background image

English

1

CONTENTS

ILLUSTRATION.................................................. [1]

1. WHAT TO DO BEFORE OPERATION .......... 1
2. SAFETY PRECAUTIONS .............................. 1
3. OPERATION RANGE .................................... 4
4. INSTALLATION SITE .................................... 4
5. NAME AND FUNCTION OF EACH

SWITCH AND DISPLAY ON THE
CONTROL PANEL......................................... 4

6. OPERATION PROCEDURE .......................... 5
7. OPTIMUM OPERATION ................................ 7
8. MAINTENANCE

(FOR SERVICE PERSONNEL) ..................... 8

9. NOT MALFUNCTION OF THE AIR 

CONDITIONER .............................................. 9

10. TROUBLE SHOOTING ................................ 10

Important information regarding the refrig-
erant used

This product contains fluorinated greenhouse gases 
covered by the Kyoto Protocol.

Refrigerant type:R410A

GWP

(1)

 value:1975

(1)

 GWP = global warming potential

Periodical inspections for refrigerant leaks may be 
required depending on European or local legislation. 
Please contact your local dealer for more information.

This operation manual is for the following systems 
with standard control. Before initiating operation, 
contact your Daikin dealer for the operation that cor-
responds to your system.

If your installation has a customized control system, 
ask your Daikin dealer for the operation that corre-
sponds to your system.

Heat pump type
This system provides cooling, heating, automatic, 
program dry, and fan operation modes.

Straight cooling type
This system provides cooling, program dry, and 
fan operation modes.

1. WHAT TO DO BEFORE OPERA-

TION

Indoor unit

Outdoor unit

PRECAUTIONS FOR GROUP CONTROL 
SYSTEM OR TWO REMOTE CONTROLLER 
CONTROL SYSTEM

This system provides two other control systems 
beside individual control (one control panel controls 
one indoor unit) system. Confirm the following if your 
unit is of the following control system type.

• Group control system

One control panel controls up to 16 indoor units.
All indoor units are equally set.

• Two remote controller system

One control panel and one remote controller 
control one indoor unit (In case of group control 
system, one group of indoor units)
The unit is individually operated.

NOTE

Contact your Daikin dealer in case of changing 
the combination or setting of group control and 
two remote controller control systems.

 Refer to figure 2 on page [1] 

NOTE

The control panel lid opens to around 100 
degrees. Opening it further than that may cause it 
to break or come off the hinges.

To gain full advantage of the air conditioner’s func-
tions and to avoid malfunction due to mishandling, 
we recommend that you read this instruction manual 
carefully before use.
This air conditioner is classified under “appliances 
not accessible to the general public”.

Names and functions of parts

a

Indoor unit

b

Outdoor unit 

c

Control panel

d

Inlet air

e

Discharged air

f

Air outlet

g

Blade (at air outlet)

h

Refrigerant piping, connection electric wire

i

Drain pipe

j

Air inlet
The built-in air filter removes dust and dirt.

k

Ground wire
Wire to ground from the outdoor unit to pre-
vent electrical shocks.

2. SAFETY PRECAUTIONS

01_EN_3P170549-6F.fm  Page 1  Saturday, December 22, 2007  11:49 AM

Summary of Contents for FVQ71BV1B

Page 1: ...SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Floor standing type FVQ71BV1B FVQ100BV1B FVQ125BV1B English Deutsch Fran ais Espa ol Italiano Nederlands Portugues...

Page 2: ...ar en caso de aver a Despu s de leer el manual con s rvelo para consultas futuras La ringraziamo di aver acquistato questo con dizionatore d aria Daikin Leggere attentamente questo manuale prima di ut...

Page 3: ...AILABLE L H 2 10 11 3 1 4 5 6 7 8 14 15 16 17 18 19 20 21 22 12 9 13 NOTE Never operate remote controller buttons with hard pointed objects This may result in remote controller damage e a f d c i h e...

Page 4: ...eite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalaciones espe...

Page 5: ...S FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one control panel controls one indoor unit system Confirm th...

Page 6: ...r conditioner is to be installed in a small room it is necessary to take proper mea sures so that the amount of any leaked refriger ant does not exceed the concentration limit in the event of a leakag...

Page 7: ...not wash the air conditioner with water as this may result in electric shocks or fire Do not place water containers flower vases etc on the unit as this may result in electric shocks or fire Do not in...

Page 8: ...ring All wiring must be performed by an authorized electrician To do wiring ask your dealer Never do it by yourself Make sure that a separate power supply circuit is provided for this air conditioner...

Page 9: ...ON This button is used only by qualified service persons for maintenance purposes 17 PROGRAMMING TIME BUTTON Use this button for programming START and or STOP time hr hr C Refer to figure 1 on page 1...

Page 10: ...ile When the warm air stays under the ceiling and your feet are cold we recommend that you use a circulator a fan to circulate the air inside the room For details consult your dealer For programming T...

Page 11: ...g the timer Off and On at the same time repeat the above procedure from 1 to 3 once again When the timer is programmed to stop the system after 3 hours and start the system after 4 hours the system wi...

Page 12: ...sh and neutral detergent Remove water and dry in the shade NOTE Do not wash the air conditioner with hot water of more than 50 C as doing so may result in discol oration and or deformation Do not expo...

Page 13: ...AIR CONDITIONER The outdoor unit stops The room temperature has reached the preset temperature The indoor unit is in ventilation oper ation II THE AIR CONDITIONER STOPS OPERATING FROM TIME TO TIME Th...

Page 14: ...set tempera ture See page 6 The AIR FLOW BLADE display on the control panel differs in direction from the actual air flow blade While in heating operation The air conditioner will be in wind direction...

Page 15: ...heck if the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE 3 The system operates but it does not suffi ciently cool or heat If the air inlet or outl...

Page 16: ...3P170549 6F EM07A042A 0802 HT FS...