background image

8

English

ONLY A QUALIFIED SERVICE PERSON IS 
ALLOWED TO PERFORM MAINTENANCE

IMPORTANT!

• BEFORE OBTAINING ACCESS TO TERMINAL 

DEVICES, ALL POWER SUPPLY CIRCUITS 
MUST BE INTERRUPTED

To clean the air conditioner, be sure to stop oper-
ation, and turn the power switch off. Otherwise, an 
electric shock and injury may result.

Do not wash the air conditioner with water.
Doing so may result in an electric shock.

Be careful with a scaffold or staging.
Caution must be exercised because of work at a 
high place.

HOW TO CLEAN THE AIR FILTER

Clean the air filter when the display shows “

” 

(TIME TO CLEAN AIR FILTER).
Increase the frequency of cleaning if the unit is 
installed in a room where the air is extremely con-
taminated.
If the dirt becomes impossible to clean, change the 
air filter. (Air filter for exchange is optional)

1. Open the suction grille.

Slide it forward slowly.

Please!

Do not pull on the front panel. It opens only slightly.

2. Remove the air filters.

Pull the filter up and out carefully.

8. MAINTENANCE

(FOR SERVICE PERSONNEL)

3. Clean the air filter.

Use vacuum cleaner 

A)

 or wash the air filter with 

water

 B).

A)

Using a vacuum cleaner

B)

Washing with water
When the air filter is very dirty, 
use soft brush and neutral 
detergent.

Remove water and dry in the shade.

NOTE

Do not wash the air conditioner with hot water of 
more than 50°C, as doing so may result in discol-
oration and/or deformation.

Do not expose it to fire, as doing so may result in 
burning.

4. Reset the air filter in place.

After cleaning the filter, do not forget to put it 
back the way it was before.

5. Press the FILTER RESET button on the con-

trol panel.

The display “

” (TIME TO CLEAN AIR FILTER) 

vanishes.

HOW TO CLEAN AIR OUTLET AND OUTSIDE 
PANELS

Clean with soft cloth.

When it is difficult to remove stains, use a damp 
cloth with some water-diluted neutral detergent. 
Wlpe with a dry cloth afterwards.

NOTE

Do not use gasoline, benzene, thinner, polishing 
powder, liquid insecticide. It may cause discolor-
ing or warping.

Do not use water or air of 50°C or higher for clean-
ing air filters and outside panels.

START UP AFTER A LONG STOP

Confirm the following

Check that the air inlet and outlet are not blocked.
Remove any obstacle.

Check if the earth is connected.
Might there be a broken wire somewhere?
Contact your dealer if there are any problems.

Clean the air filter and outside panels

After cleaning the air filter, make sure to attach it.

Turn on the main power supply switch.

The display on the control panel will be shown 
when the power is turned on.

To protect the unit, turn on the main power switch 
at least 6 hours before operation.

01_EN_3P170549-6F.fm  Page 8  Saturday, December 22, 2007  11:49 AM

Summary of Contents for FVQ71BV1B

Page 1: ...SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Floor standing type FVQ71BV1B FVQ100BV1B FVQ125BV1B English Deutsch Fran ais Espa ol Italiano Nederlands Portugues...

Page 2: ...ar en caso de aver a Despu s de leer el manual con s rvelo para consultas futuras La ringraziamo di aver acquistato questo con dizionatore d aria Daikin Leggere attentamente questo manuale prima di ut...

Page 3: ...AILABLE L H 2 10 11 3 1 4 5 6 7 8 14 15 16 17 18 19 20 21 22 12 9 13 NOTE Never operate remote controller buttons with hard pointed objects This may result in remote controller damage e a f d c i h e...

Page 4: ...eite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalaciones espe...

Page 5: ...S FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one control panel controls one indoor unit system Confirm th...

Page 6: ...r conditioner is to be installed in a small room it is necessary to take proper mea sures so that the amount of any leaked refriger ant does not exceed the concentration limit in the event of a leakag...

Page 7: ...not wash the air conditioner with water as this may result in electric shocks or fire Do not place water containers flower vases etc on the unit as this may result in electric shocks or fire Do not in...

Page 8: ...ring All wiring must be performed by an authorized electrician To do wiring ask your dealer Never do it by yourself Make sure that a separate power supply circuit is provided for this air conditioner...

Page 9: ...ON This button is used only by qualified service persons for maintenance purposes 17 PROGRAMMING TIME BUTTON Use this button for programming START and or STOP time hr hr C Refer to figure 1 on page 1...

Page 10: ...ile When the warm air stays under the ceiling and your feet are cold we recommend that you use a circulator a fan to circulate the air inside the room For details consult your dealer For programming T...

Page 11: ...g the timer Off and On at the same time repeat the above procedure from 1 to 3 once again When the timer is programmed to stop the system after 3 hours and start the system after 4 hours the system wi...

Page 12: ...sh and neutral detergent Remove water and dry in the shade NOTE Do not wash the air conditioner with hot water of more than 50 C as doing so may result in discol oration and or deformation Do not expo...

Page 13: ...AIR CONDITIONER The outdoor unit stops The room temperature has reached the preset temperature The indoor unit is in ventilation oper ation II THE AIR CONDITIONER STOPS OPERATING FROM TIME TO TIME Th...

Page 14: ...set tempera ture See page 6 The AIR FLOW BLADE display on the control panel differs in direction from the actual air flow blade While in heating operation The air conditioner will be in wind direction...

Page 15: ...heck if the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE 3 The system operates but it does not suffi ciently cool or heat If the air inlet or outl...

Page 16: ...3P170549 6F EM07A042A 0802 HT FS...

Reviews: