background image

English

11

II. If the system does not properly operate except 

for the above mentioned case, and none of the 
above mentioned malfunctions is evident, 
investigate the system according to the fol-
lowing procedures.

1. If the system does not operate at all.

Check if there is a power failure.
Wait until power is restored. If power failure 
occurs during operation, the system automati-
cally restarts immediately after the power sup-
ply recovers.

Check if no fuse has blown.
Turn off the power supply.

Check if the breaker is 
blown.
Turn the power on with 
the breaker switch in 
the off position.
Do not turn the power on with the breaker 
switch in the trip position.
(Contact your dealer.)

2. If the system stops operating after operating 

the system.

Check if the air inlet or outlet of outdoor or 
indoor unit is blocked by obstacles.
Remove the obstacle and make it well-venti-
lated.

Check if the air filter is clogged.
Ask a qualified service person to clean the air 
filters (Refer to MAINTENANCE).

3. The system operates but it does not suffi-

ciently cool or heat.

If the air inlet or outlet of the indoor or the out-
door unit is blocked with obstacles.
Remove the obstacle and make it well-venti-
lated. 

If the air filter is clogged.
Ask a qualified service person to clean the air 
filters (Refer to MAINTENANCE).

If the set temperature is not proper (Refer to 
ADJUSTMENT).

If the FAN SPEED button is set to LOW 
SPEED (Refer to ADJUSTMENT).

If the air flow angle is not proper (Refer to 
ADJUSTING THE AIR FLOW DIRECTION).

If the doors or the windows are open. Shut 
doors or windows to prevent wind from coming 
in.

If direct sunlight enters the room (when cool-
ing).
Use curtains or blinds.

When there are too many inhabitants in the 
room (when cooling).
Cooling effect decreases if heat gain of the 
room is too large.

Switch

ON

OFF

Trip position

Breaker

If the heat source of the room is excessive 
(when cooling).
Cooling effect decreases if heat gain of the 
room is too large.

01_EN_3P170549-6F.fm  Page 11  Saturday, December 22, 2007  11:49 AM

Summary of Contents for FVQ71BV1B

Page 1: ...SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Floor standing type FVQ71BV1B FVQ100BV1B FVQ125BV1B English Deutsch Fran ais Espa ol Italiano Nederlands Portugues...

Page 2: ...ar en caso de aver a Despu s de leer el manual con s rvelo para consultas futuras La ringraziamo di aver acquistato questo con dizionatore d aria Daikin Leggere attentamente questo manuale prima di ut...

Page 3: ...AILABLE L H 2 10 11 3 1 4 5 6 7 8 14 15 16 17 18 19 20 21 22 12 9 13 NOTE Never operate remote controller buttons with hard pointed objects This may result in remote controller damage e a f d c i h e...

Page 4: ...eite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalaciones espe...

Page 5: ...S FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one control panel controls one indoor unit system Confirm th...

Page 6: ...r conditioner is to be installed in a small room it is necessary to take proper mea sures so that the amount of any leaked refriger ant does not exceed the concentration limit in the event of a leakag...

Page 7: ...not wash the air conditioner with water as this may result in electric shocks or fire Do not place water containers flower vases etc on the unit as this may result in electric shocks or fire Do not in...

Page 8: ...ring All wiring must be performed by an authorized electrician To do wiring ask your dealer Never do it by yourself Make sure that a separate power supply circuit is provided for this air conditioner...

Page 9: ...ON This button is used only by qualified service persons for maintenance purposes 17 PROGRAMMING TIME BUTTON Use this button for programming START and or STOP time hr hr C Refer to figure 1 on page 1...

Page 10: ...ile When the warm air stays under the ceiling and your feet are cold we recommend that you use a circulator a fan to circulate the air inside the room For details consult your dealer For programming T...

Page 11: ...g the timer Off and On at the same time repeat the above procedure from 1 to 3 once again When the timer is programmed to stop the system after 3 hours and start the system after 4 hours the system wi...

Page 12: ...sh and neutral detergent Remove water and dry in the shade NOTE Do not wash the air conditioner with hot water of more than 50 C as doing so may result in discol oration and or deformation Do not expo...

Page 13: ...AIR CONDITIONER The outdoor unit stops The room temperature has reached the preset temperature The indoor unit is in ventilation oper ation II THE AIR CONDITIONER STOPS OPERATING FROM TIME TO TIME Th...

Page 14: ...set tempera ture See page 6 The AIR FLOW BLADE display on the control panel differs in direction from the actual air flow blade While in heating operation The air conditioner will be in wind direction...

Page 15: ...heck if the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE 3 The system operates but it does not suffi ciently cool or heat If the air inlet or outl...

Page 16: ...3P170549 6F EM07A042A 0802 HT FS...