background image

9

English

ONLY A QUALIFIED SERVICE PERSON IS 
ALLOWED TO PERFORM MAINTENANCE

WARNING

• Do not use flammable gas (such as hair sprays 

and insecticides) near the air conditioner.

• Do not wipe the air conditioner with benzine or 

thinner.
It may cause cracks, electric shocks or a fire.

• Never put your fingers or rods in the air inlet, 

air outlet or horizontal blade. The fan is rotat-
ing at high speed, so you would get injured.

CAUTION

• Do not wash the air conditioner with water.

It may cause electric shocks or a fire due to 
leakage.

• Make sure to turn off the air conditioner when 

taking care of the air conditioner and discon-
nect the power supply breaker.
Unless the power supply is disconnected, it 
may cause electric shocks and injuries.

• When working at a high place, give caution to 

your footing.
If the scaffold is unstable, it may cause inju-
ries due to fall and stumbling.

NOTE 

• Do not remove the air filter unless for clean-

ing. It may cause failure.

• Do not attach substance (such as paper tow-

els) other than the specified air filter to the air 
inlet. The performance may drop and cause 
freeze-up/water leakage.

HOW TO CLEAN THE AIR FILTER

When the remote controller indicates “

” or “Time 

to clean filter”, clean the air filter.

It indicates after running for a certain time.

NOTE 

You may change the time of indication “

” or 

“Time to clean filter”.

If the indoor unit is used in a space where the 
air is more contaminated, ask your local 
dealer for solution.

8. MAINTENANCE

(FOR SERVICE PERSONNEL)

Contamination

Time until indication is 
displayed

Normal

2500 hours
(equivalent to one year)

More contami-
nated

1250 hours
(equivalent to a half year)

If it becomes difficult to remove contamination 
from the air filter, replace the air filter. 
(Air filter for replacement is an optional acces-
sory)

1. Open the suction grille.

Simultaneously slide the two knobs, slowly down 
the suction grille. 

2. Take out the air filter.

Carry out the work in the order mentioned below.

1

Pull the air filter end inclined downward and 
unhook the hooking hole of the air filter from 
the projection of the grille. (both right and left)

2

Lift the air filter and unhook the hooking hole 
of the air filter from the projection at the grille 
upper part. (both left and right) 

3. Clean the filter.

Clean the contamination with a vacuum cleaner 
or wash it with water. 

If the air filter is 
extremely con-
taminated, wash 
it with neutral 
detergent using 
a soft brush.

After dewater-
ing, dry the air 
filter in the 
shade.

Knob

Knob

Filter

Filter

Grille upper 
part projection

Projection

Filter

Air filter end

2

1

2

1 1

2

01_EN_3P170549-16W.fm  Page 9  Thursday, February 20, 2014  5:28 PM

Summary of Contents for FUQ100CVEB

Page 1: ...MANUAL MODELS 4 Way Blow Ceiling Suspended type SPLIT SYSTEM VRV SYSTEM FUQ71CVEB FXUQ71AVEB FUQ100CVEB FXUQ100AVEB FUQ125CVEB English Deutsch Fran ais Espa ol Italiano Nederlands Portugu s T rk e 00...

Page 2: ...rdelo para futuras consultas Asimismo aseg rese de entregar este manual de instrucciones a un nuevo usuario Debido a que este manual de instrucciones est dedi cado a la unidad interior deber consultar...

Page 3: ...tes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalaciones especial izadas para su r...

Page 4: ...es a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or modera...

Page 5: ...amount of any leaked refrigerant does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion CAUTION Children should be watched so...

Page 6: ...he control box fan motor drain pump etc make sure to shut off all power sup ply for the air conditioner including both indoor and outdoor units When cleaning the heat exchanger make sure to remove the...

Page 7: ...s a customized control system ask your local dealer for the operation that corre sponds to your system PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides...

Page 8: ...t bulb temperature The setting temperature range of the remote con troller is 16 C to 32 C 3 2 FXUQ Read the operation manual attached to the out door unit Regarding places for installation Istheairco...

Page 9: ...is used to prevent the dis charge of melt water The remote controller displays the fan speed that is set When the outdoor temperature is high it takes some time until the indoor temperature reaches th...

Page 10: ...r the indoor temperature and humidity first use the COOLING OPERATION to lower the indoor temperature and then use the PROGRAM DRY OPERATION When the indoor temperature is lowered airflow from the ind...

Page 11: ...conditioner It may decrease the effect or stop the operation Adjust the room temperature properly for a com fortable environment Avoid excessive heating or cooling Not doing so wastes electricity When...

Page 12: ...r filter It indicates after running for a certain time NOTE You may change the time of indication or Time to clean filter If the indoor unit is used in a space where the air is more contaminated ask y...

Page 13: ...ched to the indoor unit Refer to the figure shown below Suction grille Strap Knob Knob 2 Open the suction grille to 45 and lift it Then unhook it from the place to hook 3 places 3 Take out the air fil...

Page 14: ...order to activate the air condi tioner smoothly and to protect the air conditioner The display on the remote controller will be shown when the power circuit breaker is turned on HEATING OPERATION wit...

Page 15: ...installation but every time the power cir cuit breaker is turned off on 9 NOT MALFUNCTION OF THE AIR CONDITIONER For comfortable use do not turn off the power circuit breaker during seasonal use of t...

Page 16: ...unit Ask your local dealer for details on cleaning the indoor unit This cleaning requires a qualified service person Check the usage environment When the air conditioner is changed over to the HEATIN...

Page 17: ...vers 2 If the air conditioner stops after operating the air conditioner Check if the air inlet or outlet of outdoor or indoor unit is blocked by obstacles Remove the obstacle and make it well venti la...

Page 18: ...his time please tell the symptom and model name written on the model name plate If one of the following malfunctions occurs take the measures shown below and contact your local dealer The air conditio...

Page 19: ...3P170549 16W EM12A001A 1404 HT 00_CV_3P170549 16W_01 fm Page 2 Saturday February 15 2014 6 19 PM...

Reviews: