11
English
6. Attach the suction grille.
Attach the suction grille in the reverse order
mentioned in the clause 2.
7. Close the suction grille.
Simultaneously slide the 2 knobs in the reverse
order mentioned in the clause 1, slowly lift the
suction grille and securely fix it.
HOW TO CLEAN OUTSIDE PANELS AND
REMOTE CONTROLLER
•
Wipe them with a dry soft cloth.
•
When the stain cannot be wiped off, dip the cloth
in the neutral detergent diluted with water and
twist the cloth.
After wiping off stain with this cloth, wipe them
with dry cloth.
NOTE
• Do not use such as gasoline, benzine, thinner,
polishing powder and liquid insecticide sold
in the market.
It may cause discoloration and deformation.
• Do not wash them with warm water of 50°C or
higher.
It may cause discoloration and deformation.
CLEANING BEFORE AND AFTER SEA-
SONAL USE
WHAT TO DO WHEN START UP AFTER A
LONG STOP
Confirm the following.
•
Check that the air inlet and outlet of indoor and
outdoor unit are not blocked.
Remove any obstacle.
Obstacles decrease the fan speed, and cause
performance decrease and breakage of the
devices.
Clean the air filter.
•
After cleaning the air filter, make sure to attach it.
(Refer to
“8. MAINTENANCE”
on page 9.)
For information on how to install, remove, or clean
a optional sold air filter, refer to the user’s manual
attached to the air filter.
•
Turn off the indication “
” or “Time to clean fil-
ter” displayed on the remote controller after turn-
ing on the power.
•
For details, refer to the operation manual attached
to the remote controller.
The indication can be turned off whether in oper-
ation or at stop.
Turn on the power circuit breaker at least 6
hours before operation.
•
This is required in order to activate the air condi-
tioner smoothly, and to protect the air conditioner.
•
The display on the remote controller will be shown
when the power circuit breaker is turned on.
HEATING OPERATION within 6 hours after
power is supplied to the air conditioner.
Some model series perform the following operation
to protect the devices.
If the HEATING OPERATION is performed within 6
hours after power is supplied to the air conditioner,
the indoor fan stops for about 10 minutes during the
outdoor unit operation to protect the devices.
The above operation is performed not only for instal-
lation, but every time the power circuit breaker is
turned off/on.
For comfortable use, do not turn off the power circuit
breaker during seasonal use of the HEATING
OPERATION.
WHAT TO DO WHEN STOPPING THE AIR
CONDITIONER FOR A LONG PERIOD
Turn on FAN OPERATION for a half day on the
fine day and dry the indoor unit.
•
This can prevent the causes of mould.
Turn off the power circuit breaker.
•
During the power circuit breaker is turned on,
some watts of electricity is being used even if the
air conditioner is not operating.
Turn off the power circuit breaker for saving
energy.
•
The display on the remote controller will vanish
when the power circuit breaker is turned off.
Clean the air filter.
•
Be sure to replace the air filter to its original place
after cleaning.
(Refer to
“8. MAINTENANCE”
on page 9.)
For information on how to install, remove, or clean
an optional sold air filter, refer to the user’s manual
attached to the air filter.
NOTE
The inside of the air conditioner may become con-
taminated after several seasons of use, potentially
causing performance degradation and water leak-
age.
Ask your local dealer for details on cleaning the
inside of the indoor unit. This operation requires a
qualified service person.