

2

P

1

P

2

F

1

F

2

T

1

T

2

P

1

P

2

P

1

P

2

F

1

F

2

T

1

T

2

L N

P

1

P

2

P

1

P

2

F

1

F

2

T

1

T

2

L N

L N

P

1

P

2

P

1

P

2

F

1

F

2

T

1

T

2

Outdoor unit

No. 1 System

Indoor 
unit A

Indoor 
unit B

Indoor 
unit C

Most
downstream
Indoor unit 

Power supply

220-240V

50Hz

or

220V

60Hz

IN/D OUT/D

F1 F2 F1 F2

Control box

L N

P

1

P

2

P

1

P

2

F

1

F

2

T

1

T

2

L N

P

1

P

2

F

1

F

2

T

1

T

2

L N

P

1

P

2

F

1

F

2

T

1

T

2

L N

P

1

P

2

F

1

F

2

T

1

T

2

P

1

P

2

P

1

P

2

L N

Outdoor unit

No. 2
System

Indoor unit A

Indoor unit B

Indoor unit C

Most 
downstream
indoor unit

For use with 2
remote controllers

Power supply

220-240V

50Hz

or

220V

60Hz

Fig. 6

IN/D OUT/D

F1 F2 F1 F2

IN/D

OUT/D

F1 F2 F1 F2

L N

P

1

P

2

P

1

P

2

F

1

F

2

T

1

T

2

BS unit

No. 3
System

Outdoor unit

Power 

supply

220-240V

50Hz

or

220V

60Hz

Indoor unit A

Most 
downstream
indoor unit

Control box

Control box

IN/D

OUT/D

F1 F2 F1 F2

BS unit

Control box

P

1

P

2

P

1

P

2

F

1

F

2

T

1

T

2

L N

L N

Upper part of 
remote controller

Lower part of 
remote controller

Insert the screwdriver here and gently work 
off the upper part of remote controller.

01_EN_3P258319-5K.fm  Page 10  Thursday, October 15, 2015  11:03 AM

Summary of Contents for FXCQ20MVE

Page 1: ...AUF VEUILLEZ LIRE ATTENTIVEMENT CES INSTRUCTIONS AVANT L INSTALLATION CONSERVEZ CE MANUEL EN LIEU S R POUR POUVOIR VOUS Y REPORTER ULT RI EUREMENT LEA DETENIDAMENTE ESTAS INSTRUCCIONES ANTES DE LA IN...

Page 2: ...FXHQ63MVE FXHQ100MVE FXSQ20MVE FXSQ25MVE FXSQ32MVE FXSQ40MVE FXSQ50MVE FXSQ63MVE FXSQ80MVE FXSQ100MVE FXSQ125MVE FXKQ25MVE FXKQ32MVE FXKQ40MVE FXKQ63MVE FXAQ20MVE FXAQ25MVE FXAQ32MVE FXAQ40MVE FXAQ50...

Page 3: ...electric shocks a fire etc Install the air conditioner on a foundation that can withstand its mass Insufficient strength may result in the air conditioner falling down and causing injury In addition i...

Page 4: ...or protective plates together with a rope when lifting to avoid damage or scratches to the unit When moving the unit at or after opening hold the unit by the hanger brackets 4 Do not apply force to t...

Page 5: ...llowable limit Refer to the installation manual for the outdoor unit Any vents light fixtures or other appliances which may disturb the airflow might cause the top side to become dirty if located too...

Page 6: ...3 Install the suspension bolts Use either a W3 8 or M10 size bolt Use a hole in anchor for existing ceilings and a sunken insert sunken anchor or other part to be procured in the field for new ceilin...

Page 7: ...m steps 3 4 5 in For new ceilings 6 REFRIGERANT PIPING WORK For the outdoor unit refrigerant piping refer to the installation manual attached to the outdoor unit Carry out insulation of both gas and l...

Page 8: ...g Therefore use the phosphor copper brazing filler metal BCuP 2 JIS Z 3264 B Cu93P 710 795 ISO 3677 which does not require flux Flux has extremely harmful influence on refrigerant piping systems For i...

Page 9: ...RECAUTIONS FOR DRAIN RAISING PIPING Install the drain raising pipes at a height of less than 310 mm Install the drain raising pipes at a right angle to the indoor unit and no more than 300 mm from the...

Page 10: ...he entire system must be installed Refer to the installation manual attached to the outdoor unit for the size of power supply wiring connected to the outdoor unit the capacity of the circuit breaker a...

Page 11: ...arry out soldering finish when stranded wires are used Otherwise the loosening of wires may result in abnor mal heat radiation Abnormal heating may occur if the wirings are not tightened securely Use...

Page 12: ...the upper part The remote controller PC board is attached to the upper part of remote controller Power supply wiring Transmission wiring Switch Fuse Power supply Main switch Remote controller Indoor...

Page 13: ...door units or to check the setting use the mode Nos with 2 in upper digit in parentheses Set the remote controller to the field set mode For details refer to the HOW TO SET IN THE FIELD in the remote...

Page 14: ...1511 HT 3P258319 5K EM02A084C...

Reviews: