background image

4

English

If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the 
air conditioner may not operate, or sometimes, 
water may drop from the indoor unit.
COOLING                                                              [°C]

HEATING                                                             [°C]

D

 

B: Dry bulb temperature

WB: Wet bulb temperature

The setting temperature range of the control panel is 
16°C to 32°C.

Regarding places for installation

• Is the air conditioner installed at a well-ventilated 

place where there are no obstacles around?

• Ensure that the remote controller is not 

exposed to direct sunlight.
This will cause discoloration of the LCD dis-
play with resulting loss of readability.

• Do not use the air conditioner in the following 

places.

a.Filled with much mineral oil such as cutting oil
b.Where there is much salt such as a beach area
c.Where sulfured gas exists such as a hot-spring 

resort

d.Where there are considerable voltage fluctua-

tions such as a factory or plant

e.Vehicles and vessels

 

f

 

.Where there is much spray of oil and vapor such 

as a cookery, etc.

g.Where there are machines generating electro-

magnetic waves

h.Filled with acid and/or alkaline steam or vapor

• Is a snow protection measure taken?

For details, consult your dealer.

3. OPERATION RANGE

OUTDOOR 

UNIT

INDOOR

OUTDOOR 

TEMPERA-

TURE

TEMPERA-

TURE

HUMI-

DITY

RZQS71 · 100 ·
         125

D

B

18 to 37

80% 

or 

below

D

B

–15 to 50

W

B

12 to 28

OUTDOOR 

UNIT

INDOOR 

TEMPERA-

TURE

OUTDOOR 

TEMPERA-

TURE

RZQS71 · 100 ·
         125

D

B

10 to 27

D

B

–19.5 to 21

W

B

–20 to 15.5

4. INSTALLATION SITE

Regarding wiring

• All wiring must be performed by an authorized 

electrician.

To do wiring, ask your dealer. Never do it by yourself.

• Make sure that a separate power supply circuit 

is provided for this air conditioner and that all 
electrical work is carried out by qualified per-
sonnel according to local laws and regulations.

Pay attention to running noises, too

• Are the following places selected?

a.A place that can sufficiently withstand the 

weight of the air conditioner with less running 
noises and vibrations.

b.A place where the hot wind discharged from the 

air outlet of the outdoor unit and the running 
noises do not bother your neighbors.

• Are you sure that there are no obstacles near 

the air outlet of the outdoor unit?

Such obstacles may result in declined perfor-
mance and increased running noises.

• If abnormal noises occur in use, consult your 

dealer.

Regarding drainage of drain piping

• Is the drain piping executed to perform com-

plete drainage?

If proper drainage is not carried out from the out-
door drain pipes during air-conditioning operation, 
chances are that dust and dirt are clogged in the 
pipe. This may result in a water leakage from the 
indoor unit. Under such circumstances, stop the 
operation of the air conditioner, and then consult 
your dealer or our service station.

 Refer to figure 1 on page [1] 

5. NAME AND FUNCTION OF EACH 

SWITCH AND DISPLAY ON THE 
CONTROL PANEL

1

ON/OFF BUTTON

Press the button and the system will start. 
Press the button again and the system will stop.

2

OPERATION LAMP (RED)

The lamp lights up during operation.

3

DISPLAY “

(UNDER CENTRALIZED CONTROL)

When this display shows, the system is 
UNDER CENTRALIZED CONTROL.
(This is not a standard specification.)

01_EN_3P170549-6F.fm  Page 4  Saturday, December 22, 2007  11:49 AM

Summary of Contents for FVQ71BV1B

Page 1: ...SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Floor standing type FVQ71BV1B FVQ100BV1B FVQ125BV1B English Deutsch Fran ais Espa ol Italiano Nederlands Portugues...

Page 2: ...ar en caso de aver a Despu s de leer el manual con s rvelo para consultas futuras La ringraziamo di aver acquistato questo con dizionatore d aria Daikin Leggere attentamente questo manuale prima di ut...

Page 3: ...AILABLE L H 2 10 11 3 1 4 5 6 7 8 14 15 16 17 18 19 20 21 22 12 9 13 NOTE Never operate remote controller buttons with hard pointed objects This may result in remote controller damage e a f d c i h e...

Page 4: ...eite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalaciones espe...

Page 5: ...S FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one control panel controls one indoor unit system Confirm th...

Page 6: ...r conditioner is to be installed in a small room it is necessary to take proper mea sures so that the amount of any leaked refriger ant does not exceed the concentration limit in the event of a leakag...

Page 7: ...not wash the air conditioner with water as this may result in electric shocks or fire Do not place water containers flower vases etc on the unit as this may result in electric shocks or fire Do not in...

Page 8: ...ring All wiring must be performed by an authorized electrician To do wiring ask your dealer Never do it by yourself Make sure that a separate power supply circuit is provided for this air conditioner...

Page 9: ...ON This button is used only by qualified service persons for maintenance purposes 17 PROGRAMMING TIME BUTTON Use this button for programming START and or STOP time hr hr C Refer to figure 1 on page 1...

Page 10: ...ile When the warm air stays under the ceiling and your feet are cold we recommend that you use a circulator a fan to circulate the air inside the room For details consult your dealer For programming T...

Page 11: ...g the timer Off and On at the same time repeat the above procedure from 1 to 3 once again When the timer is programmed to stop the system after 3 hours and start the system after 4 hours the system wi...

Page 12: ...sh and neutral detergent Remove water and dry in the shade NOTE Do not wash the air conditioner with hot water of more than 50 C as doing so may result in discol oration and or deformation Do not expo...

Page 13: ...AIR CONDITIONER The outdoor unit stops The room temperature has reached the preset temperature The indoor unit is in ventilation oper ation II THE AIR CONDITIONER STOPS OPERATING FROM TIME TO TIME Th...

Page 14: ...set tempera ture See page 6 The AIR FLOW BLADE display on the control panel differs in direction from the actual air flow blade While in heating operation The air conditioner will be in wind direction...

Page 15: ...heck if the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE 3 The system operates but it does not suffi ciently cool or heat If the air inlet or outl...

Page 16: ...3P170549 6F EM07A042A 0802 HT FS...

Reviews: