background image

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,

Kita-ku, Osaka, 530-8323 J

apan

D

AIKIN INDUSTRIES,

 L

TD

.

EN60335-2-40,

D

AIKIN.TCF

.022E1/10-2007

TÜV Rheinlar

d EPS B.V

.

0305020101

3P109591-1E

Shinr

i Sada

Manager Quality Control Depar

tment

1st of Ma

y 2009

Lo

w V

oltage 

2006/95/EC

Machiner

y Saf

ety 98/37/EC

Electromagnetic Compatibility 2004/108/EC

FXZQ20MVE, FXZQ25MVE, FXZQ32MVE, FXZQ40MVE, FXZQ50MVE

FXCQ20MVE, FXCQ25MVE, FXCQ32MVE, FXCQ40MVE, FXCQ50MVE, FXCQ63MVE, FXCQ80MVE, FXCQ125MVE

FXMQ40MVE, FXMQ50MVE, FXMQ63MVE, FXMQ80MVE, FXMQ100MVE, FXMQ125MVE, FXMQ200MVE, FXMQ250MVE

FXLQ20MVE, FXLQ25MVE, FXLQ32MVE, FXLQ40MVE, FXLQ50MVE, FXLQ63MVE

FXNQ20MVE, FXNQ25MVE, FXNQ32MVE, FXNQ40MVE, FXNQ50MVE, FXNQ63MVE

FXHQ32MVE, FXHQ63MVE, FXHQ100MVE

FXSQ20MVE, FXSQ25MVE, FXSQ32MVE, FXSQ40MVE, FXSQ50MVE, FXSQ63MVE, FXSQ80MVE, FXSQ100MVE, FXSQ125MVE

FXKQ25MVE, FXKQ32MVE, FXKQ40MVE, FXKQ63MVE

FXAQ20MVE, FXAQ25MVE, FXAQ32MVE, FXAQ40MVE, FXAQ50MVE, FXAQ63MVE

FXUQ71MV1, FXUQ100MV1, FXUQ125MV1

BEVQ71MVE, BEVQ100MVE, BEVQ125MVE

FXMQ125MFV1, FXMQ200MFV1, FXMQ250MFV1

FXAQ20MHV1, FXAQ25MHV1, FXAQ32MHV1, FXAQ40MHV1, FXAQ50MHV1

BEVQ50MVE

FXLQ20MHV1, FXLQ25MHV1, FXLQ32MHV1, FXLQ40MHV1, FXLQ50MHV1,

FXMQ40MAVE, FXMQ50MAVE, FXMQ63MAVE, FXMQ80MAVE

FXMQ100MAVE, FXMQ125MAVE, FXMQ200MAVE, FXMQ250MAVE

FXLQ20MAVE, FXLQ25MAVE, FXLQ32MAVE, FXLQ40MAVE

FXLQ50MAVE, FXLQ63MAVE

FXNQ20MAVE, FXNQ25MAVE, FXNQ32MAVE, FXNQ40MAVE

FXNQ50MAVE, FXNQ63MAVE

FXHQ32MAVE, FXHQ63MAVE, FXHQ100MAVE

FXKQ25MAVE, FXKQ32MAVE, FXKQ40MAVE, FXKQ63MAVE

FXAQ20MAVE, FXAQ25MAVE, FXAQ32MAVE, FXAQ40MAVE

FXAQ50MAVE, FXAQ63MAVE

FXUQ71MAV1, FXUQ100MAV1, FXUQ125MAV1

BEVQ71MAVE, BEVQ100MAVE, BEVQ125MAVE

3P109591-1E.fm  Page 1  Saturday, April 18, 2009  10:25 AM

Summary of Contents for FXCQ20MVE

Page 1: ...AUF VEUILLEZ LIRE ATTENTIVEMENT CES INSTRUCTIONS AVANT L INSTALLATION CONSERVEZ CE MANUEL EN LIEU S R POUR POUVOIR VOUS Y REPORTER ULT RI EUREMENT LEA DETENIDAMENTE ESTAS INSTRUCCIONES ANTES DE LA IN...

Page 2: ...FXHQ63MVE FXHQ100MVE FXSQ20MVE FXSQ25MVE FXSQ32MVE FXSQ40MVE FXSQ50MVE FXSQ63MVE FXSQ80MVE FXSQ100MVE FXSQ125MVE FXKQ25MVE FXKQ32MVE FXKQ40MVE FXKQ63MVE FXAQ20MVE FXAQ25MVE FXAQ32MVE FXAQ40MVE FXAQ50...

Page 3: ...electric shocks a fire etc Install the air conditioner on a foundation that can withstand its mass Insufficient strength may result in the air conditioner falling down and causing injury In addition i...

Page 4: ...or protective plates together with a rope when lifting to avoid damage or scratches to the unit When moving the unit at or after opening hold the unit by the hanger brackets 4 Do not apply force to t...

Page 5: ...llowable limit Refer to the installation manual for the outdoor unit Any vents light fixtures or other appliances which may disturb the airflow might cause the top side to become dirty if located too...

Page 6: ...3 Install the suspension bolts Use either a W3 8 or M10 size bolt Use a hole in anchor for existing ceilings and a sunken insert sunken anchor or other part to be procured in the field for new ceilin...

Page 7: ...m steps 3 4 5 in For new ceilings 6 REFRIGERANT PIPING WORK For the outdoor unit refrigerant piping refer to the installation manual attached to the outdoor unit Carry out insulation of both gas and l...

Page 8: ...g Therefore use the phosphor copper brazing filler metal BCuP 2 JIS Z 3264 B Cu93P 710 795 ISO 3677 which does not require flux Flux has extremely harmful influence on refrigerant piping systems For i...

Page 9: ...RECAUTIONS FOR DRAIN RAISING PIPING Install the drain raising pipes at a height of less than 310 mm Install the drain raising pipes at a right angle to the indoor unit and no more than 300 mm from the...

Page 10: ...he entire system must be installed Refer to the installation manual attached to the outdoor unit for the size of power supply wiring connected to the outdoor unit the capacity of the circuit breaker a...

Page 11: ...arry out soldering finish when stranded wires are used Otherwise the loosening of wires may result in abnor mal heat radiation Abnormal heating may occur if the wirings are not tightened securely Use...

Page 12: ...the upper part The remote controller PC board is attached to the upper part of remote controller Power supply wiring Transmission wiring Switch Fuse Power supply Main switch Remote controller Indoor...

Page 13: ...door units or to check the setting use the mode Nos with 2 in upper digit in parentheses Set the remote controller to the field set mode For details refer to the HOW TO SET IN THE FIELD in the remote...

Page 14: ...1511 HT 3P258319 5K EM02A084C...

Reviews: